Process pressure : Refer to section "Operating conditions"
Humidity : < 98 % RH , condensing
Thermal response time, T50 : < 1.5 s , Ø4 mm,
< 6.1 s , Ø6 mm,
≤ < 7.6 s , Ø8 mm
Degree of protection (EN 60529) : IP 67
IP 69K , with appropriate cable
Pt100 accuracy class (EN 60751) : B (± 0.3 °C at 0 °C),
± (0.3 + 0.005 × t)°C,
A (± 0.15 °C at 0 °C),
± (0.15 + 0.002 × t)°C,
1/3 B (± 0.1 °C at 0 °C),
± 1/3 × (0.3 + 0.005 × t)°C,
1/6 B (± 0.05 °C at 0 °C),
± 1/6 × (0.3 + 0.005 × t)°C
Surface roughness wetted parts : Ra ≤ 0.8 µm
Process temperature : Refer to section "Operating conditions"
Sensor length : 20 … 3000 mm
With transmitter : 4 … 20 mA , 2-wire,
4 … 20 mA , 2-wire + HART®
Pt100 accuracy class (EN 60751) : B (± 0.3 °C at 0 °C),
± (0.3 + 0.005 × t)°C,
A (± 0.15 °C at 0 °C),
± (0.15 + 0.002 × t)°C,
1/3 B (± 0.1 °C at 0 °C),
± 1/3 × (0.3 + 0.005 × t)°C,
1/6 B (± 0.05 °C at 0 °C),
± 1/6 × (0.3 + 0.005 × t)°C,
Process temperature : Refer to section "Operating conditions"
Thermal response time, T50 : RTD element only-
≤ 1.0 s , conical sensor,
≤ 1.3 s , Ø3 mm,
≤ 2.5 s , Ø4 mm,
≤ 3.0 s , Ø6 mm,
Hygiene : FDA (21 CFR 177.2415)
3-A (74-07)
Vibration (sinusoidal) (EN 60068-2-6) : 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
Process pressure : Refer to section "Operating conditions"
EMC : EN 61000-6-2,
EN 61000-6-3,
EN 61326-1,
NE21
Features: Head mounting Rail Mounting Highly stable Analog design. Built in ‘cold junction compensation’ for Thermocouple. Linearization & 3rd wire compensation for RTD. Wide supply voltage range Compact & cost effective. Technical...
Specifications:- Input :- Pt-100RTD, 2 or 3 wire. Thermocouple. Output :- 2 wire 4 to 20 mA corresponding to defined input temperature range. Operating Voltage :- Normally 24VDC, can range from 12V to 36V. Basic accuracy :- 0.5% of FSD Change of...
Bringing you top quality Temperature Transmitters that are manufactured to precision using high grade material under our team of qualified engineers. Products manufactured by us are known for their durability and long life. Our products are always...
TEMPERATURE TRANSMITTER Series 4400-TX Features RTD / Th/C input Two wire system 12 - 36 V DC supply Reverse polarity protected With & without local indication 3 ½ digit LCD display optional Span - Zero adjustment provided externally Monitor...
We are a top-notch supplier of a temperature transmitter that is used for monitoring humidity and temperature levels. Known for its accurate readings and long service life our temperature transmitter is available at industry leading prices....