Listing ID #3766209
Company Information
Ask for more detail from the seller
Contact SupplierFeatures
Applications : RISH Insu10 Analog-Digital Insulation and Continuity Tester is suitable for following
Power Supply
Note : Battery cells should not be left in the instrument which may remain unused for extended period of time.
Environmental conditions
Display : LCD display field (65 mm x 30mm) with analog indication and digital display and with display of unit of measured quantity and functions
Digital
Reference Conditions
Auto turn OFF : Meter turns off automatically, if any of the keys or the selector switch have not been activated for about 10minutes in insulation range and 5 minutes in other ranges.
Fuse 500 mA(F) / 440V H.B.C.10kAmin (32mm x 6mm)
Electrical Safety
Mechanical Design
Meas. Function | Range | Resolution | Accuracy +(...% of rdg + ...Digit | Overload value & duration |
---|---|---|---|---|
Insulation | 0.01 M to 0.99 MΩ | 10 KΩ (0.01 MΩ ) | +- 3% + 2D | 1200 Vrms 10 sec |
Resistance M- ohm | >1.0 M to 9.9 MΩ | 100 K Ω (0.1 MΩ) | +- 5% + 2D | |
U =50V, 100 V | >10 M to 99 MΩ | 1MΩ | +- 30 % | |
Insulation | 0.01 M to 9.99 M Ω | 10 kΩ (0.01 mΩ) | +- 3% + 2D | 1200 Vrms 10 sec |
Resistance M- ohm | >10.0 M to 99.9 M Ω | 100 KΩ (0.1 MΩ) | +- 5% + 2D | |
U =250V, 500 V, 100 V | >100 M to 999MΩ | 1 MΩ | +- 30 % | |
Low Ohms | 0 to 9.99 Ω | 0.01Ω at 210 mA | +- 3% + 2D | 1200 Vrms 10 sec |
>10 to 99.9 Ω | 0.1Ω at 21 mA | +- 5% + 2D | ||
Continuity | 0 to 9.99Ω | 0.01Ω at 210 mA | +- 30 % | |
>10 to 99.9 Ω | 0.1Ω at 21 mA | +- 3% + 2D | 1200 Vrms 10 sec | |
V AC/DC | 25V to 450V | 1 V | +- 2% + 3D | |
450V to 600V | 1 V | +- 3 % |