My ExportersIndia

For Buyer

For Seller

For Help

Rectifiers & Electronics Pvt Ltd
gstGST : 07AAGCR4127A1ZT Verifiedwrite review Write a Review

Our Products

  1. Testing Equipment 17 Products available
  2. Measuring Instruments & Equipment 5 Products available
  3. Testing Equipments 5 Products available
  4. Transformers 5 Products available
  5. Electric Fittings And Components 3 Products available
  6. Generators 3 Products available
  7. Garden & Outdoor Furniture 2 Products available
  8. Electronic Components 2 Products available
  9. Battery Chargers 2 Products available
  10. Domestic Fans, AC & Coolers 1 Products available
  11. Voltage Stabilizer 1 Products available
  12. Wire Making Machines 1 Products available
  13. Electrical & Electronic Gadgets 1 Products available
  14. Earthing Electrodes 1 Products available
  15. Cables And Wire Accessories 1 Products available
  16. Salon & Beauty Equipment 1 Products available
  17. Others Products 25 Products available

Rectifiers & Electronics Pvt Ltd - Testing Equipment

We offer the best product range of High Voltage Breakdown Tester, Breakdown Type AC High Voltage Tester, AC High Voltage Test Sets - Breakdown Type, DC High Voltage Tester and Voltage Tester.

High Voltage Breakdown Tester

    Rectifiers Electronics High Voltage Breakdown Tester

    • nput Voltage–230V
    • Output Voltage –0-15KV up to 100mA as required.
    high Voltage breakdown testers are designed for testing LT equipment and Home appliances as per ISIEC standards. Even the smallest units are complete with all required accessories and features that are provided on the most advance high capacity unit. The unit is designed keeping safety as an utmost priority. It is suitable for application in Laboratories, manufacturing units and sites.
    View Complete Details

    Breakdown Type AC High Voltage Tester

    • ApplicationTesting Machine
    • Input Voltage230V
    • Output Voltage0-15KV up to 100mA as required.
    • PowerElectronic

    AC High Voltage Breakdown Test Set (0-15KV, up to100mA)

     

    Application – LT equipment and component manufacturer

     

     Overview

     

    AC high Voltage breakdown testers are designed for testing LT equipment and Home appliances as per IS/IEC standards. Even the smallest units are complete with all required accessories and features that are provided on the most advance high capacity unit. The unit is designed keeping safety as an utmost priority. It is suitable for application in Laboratories, manufacturing units and sites.

     

    Features

    • Light in weight.
    • Portable for any application.
    • Additional safety features for users.
    • Complete high voltage test facility instead of just breakdown facility.

     

    Standard Accessories

    • I/p Lead – 3meter
    • O/p Lead – 3meter

     

    Optional Accessories

    • HT Cable  if need extra more than 3meter.
    • Earthing lead.
    • Crocodile clamp
    • Dead man switch
    • Grounding rod
    • Hand Held HV Probe set

     

    Technical Specifications

    The unit will be housed in M.S Sheets housing and will be compete with the following:-

    • Input ON/OFF switch with fuse.
    • Input ‘ON’ Indicator
    • HT ON Push Button.
    • HT ON Indicator
    • Push Button to increase/decrease the output.
    • H.T. Probe Set With H.T. Cable
    • KV Meter Digital
    • mA Meter Digital
    • Tripping Selector with tripping @25%, 50%, 75% and 100%mAmps as range given
    • Digital Timer
    • Input Lead - 3 meter.
    • Output Lead – 3 meter.
    • Zero Start Interlock.
    View Complete Details
    AC High Voltage Test Sets - Breakdown Type

      AC High Voltage Test Sets - Breakdown Type

      • Input Lead3 meter
      • Output Lead3 meter
      AC high Voltage breakdown testers are designed for testing LT equipment and Home appliances as per ISIEC standards. Even the smallest units are complete with all required accessories and features that are provided on the most advance high capacity unit. The unit is designed keeping safety as an utmost priority. It is suitable for application in Laboratories, made units and sites.
      View Complete Details
      DC High Voltage Tester

        DC High Voltage Tester

        This equipment is used for testing the underground cable, large Generator, Motor Transformer capacitor etc as per IS specification. The unit comes equipped with digital meters, motorized controls, onetwo way computer interface, Emergency shut down and Optimum operator safety features. SPECIAL FEATURES Multiplier circuit for economy and better life. Multiple interlocks for human safety. Optional computer interface facility. Available unto 1000 kV and 1 Amps.
        View Complete Details
        Voltage Tester

          Rectifiers Electronics Voltage Tester

          Rectifiers & Electronics, Popularly known as 'RE', is the Pioneer Organization in the field of High voltage testing equipment such as AC/DC High Voltage Test Sets and Other Electrical High Voltage Test Equipment in INDIA. In the last 33 Years, Through Continuous Aspirations, 'RE' has earned the Goodwill of Quality Control Engineers and Research Scientists Through out the Country.
          View Complete Details
          AC High Voltage Breakdown Tester

            Rectifiers Electronics AC High Voltage Breakdown Tester

            • I/p Voltage380/400V, 50/60HZ AC supply
            • Scale :0-40A
            • CapacityUp to 3000KVA
            AC High Voltage High capacity testers are specially designed for testing cables, Generators, transformers and other high capacitive equipments as per National and International Standards. During manufacturing each unit is tested at multiple stages, thus ensuring consistency and best quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 3000kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in airoil, oil insulation, and pollution Test.
            View Complete Details
            AC Voltage Tester

              Rectifiers Electronics AC Voltage Tester

              • Voltage380/400V, 50/60HZ AC supply
              • O/p VoltageUp to 800KV and 4A
              AC High Voltage High capacity testers are specially designed for testing cables, Generators, transformers and other high capacitive equipments as per National and International Standards. During manufacturing each unit is tested at multiple stages, thus ensuring consistency and best quality.
              View Complete Details

              Stationary Type DC High Voltage Tester

              • Min. Order (MOQ)one Set(s)
              • Input Voltage220/230V or 380/400, 50HZ / 60HZ AC Supply
              • Output VoltageUp to 500kV
              • CapacityUp to 1000mA
              • Duty CycleContinous for Testing or 15 minutes at full load

              ‘RE’ DC High Voltage Test Set is used for testing cables, generators and other electrical equipments as per National and International specifications. The unit consist of variac, transformer , rectifier, condenser, bleeder, filter etc. All the components are housed in sheet metal housing or specially designed fiber glass housing which are coated with anti tracking paints.

               

              Features

              • Easy to operate.
              • Rugged and compact in construction
              • Full-wave voltage doublers circuit / Multiplier Circuit.
              • Zero start interlock and earth interlock
              • Meter accuracy +- 1% full scale
              • Air Cooled Units / Air and Oil Cooled units
              • Digital meters for easy readability.
              • High Voltage Surge protection.

               

              Standard Accessories

              • Discharge Rod with 10 meter Long Lead with Clamp.

               

              Optional Accessories

              • Dead Man Switch

              Technical Specifications

              ParametersDescription
              ControlType 1- The unit can be manual control for voltage variation and push button controlled for HT actuation.
              Type  2- The unit can be complete with on board digitized panel with or without computer connectivity.
              Type  3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
              MeteringThe metering can be provided via resistive voltage divider for direct HT voltage and current measurement
              Termination The negative and positive terminal  are brought out on suitable insulator. Positive and negative polarirty can be supplied on earth potential on request.
              ProtectionThe unit consist of fast acting DC relay which actuates instantaneously if the testing current goes beyond the preset level.
              The HV will not acuate if the variac is not at zero position ( To protect the transformer  against transient on HV side and to protect the operator)
              RectifierSilicon diodes with RC networks are used for rectifictaion in bridge or double or multiplier or half wave circuit.
              FilterA suitable cpacity filter is added to ensure that the ripple is less than 2%.



              View Complete Details

              Portable DC High Voltage Tester

              • Input Voltage220/230V 50HZ / 60HZ AC Supply
              • Output VoltageUp to 400kV
              • CoolingNaturally air cooled
              • MOQOne Sets

              Portable DC High Voltage Test Set is used for testing underground cable, generators, switchgear etc. for understanding the condition of current leakage / insulation condition at any given point. These are extremely light weight units designed for field operation (Substation, Power Projects, Remote sites etc.). The units are delivered in custom made carry boxes to endure rough and rugged transportation.

               

              Features

              • Easy to operate
              • Digital meters for easy readability.
              • High Voltage Surge protection 
              • Multiplier circuit for better life.

               

              Standard Accessories

              • 5 meter long shielded output cable with first sized clamp.
              • 5 meter long input AC flexible chord with plug.
              • Discharge Rod with 5 meter Long Lead with Clamp.
              • Housings of the set accommodate in itself HT and main lead and other accessories.

               

              Optional Accessories

              • Covers for high voltage male and female sockets.
              • Dead man switch
              • Foot  switch.

              Technical Specifications

              ParametersDescription
              ControlType 1- The unit can be manual control for voltage variation and push button controlled for HT actuation.
              Type  2- The unit can be complete with on board digitized panel with or without computer connectivity.
              Type  3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
              HT CableThe equipment is supplied with copper braided HT cable with HT plug and socket. The braiding remains on earth potential
              LT CableFor input supply 5meter long 3 core cable is provided
              Zero start interlockingThis is to ensure that HT shall not actuate if the voltage control knob is at zero position
              Earth InterlockingIf proper earth is not connected the HT will not actuate
              Auto Discharge ArrangementThe equiment consist of automatic cable dischrging arrangement
              SocketHT plug and socket has beed especially developed by RE with automatic earthing arrangement 
              MetermA meter and voltmeter are provided on HT side. The meters are fully protected against surges and spikes.
              Accuracy with in +1%
              Over Voltage ProtectionHT automtically trips in case of output voltage exceeds the preset level
              Surges and Spikes ProtectionDuring the testing surges or spikes are often generated due to short circuit. The equipment is fully protected againt these.



              View Complete Details
              High Voltage Testers

                Rectifiers Electronics High Voltage Testers

                • Input Voltage220/230V 50HZ / 60HZ AC Supply
                • Output VoltageUp to 400kV
                High Voltage Test Set is used for testing underground cable, generators, switchgear etc. for understanding the condition of current leakage insulation condition at any given point. These are extremely light weight units designed for field operation (Substation, Power Projects, Remote sites etc.). The units are delivered in custom made carry boxes to endure rough and rugged transportation. Easy to operateDigital meters for easy readability.High Voltage Surge protection Multiplier circuit for better life.
                View Complete Details

                AC High Voltage Spark Tester

                • I/p Voltage230/240 Volt 50 Hz. AC Supply, single phase
                • Test VoltageUp 50KV
                • Test Frequency50HZ
                • Dia. RangeUp to 150mm
                • Line Speed300 m/min.
                • KV MeterAnalog or Digital display as required.

                RE High voltage spark testers are designed for checking the quality of insulation coated wires for pin holes / weak insulation / exposed conductor during manufacturing at work floor.  The wire is passed through brass ball beads which carry high voltage. If any pin hole is detected in PVC, a spark develops and electro magnetic counter counts the fault. The spark tester is necessary for every cable manufacturing unit. Spark Testers can be used for high speed extruders and high speed Recoiling processes. The efficiency of Spark Tester is up to 95%.

                 

                Special Features

                • Designed for extruder and recoiling operations.
                • Height adjustable Electrode box
                • Compact size.
                • Built in safety features for operators
                • Easy to operate.
                • Recoiling shutdown as per operator setting.

                 

                Accessories

                • Exit point cable earthing
                • Cable supporting roll.

                Technical Specifications

                ParametersDescription
                Indicatora) LT ON
                b) HV ON
                c) HV OFF
                d) Fault (Audio & Visual)
                Fault CounterElectro-Mechanical / Digital (resettable)
                Protectiona)  Input Fuse
                b) Short circuit protected
                Duty Continous 
                ControlTrip or bypass available
                Electrode Box Length150 mm x 150mm x 350 mmlength
                Length beads path100 mm x 100 mm x 150 mm lengths




                View Complete Details
                High Voltage Spark Testers

                  High Voltage Spark Testers

                  • Dia. RangeUp to 150mm
                  • Line Speed300 m/min.
                  High voltage spark testers are designed for checking the quality of insulation coated wires for pin holes weak insulation exposed conductor during made at work floor. The wire is passed through brass ball beads which carry high voltage. If any pin hole is detected in PVC, a spark develops and electro magnetic counter counts the fault. Spark Testers can be used for high speed extruders and high speed Recoiling processes. The efficiency of Spark Tester is up to 95%.
                  View Complete Details

                  AC Insulation Tester

                  • I/p Voltage220/230V or 380/400V, 50/60HZ AC supply
                  • O/p VoltageUp 60KV and 100mA
                  • CapacityUp to 6KVA
                  • Timer0-9999 Sec./min. Digital

                  ‘RE’ AC HV Rubber testing set is used for Testing Rubber Mats. These sets are generally used in Electrical manufacturing Industry/Power Houses, Electrical Repair etc. where AC H.V. test set is suggest by BIS or IEC. During AC H.V. testing High current is generated due to capacitive loading. AC High voltage test equipments are designed for continuous use, for testing, and can withstand short circuit. Fault burning can also be provided if desired.

                   

                  Features

                  • Technologically advanced design that helped make proper use of space and minimize the size of the equipment.
                  • The equipment has been made so that it is very simple to operate, thus any person after learning once can operate it

                   

                  Standard Accessories

                  • Main Unit

                  Technical Specifications

                  ParametersDescription
                  Control1- The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation.
                  2-Selectror switch to select leakage current at 25%,50%,75% and 100% of the mA capacity required.
                  3- The unit can be microprocessor based complete with on board memory, printout facility, programmable features etc.
                  4- The unit can be PLC based complte with computer, HMI memory, printer etc. for operation.
                  MeteringVoltmeter : One Digital type connected on HT side to indicate the output voltage
                  Scale :  0-60 kV AC.
                  Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
                  Scale :  0-100mA 
                  Protection A fast acting DC relay will isolate the circuit when the current exceeds pre-set level.
                  InterlockingThe unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided
                  ConstructionAC High voltage test set consists of
                  1) Control panel cum Regulating Transformer cum High Voltage Transformer.
                  Control PanelConsist of :
                  LT ON Indicator , Push button to actuate HT, HT ON Indicator,Push button to deactuate HT, Fault Indicator (HT OFF Indicator), Push Button Switch to increase / decrease the output voltage, Tripping selector switch with tripping @ 10-15-20-25-30-35-40-50-60-70-80-90-100mA, Timer ON/OFF Switch, Switch for rate of rise @ 0.5kV/sec and 2kV/sec,  Timer Digital, Digital KV Meter, Digital mA Meter
                   
                  Regulating TransformerContinuously variable transformer which feeds 0-230 V, to the main HV transformer. The voltage is boosted in ratio with transformer design. No wave shape distortion will take place. One terminal of HT transformer is maintained at earth potential through CST terminal, the other Ht terminal is brought out on suitable H.T. Load.
                  Protection:  The protective circuit incorporated in this unit consist of the following :
                  A) Zero Start Interlocking
                  B) Over current relay with current selection
                  C) Cage door at top side
                  This prevents accidental start of unit after break down.
                  HV TransformerThe Main step up transformer is housed inside the body  supported with welded angle iron frame and the output has been brought out through  H.T.  Terminal.














                  View Complete Details
                  Cascaded AC High Voltage Tester

                    Cascaded AC High Voltage Tester

                    • I/p Voltage220/230V, 380/400V, 50/60HZ AC supply
                    • O/p VoltageUp 800KV and 400mA
                    • CapacityUp to 320KVA
                    • Timer0-9999 Sec./min. Digital

                    AC High Voltage High capacity testers are  specially designed for testing cables, Generators, transformers and other high capacitive equipments as per National and International  Standards. During  manufacturing each unit is tested at multiple stages, thus ensuring consistency and best  quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 3000kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in air/oil, oil insulation, and pollution Test.

                     

                    Features

                    • Light in weight
                    • Casted Wheel for easy movement
                    • Multiple safety locks for the operator
                    • Specially designed for field operation.

                     

                    Standard Accessories

                    • Interconnecting Control Cable.
                    • Discharge Rod.
                    • Audio Visual alarm indicator.
                    • Corona Shield

                     

                    Optional Accessories

                    • Output HV cable.
                    • Interconnecting / input power cable.
                    • Earthling lead.
                    • Canvas cover.
                    • LV Transformer Oil.

                    Technical Specifications

                    ParametersDescription
                    ControlMnaual / MotorizedThe unit can be manual/motorized control for voltage variation and push button controlled for HT actuation.
                    Digitized PanelThe unit can be complete with on board digitized panel with or without computer connectivity.
                    PLC BasedThe unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
                    MeteringVoltmeter : One Digital type connected on HT side to indicate the output voltage
                    Scale :  0-800 kV AC.
                    Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
                    Scale :  0-500mA
                    Applicable only for type -1
                    For type -2 and type 3 metering is self contained
                    Protection TrippingA fast acting DC relay will isolate the circuit when the current exceeds pre-set level.
                    OverloadThis is used as a  secondary protection  in case the input loads exceeds the preset value
                    OvervoltageThis is used as a  secondary protection  in case the output voltage exceeds the preset value
                    InterlockingZero Start InterlockThe unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided.
                    Earth InterlockIt ensures that HV will not actutae untill good earthing is not provided. 
                    TerminationThe HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
                    Control PanelThe control panel is designed for five unique purposes.
                    1 -Control
                    2- Measure
                    3- Protect (Active and Passive)
                    4- Tripping
                    5 -Annunciate   
                    HV TransformerThe transformers are designed and manufactured as per IS /IEC guidelines. Single /  Multiple stage stepup transformers are utilized  for achiving the desired voltage. The units are designed and manufactured using the  preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard.

                     











                    View Complete Details

                    Low Capacity AC High Voltage Tester

                    • Min. Order (MOQ)one Set(s)
                    • I/p Voltage220/230V or 380/400V, 50 or 60HZ AC supply
                    • O/p VoltageUp 800KV and 250mA
                    • CapacityUp to 200KVA
                    • Timer0-9999 Sec./min. Digital

                    AC High Voltage Low capacity testers are  specially designed for testing Insulators , CT’s PT’s ,   Low dielectric capacitive electrical equipment, transformers etc. as per National and International  Standards.  During  manufacturing each unit is tested at multiple stages, thus ensuring consistency and best  quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 200kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in air/oil, oil insulation, and pollution Test.

                     

                    Features

                    • Light in weight
                    • Casted Wheel for easy movement
                    • Multiple safety locks for the operator
                    • Specially designed for field operation.

                     

                    Standard Accessories

                    • Interconnecting Control Cable.
                    • Discharge Rod.
                    • Audio Visual alarm indicator.
                    • Corona Shield

                     

                    Optional Accessories

                    • Output HV cable.
                    • Interconnecting / input power cable.
                    • Earthling lead.
                    • Canvas cover.
                    • LV Transformer Oil.

                    Technical Specifications

                    ParametersDescription
                    ControlType 1- The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation.
                    Type  2- The unit can be complete with on board digitized panel with or without computer connectivity.
                    Type  3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
                    MeteringVoltmeter : One Digital type connected on HT side to indicate the output voltage
                    Scale :  0-800 kV AC.
                    Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
                    Scale :  0-500mA
                    Applicable only for type -1
                    For type -2 and type 3 metering is self contained
                    Protection Tripping   -  A fast acting DC relay will isolate the circuit when the current exceeds pre-set level.
                    Overload  - This is used as a  secondary protection  in case the input loads exceeds the preset value
                    Overvoltage -  This is used as a  secondary protection  in case the output voltage exceeds the preset value
                    InterlockingZero Start Interlock  -  The unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided.
                    Earth interlock- It ensures that HV will not actutae untill good earthing is not provided.
                    TerminationThe HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
                    Control PanelThe control panel is designed for five unique purposes.
                    1 -Control
                    2- Measure
                    3- Protect (Active and Passive)
                    4- Tripping
                    5 -Annunciate   
                    HV TransformerThe transformers are designed and manufactured as per IS /IEC guidelines. Single /  Multiple stage stepup transformers are utilized  for achiving the desired voltage. The units are designed and manufactured using the  preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard.















                    View Complete Details

                    High Capacity AC High Voltage Tester

                    • I/p Voltage380/400V, 50/60HZ AC supply
                    • CapacityUp to 3000KVA
                    • Timer0-9999 Sec./min. Digital
                    • MOQOne sets

                    AC High Voltage High capacity testers are  specially designed for testing cables, Generators, transformers and other high capacitive equipments as per National and International  Standards. During  manufacturing each unit is tested at multiple stages, thus ensuring consistency and best  quality. These instruments are air cooled, oil cooled or air & oil cooled combined as per design. The units have been manufactured up to 800kV and up to 3000kVA.The units have type of tests such as dry withstand, wet withstand, breakdown voltage in air/oil, oil insulation, and pollution Test.

                     

                    Features

                    • Light in weight
                    • Casted Wheel for easy movement
                    • Multiple safety locks for the operator
                    • Specially designed for field operation.

                     

                    Standard Accessories

                    • Interconnecting Control Cable.
                    • Discharge Rod.
                    • Audio Visual alarm indicator.
                    • Corona Shield

                     

                    Optional Accessories

                    • Output HV cable.
                    • Interconnecting / input power cable.
                    • Earthling lead.
                    • Canvas cover.
                    • LV Transformer Oil.

                    Technical Specifications

                    ParametersDescription
                    O/p VoltageUp to 800KV and 4A
                    Intgration of reactor after 100KVA,
                    Integartion of series and parallel reatcor after 1500KVA
                    ControlType 1- The unit can be manual/motorized control for voltage variation and push button controlled for HT actuation.
                    Type  2- The unit can be complete with on board digitized panel with or without computer connectivity.
                    Type  3- The unit can be PLC based complete with computer, HMI memory, printer etc. for operation.
                    MeteringVoltmeter : One Digital type connected on HT side to indicate the output voltage
                    Scale :  0-800 kV AC.
                    Ammeter : One Digital type ammeter Connected on earth side to indicate the leakage Current on sample under test.
                    Scale :  0-40A
                    Applicable only for type -1
                    For type -2 and type 3 metering is self contained 
                    Protection Tripping   -  A fast acting DC relay will isolate the circuit when the current exceeds pre-set level.
                    Overload  - This is used as a  secondary protection  in case the input loads exceeds the preset value
                    Overvoltage -  This is used as a  secondary protection  in case the output voltage exceeds the preset value
                    InterlockingZero Start Interlock  -  The unit will have zero start interlocking to avoid the transients on HV transformer and provision for  cage door interlocking shall also be provided.
                    Earth interlock- It ensures that HV will not actutae untill good earthing is not provided.
                    TerminationThe HT output on suitable HT insulator and other point at earth potential will be brought out on suitable insulator
                    Control PanelThe control panel is designed for five unique purposes.
                    1 -Control
                    2- Measure
                    3- Protect (Active and Passive)
                    4- Tripping
                    5 -Annunciate   
                    ReactorA Parallel / series  reactor (LT and HT) when provided in the system resonates with the capacitive current generated during the dielectric testing of any component / equipment / system. It generally consist of motorised moving coil and fixed reactor. It operates up to a Q-factor of 20.
                    HV TransformerThe transformers are designed and manufactured as per IS /IEC guidelines. Single /  Multiple stage stepup transformers are utilized  for achiving the desired voltage. The units are designed and manufactured using the  preeminent material from India and Abroad. The coils are vacuum impregnated and insulated with High Quality EHV Grade transformer oil as per relevant IS and IEC Standard.
















                    View Complete Details
                    Tell Us What are you looking for? Will call you back

                    Contact Us

                    • icon userMr. Manish Arora(Rectifiers & Electronics Pvt Ltd)
                    • location icon10/3 Dlf Ind Area Moti Nagar, Delhi - 110015
                    • share iconShare us via
                    • Manufacturers In Delhi