Our Products
We are leaders in the market for providing best range of Saybolt Viscometer, Standard Tar Viscometers and Cannon Fenske Viscometer
AIM 529-1
\nRef. Standards – ASTM D88, D244, AASHTO T72
For the empirical measurement of Saybolt Viscosity of petroleum products at specified temperatures between 70°F and 210°F. This is also used for determining the Saybolt Furol viscosity of bituminous materials at temperatures of 250, 275, 300, 350, 400 and 450°F. It comprises one each of Cylindrical Oil Cup, Universal Tip, Furol Tip, Bath fitted with immersion heater mounted on a stand, Dimmerstat for temperature control, Stirrer with shield. Apparatus is supplied complete with insulated handle and thermometer support, receiving flask, withdrawal tube, filter funnel, thermometer support for cup and circular spirit level.
Suitable for operation on 220 V, 50 Hz, Single Phase, AC Supply.
\n\nOrdering Information:\nAIM 529-1 – Saybolt Viscometer with two cups - Digital
\nAIM 52910 – ASTM Thermometer Type 17F, Range: 66°F to 80°F
\nAIM 52911 – ASTM Thermometer Type 18F, Range: 94°F to 108°F
\nAIM 52912 – ASTM Thermometer Type 19F, Range: 120°F to 134°F
\nAIM 52913 – ASTM Thermometer Type 20F, Range: 134°F to 148°F
\nAIM 52914 – ASTM Thermometer Type 21F, Range: 174°F to 188°F
\nAIM 52915 – ASTM Thermometer Type 22F, Range: 204°F to 218°F
\nAIM 52918 – ASTM Thermometer Type 77F, Range: 245°F to 265°F
\nAIM 52919 – ASTM Thermometer Type 78F, Range: 295°F to 315°F
\nAIM 52917 – ASTM Thermometer Type 79F, Range: 345°F to 365°F
\nAIM 52919 – ASTM Thermometer Type 80F, Range: 395°F to 415°F
\nAIM 52920 – ASTM Thermometer Type 81F, Range: 445°F to 465°F
\n\n
AIM 52901 – Brass Oil Tube
\nAIM 52902 – Receiving Flask 60 ml
\nAIM 52903 – Universal and Furol Tip (set of 2)
\nAIM 52904 – Filter Funnel
\nAIM 52905 – Thermometer Support
\nAIM 52906 – Heating Coil
\nAIM 531 & 533
\nRef. Standards – IS:1206, IP 72, STPTC. RT2, RT3, BS:2000, (Part 72)
\nFor determining the viscosity of cut back bitumen and road oil. The viscometer consists of a chrome plated copper bath, with a drain valve and a central tube to receive the test cup and to position the stirrer, and is mounted on a stand with levelling feet. Stirrer has a curved shield and is provided with an insulated handle, thermometer socket and swivel support for the valve.
AIM 532, AIM 532-1, & AIM 532-2
\nRef. Standard: IS 1206 (II) & IS 1206 (III)
\nCannon Manning Viscometers are designed for the determination of the absolute viscosity of bitumen & cutbacks by a vacuum capillary method at specified temperatures.
Cannon Fenske Viscometers are designed for the determination of the kinematic viscosity by a vacuum capillary method.
Various types of Glass capillary Viscometers are used to measure viscosities because no single capillary Viscometer is ideally suited for all viscosity determinations.
\nSuitable for operation on 220 V, 50 Hz, Single Phase, AC Supply.
\n\nFeatures (Technical Specifications)\n(a) Cannon-Manning Viscometer:\n
Used for the measurement of absolute viscosity of highly viscous materials
\nViscometers of sizes 12 & 13
\nApplicable to materials of viscosities in the range of 360 to 8000 poise
\n(BS U Tube modified reverse flow Viscometer):
\nGenerally used for the measurement of kinematic viscosity of transparent or translucent liquids
\nViscometer of size 6 with direct flow range of 60 to 100 cSt
\nViscometer of size 7 with direct flow range of 180 to 3000 cSt
\nCannon – Manning Capillary tubes of sizes 12 & 13
\nCannon – Fenske Capillary tubes of sizes 6 & 7
\nKinematic Viscometer Bath with a provision for 6 tests
\nVacuum system
\nThermometer of IP-5C: range from –2 to 300°C (as per specification)
\nThermometer IP–64C: range from –20 to 102°C (0.2° resolution)
\n