Listing ID #4370146
Company Information
Ask for more detail from the seller
Contact SupplierWe have various Types of electrical Actuators from MOTOCON INDUSTRIES have been developed specially for the quarter turn operation of small size Butterfly Valves, Ball Valves, Plug Valves and Dampers. We are provided with Three phase Actuator which considerably saves the cost of electrical hardware and other accessories.
Also as the actuators are installed directly on final control element and are provided with stall-duty motors, the units become completely maintenance free, that is Fit and Forget type. The units are supplied with all necessary features to operate the final control element in ON/OFF or modulating modes.
We are simple in design with compact in size and lighter in weight due to high grade Aluminium alloy Body & achieve low cost automation.
The MOTOCON technical team ensures every actuator is passed through diverse stringent quality tests. This helps the team maintain high standards consistently. Every phase of the actuator design, development and manufacturing involves professional scrutiny with utmost care. And hence, our customers avail motors with reliable, high performance, accuracy and smooth movement.
Electrical actuator basically consists of following basic units:
Ambient temperature : -20 Degree to +70 Degree.
Humidity : 30% to 95%
Supply Voltage |
Three phase 415 V +/-10%, 50 Hz +/-5%, also available in 24 V AC / 110 V AC Supply
|
Duty | S2-10 min, S4-30% - 1200 cycles/hour |
Self-locking | Self-locking facility of the actuators is provided by mechanical locking feature of worm & worm wheel mechanism. |
Local position Indicator | A continuous local mechanical position indicator is provided with actuator which always gives a faithful indication of actuator position independent of power supply. |
Adjustable mechanical | Two adjustable mechanical stoppers are provided with actuator in open & close stoppers direction. This feature gives backup safety to final control device. |
Auxiliary limit switches |
Maximum four numbers of micro limit switches for end position can be provided.
Type 1 NO + 1 NC change over contact, Contact rating: 10A 125 - 250 V AC. |
Intermediate limit |
Maximum two numbers of micro limit switches for intermediate end position can be switches provided.
Type 1 NO + 1 NC change over contact, Contact rating: 10A 125 - 250 V AC. |
Torque limit switches |
Maximum two numbers of micro limit switches for end positions can be provide
Type 1 NO + 1NC change over type, Contact rating: 10A, 125-250 V AC |
Feed back Potentiometer | A multi turn pot meter is used for 0-500 ohms out put feedback value |
Position controller | Field/Panel mounted having input signal: 4-20mA / 0-10 V Dc |
Position Transmitter | Actuator mounted having Input from actuator mounted Potentiometer & output will be 4-20 mA proportionate |
Remote position indicator | Panel mounted digital position indicator for 0-100% open indication |
Space heater | To prevent water condensation, the actuator are fitted with an anti condensation heater called as space heater, the latter can be connected to the AC or DC voltage of 230 V. |
Actuator Life |
10,000 cycle consists of normal 900 travel in both directions (ie.900 to open +900 to close). an average load of at least 30% of the rated torque. One start consist of a movement of at least 1% travel in both direction (as per EN standard.15714-2-2009)
Manufacturing Standards
|
Discription | Actuator Model | |||||||
---|---|---|---|---|---|---|---|---|
Model No | MOTO-AQT-10 | MOTO-AQT-20 | MOTO-AQT-30 | MOTO-AQT-40 | MOTO-AQT-50 | MOTO-AQT-60 | ||
Rated Output Torque (Nm) | 100 | 200 | 300 | 400 | 500 | 600 | ||
Operating Speed (Sec /90°) | 20/40/80 | 20/40/80 | 20/40/80 | 20/40/80 | 20/40/80 | 20/40/80 | ||
Working Stroke (Degree) | 90° | 90° | 90° | 90° | 90° | 90° | ||
Weight (Kg.) | 34 | 34 | 34 | 34 | 34 | 34 | ||
Degree of Protection (IP) | IP67 | IP67 | IP67 | IP67 | IP67 | IP67 | ||
Area of Operation | Safe | Safe | Safe | Safe | Safe | Safe | ||
MOTOR DATA | ||||||||
Type | S2-10 Min, S4-30%-1200 cycles/h | |||||||
Supply: Standard | Three Phase 415V AC | |||||||
Supply Frequency (Hz) | T50 +/-5 % | |||||||
Output watts (Watts) | 60 | 90 | 120 | 150 | 180 | 180 | ||
Nominal Current (Amp)(Min-Max) | 0.1-0.3 | 0.2-0.5 | 0.3-0.7 | 0.3-0.70 | 0.80-1.2 | 1.10-1.2 | ||
Class Insulation | F | F | F | F | F | F | ||
Ambient Temperature (° C) | -20°C to 70°C | -20°C to 70°C | -20°C to 70°C | -20°C to 70°C | -20°C to 70°C | -20°C to 70°C |