  1. Data Loggers 4 Products available
  2. Computer Hardware & Peripherals 3 Products available
  3. Flow Meters 3 Products available
  4. Signs 2 Products available
  5. Scanners 2 Products available
  6. Monitor Accessories 2 Products available
  7. Calibrators 2 Products available
  8. Data Converters 1 Products available
  9. Gates 1 Products available
  10. Measuring Instruments & Equipment 1 Products available
  11. Inverters, UPS & Converters 1 Products available
  12. Electronic Components 1 Products available
  13. Sensors 1 Products available
  14. Others Products 4 Products available

Signs

Our Complete range of products are Digital Process Indicator / Controller, Hart to Modbus Indicator and Flow Indicator.

Digital Process Indicator / Controller

DPC 965M is 7 segment LED, 5 digit process value with 1/2 inch Display Size.It is intended to be used for indication and control application. Digital Indicator Controller accepts commonly used signal in process industry or 0 to 10VDC or RTD Pt100. In case of other inputs we can provide appropriate converters. Serial port RS 485 with MODBUS RTU protocol gives the user facility to connect the unit on all standard SCADA and DCS. 4-20mA Retransmission output for remote display or PLC can be provided for 4-20mA input type. 2 / 4 relays outputs are available. Ideal for SCADA applications.

View Complete Details

Hart To Modbus Indicator

  • Supply 230Volt AC
  • Input Hart
  • Output RS485
  • COMMUNICATION SETTINGS 8 way DIP switch for baud rates from 9600, 19200, 38400, 57600 & station ID from 1 to 64 for MODBUS side.
  • NO OF SLAVES 15 HART slave units

HMI, HART to MODBUS Indicator is designed to accept HART signals from field instruments in multi drop mode and convert standard variables into fixed MODBUS address registers. This is useful to accept / read exact values available for Flow, Pressure, Temperature transmitters in digital form in the control room eliminating errors in Analog input acquisition and process systems. User friendly messages to understand status of the instrument and actual values of HART slaves connected on the loop.The engineering units are acquired from the HART slaves hence reduced efforts for programming. User selectable baud rate for MODBUS Master on DIP switch. Isolated HART and RS485 port is available.

Technical Specifications
Supply 230Volt AC
Input Hart
Output RS485
COMMUNICATION SETTINGS 8 way DIP switch for baud rates from 9600,19200,38400, 57600 & station ID from 1 to 64 for MODBUS side.
NO OF SLAVES 15 HART slave units
MODBUS RTU On MODBUS RTU (Master) HMI gives Floating point value of Current, Primary, Secondary, Third & forth Variables. Engineering units for 4 variables & Device information like device ID, MFR'S code,hardware, software version etc. for HART slave units. (maximum 15). HART slave status indication in MODBUS registers