    50Hz &Plusmn; 5% Single Phase Energy Meter

    Price: rupee 400 - rupee 500 / Piece Get Latest Price
    • Minimum Order Quantity : 3 Piece
    • Sold By : Powertrac Meters and Transformers

    Product Specifications

    • Frequency50Hz ± 5%
    • Country of OriginIndia
    • Power Consumption≤ 0.5W
    • Temperature Range-10°C to +55°C
    • CommunicationRS-485, Modbus (optional)
    • DisplayLCD digital display
    • Max Overload1.5 x rated current (90A for 60A)
    • Humidity95% RH max (non-condensing)
    • Accuracy ClassClass 1 for kWh, Class 2 for kVARh
    • Current Range5-10A, 10-40A,10A - 60A
    • Voltage230V ± 20%
    • Supply TypeManufacturer, Exporter, Supplier, Trader
    Preferred Buyer From : All over the world

    Product Overview

    . General Specifications:

    •Standard Reference: IS 13779: 1999 (latest version) – “Static AC Energy Meters”.

    •Type: Single-phase, Multifunction Electronic Energy Meter.

    •Voltage Rating: 230V AC, Single-phase, 50 Hz ± 2% (standard operating voltage).

    •Current Range: 10A to 60A (direct connected).

    •Frequency Range: 50 Hz ± 5% (i.e., 47.5 Hz to 52.5 Hz).

    •Metering: Active energy (kWh), Reactive energy (kVARh), Apparent energy (kVAh), Power Factor, Current, Voltage, Frequency.

    •Accuracy Class: Class 1 or Class 2 (depending on the model) – Accuracy tolerance of ±1% or ±2% for active energy measurement.

    2. Electrical Characteristics:

    •Voltage: 230V, Single-phase, 50Hz.

    •Operating Voltage Range: 160V to 270V (tolerant to fluctuations).

    •Overload Capacity:

    oTypically, the meter can handle 1.5 times the rated current (e.g., 90A max for 60A rated meters) for a specified period, often 1 hour.

    •Starting Current: ≤ 0.004A (typically, this is the minimum current the meter can measure, under which it should register energy).

    •Rated Current: 10A to 60A (direct connected).

    3. Accuracy:

    •Active Energy (kWh): Class 1 (±1% for consumption measurement under load conditions).

    •Reactive Energy (kVARh): TypicallyClass 2 (±2% for measurement of reactive energy).

    •Power Factor Measurement: Typically within ±2% accuracy range.

    •Current and Voltage: Accuracy for measuring current and voltage is typically ±1-2% within the rated current and voltage range.

    •Frequency: Accuracy ±0.1 Hz.

    4. Display and Functionality:

    •Display Type: LCD (Liquid Crystal Display) for easy reading of the values.

    •Display Parameters:

    oEnergy (kWh, kVARh, kVAh)

    oPower Factor

    oCurrent (A)

    oVoltage (V)

    oFrequency (Hz)

    oMax Demand (if supported)

    oTime-of-Use (TOU) data (if supported).

    •Display Readings: Clear digital display of energy consumption, power factor, and other parameters.

    •Power Loss: Low power consumption of the meter for continuous operation, typically ≤ 0.5W for the meter.

    5. Communication & Remote Monitoring (Optional Features):

    •Communication Ports: RS-485, Modbus RTU, etc. (for remote reading and integration with Building Management Systems or SCADA).

    •Data Logging: Some multifunction meters provide logging for demand, load profiles, and time-of-use data.

    •Pulse Output: For external integration or data logging (optional in some models).

    6. Environmental and Durability Specifications:

    •Operating Temperature Range: -10°C to +55°C (for normal operation).

    •Storage Temperature Range: -40°C to +70°C.

    •Humidity: 95% RH max (non-condensing).

    •Protection Class: IP51 (or higher), dust and splashproof, depending on the design.

    •Mounting: Wall-mountable, typically with DIN rail mounting available for certain models.

    7. Meter Housing and Safety:

    •Material: Flame-retardant, UV-resistant plastic housing.

    •Tamper Detection: Anti-tamper seals and mechanisms, including reverse-phase detection and over-voltage protection.

    •Short Circuit Protection: Built-in protection against overload or short circuit in the event of wiring faults.

    •Phase Reversal Detection: Some models feature phase reversal detection for additional security.

    8. Compliance and Standards:

    •Compliance: IS 13779: 1999 (with updates, if applicable).

    •Verification & Calibration: The meters should be subject to factory calibration and verification against national or international standards (e.g., National Standards or Standards of Weights and Measures).

    •Certificate: The meter is usually issued with a verification certificate that certifies its calibration and accuracy under standard conditions.

    9. Other Features (Optional in Some Models):

    •Time-of-Use (TOU) Metering: For varying tariffs based on consumption at different times of the day.

    •Event Logging: Logging of fault conditions, power outages, and other significant events.

    •Real-time Data: Some multifunction meters support real-time monitoring of power usage, offering valuable insight for energy management.

    10. Installation and Operation:

    •Connection Type: Direct connection (no need for external current transformers unless exceeding rated current).

    •Installation Location: Suitable for indoor or outdoor installation (IP rating permitting).

    •Installation Guidelines: Proper mounting per manufacturer's instructions to ensure safety and accurate readings.

     

    Conclusion:

    These GTPs ensure the single-phase multifunction energy meter provides accurate energy measurement and meets industry standards for residential and small commercial applications. Always refer to the product's specific technical datasheet for finer details, as manufacturers may include additional features beyond the base standards.

    Would you like more detailed insights into how specific features work, such as time-of-use metering or communication protocols?

     


    Click Here To View Catalog


    Download Detail File : Click Here
    Interested in this product? Ask for more details & Latest Price from seller
    Send Inquiry

    Company Overview

    Manufacturer Of Digital Voltmeter, Resin Cast Wpl Current Transformer, Resin Cast Summation Current Transformer, Resin Cast Protection Current Transformer, Resin Cast Block 3 Phase Current Transformer, 3000-6000A Ring Type Moulded Case Current Transformers, 1600-3200A Ring Type Moulded Case Current Transformers, 800-1600A Ring Type Moulded Case Current Transformers, 500-800A Ring Type Moulded Case Current Transformers, 400-600A Ring Type Moulded Case Current Transformers, 200-300A Ring Type Moulded Case Current Transformers, PSQ-80 800A Square Current Transformer, 800-1000 A Resin Cast Rectangular Current Transformer, 800-1600 A Resin Cast Rectangular Current Transformer, 800-1000 A Resin Cast Ring Type Current Transformer.

    Ratings & Reviews

    Overall Rating
    4.5/5
    Reviewed by 30 Users Write a Review
    User Satisfaction
    100%
    Response
    100%
    Quality
    100%
    Delivery
    R
    Rahul Kumar | Saharanpur,
    | 08 Jun 2026
    A
    Ali | Nellore,
    | 02 Jun 2026
    S
    Sachin Nanaware | Solapur,
    | 27 May 2026
    Share your requirements for a quick response!
    Tell us what you need?

    Company Information

    • calendar Member Since 9 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 08AASHP7571F1ZJ
    • location Address Plot No. 92/252, Gokhle Marg, Agarwal Farm, Shipra Path, Mansarovar, Jaipur, Rajasthan, 302020, IN

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Looking for Single Phase Energy Meter?

    Quantity
    Boost Business
    Growth 10X Faster
    More Leads, More Buyers. More Growth.
    Sell on ExportersIndia

    More Products From This Seller

    Popular Categories

    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice