Min. Order (MOQ)
1 Piece(s)
We offer Relay Control System use full for control labs. In the present unit a simulated second order system is controlled by an electronic relay. Apart from a study of the relay characteristics the experiment introduces the concept of Describing Function. Finally the phase plane method of analysis is covered in detail where the switching trajectories can be displayed on an X-Y oscilloscope. >>Highlights System with electronic relayAdjustable hysteresis and dead zoneDisplay phase plane diagram on CROStability study by describing function method >>Experiments Study of the relay characteristics and display of the same on CRO for different values of hysteresis and dead zones.Study of the effect of hysteresis on system stability. Graphical analysis to predict sustained oscillations.Phase plane analysis of relay control system for various values of Hysteresis and Dead Zones. View the trajectory for different hysteresis and dead zone. >>Features and Specifications Simulated electronic relay using high speed ICsSimulated 2nd order linear plant. Facility for displaying x and x. signalsDead zone variable from 0-600mV Hysteresis variable from 0-500mV Built-in signal sources Sine and Square Amplitude: 0-1V (min.)Variable Frequency: 10, 20, 40, 80, 100, 200, 400, 800 and 1000Hz IC regulated internal power suppliesLiterature and patch cords includedAccessory - a dual beam CRO The experiment is complete in all respect, except a CRO.