In fuel tanks, the fuel level sensors are used to make accurate measurements of the fuel level. At Jaycee Technologies, we are credited with being the most reliable and trusted fuel level sensor manufacturers in India. We are based in Pune and we offer fuel level sensors that...
We are offering speed transmitters to convert output of speed transducers to 4-20 ma form. Speed sensors frequency to 4-20 ma. Frequency to current converter is an ideal device for transmission of speed signals generated by devices like proximity switches. The pulses received...
We offers head mounted temperature transmitters for processing signals from rtd and thermocouples. These transmitters are small, sleek, reliable and accurate. The range of the transmitter is field programmable and can be easily programmed at site. Special models having pc...
How many Transmitter Device product listings are available in Pune?
In Pune, there are currently 90 Transmitter Device products listed, offering a wide options available for purchase.
Where can I find a Transmitter Device near Pune?
You can find Transmitter Devices around Pune, such as Bhosari, Shivane, Kondhwa. You can also use ExportersIndia to search for Transmitter Device suppliers in Pune.
What are some related categories to the Transmitter Device in Pune?
Some related categories to Transmitter Device in Pune include Field Mounted Transmitter, Ultrasonic Transmitters.
How many Pune-based Transmitter Device manufacturers are there?
There are many Transmitter Device manufacturers in Pune. You can explore ExportersIndia to find them and use filters to your search as per your specific requirements.
How many trusted sellers are available for Transmitter Device in Pune?
Trusted sellers for Transmitter Device in Pune include:
With transmitter : 4 … 20 mA , 2-wire,
4 … 20 mA , 2-wire + HART®
Sensor tube material : AISI 316L (1.4404)
Humidity : < 98 % RH , condensing
Without transmitter : 1 x Pt100, 4-wire,
1 x Pt100, 4-wire,
2 x Pt100, 2-wire
Pt100 accuracy class (EN 60751) : B (± 0.3 °C at 0 °C),
± (0.3 + 0.005 × t)°C,
A (± 0.15 °C at 0 °C),
± (0.15 + 0.002 × t)°C,
1/3 B (± 0.1 °C at 0 °C),
± 1/3 × (0.3 + 0.005 × t)°C,
1/6 B (± 0.05 °C at 0 °C),
± 1/6 × (0.3 + 0.005 × t)°C
Sensor length : 20 … 3000 mm
Explosion protection : ATEX II 1G Ex ia IIC T4/T5,
ATEX II 3G Ex nA IIC T4/T5,
Ex ia Simple apparatus, gas and dust
Thermal response time, T50 : < 1.5 s , Ø4 mm,
< 6.1 s , Ø6 mm,
≤ < 7.6 s , Ø8 mm
Surface roughness wetted parts : Ra ≤ 0.8 µm
Degree of protection (EN 60529) : IP 67
IP 69K , with appropriate cable
Long term stability : ≤ 0.1 % FSR/a , measuring range > 1 bar ≤ 1 mbar , measuring range ≤ 1 bar
Diagnostic data (acyclic) : Process temperature
Compensated temperature range : -40 … 85 °C
Cycle time : ≥ 2.3 ms
Max. measuring error : ± 0.1 % FSR, ,± 0.25 % FSR ± 0.5 % FSR Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio
Standard error of measurement (BFSL) : ± 0.04 % FSR ,± 0.1 % FSR ± 0.2 % FSR Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio
Explosion protection : ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb,
ATEX II 1D Ex ia IIIC T107 °C IP6X Da,
ATEX II 1G Ex ia IIC T4/T6 Ga
Max. measuring span : 1600 bar
Temperature coefficient : ≤ 0.03 % FSR/10 K , measuring span,
≤ 0.03 % FSR/10 K , zero point
Pressure type : Relative (gauged)
Long term stability : ≤ 0.1 % FSR/a
Max. measuring error : ± 0.1 % FSR,± 0.25 % FSR,
± 0.5 % FSR,Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
For turndown, multiply this value by the applied turndown ratio
The FF86 series air velocity transmitters were developed to obtain accurate measuring results over a wide range of velocities and temperature. High-quality hot film sensor elements based on cutting-edge thin film technology ensure maximum...
• Measuring ranges from 01+100 Pa to -1000/+2000 mbar (according to model, see "Configuration") • 0-10 V or 4-20 mA output, active sensor, power supply 24 Vac/Vdc (3- 4wires) or 4-20 mA output, passive loop, power supply...