Our Products
Description
The Cylinder mounted vacuum type gas chlorinator SM-117 is designed for assuring safety & Space saving Chlorinator, consist of vacuum regulator, rotameter, flow control valve, Yoke clamp to connect directly on cylinder A gas filter, a injector assembly vent & vacuum tubing of 5 meters.
Principle of Operation
Water Under pressure passes through injector cause vacuum, which open spring loaded diaphragm check valve. Vacuum passes through vacuum tubing to the chlorinator When cylinder/Tonner valve open chlorine passes through self aligned yoke gas filter where foreign particles are removed if present, chlorine gas passes to regulator where the cylinder pressure is controlled by the inlet valve assembly When vacuums adjusted by control valve vacuum opened the inlet valve with the help of diaphragm assembly and allowed chlorine gas to passes through flow meter where flow can be adjusted an to injector & point of application. If any break in the vacuum line occur the system automatically shut off the chlorine gas supply.
Material Of Construction
Totally non corrosive materials are used in chlorinator such as UHMWHDPE, PTFE (Teflon), monal, PVC, Borosilicate Glass, Hastelloy "C", PVDF, VITON etc
SM 207 SMPC Chlorinator needs water line pressure of 4 kg /cm2 to feed in gravity way otherwise booster pump is required as per site condition |
Areas of Application
Installation Offerings
Description
The SM 108 Model SBM Chlorinator is designed for Continuous & constant flow of Chlorine / Sulphur dioxide or Ammonia Gas in fully vacuum mode, designed with vacuum controller chamber, flow meter, gas flow control valve, Chlorine / Water pressure gauges, a gas filter, a injector to connect motive water, and point of application.
Installation Offerings
In SM-108 Model the Chlorinator is operated under vacuum .The vacuum created in the injector by water pressure passes through PVC piping / tubing to the vacuum regulator chamber via control valve Gas from Cylinder / Tonner passes through PVC coated copper tubing & enters a gas filter assembly where moisture and foreign particles are removed and send to differential vacuum regulator. Here, the diaphragm assembly dislocates inlet valve with the help of vacuum on one side, atmosphere pressure on the other and allows the gas to flow through flow meter via control valve where the flow rate of gas can be adjusted manually.
The gas passes to the injector where it is mixed with water in the mixing chamber and the solutions is discharged to the point of applications. If the water supply to the injector fails or any block in vacuum the inlet valve inside vacuum regulator assembly immediately isolates the gas under pressure and stops the flow of gas even though the cylinder valve is open and the gas inside the system is exhausted through the vent via relief valve.
Areas of Application
Description
The SM 207 Model SMPM Chlorinator is designed for Continuous & constant flow of Chlorine / Sulpherdioxide or ammonia Gas in fully vacuum mode, also designed with differential vacuum controller chamber, flow meter, gas flow control valve, Chlorine / Water pressure gauges, vacuum gauges and gas filter, also an injector to connect motive water and point of application.
Flow Meter Ranges
Principle of Operation
In SM-207 Model SMPM Chlornator is operated under vacuum. The vacuum created in the injector by water pressure is passed through PVC piping / tubing to the Differential vacuum regulator Chamber via control valve.
Gas from Cylinder/Tonner passes through PVC coated copper tubing & enters a gas filter assembly where moisture and foreign particles are removed and send to differential vacuum regulator. Here, the diaphragm assembly dislocates inlet valve with the help of vacuum on one side, atmosphere pressure on the other and allows the gas to flow through flow meter via control valve where the flow rate of gas can be adjusted manually.
The gas passes to the injector where it is mixed with water in the mixing chamber and the solutions is discharged to the point of applications. If the water supply to the injector fails or any block in vacuum the inlet valve inside vacuum regulator assembly immediately isolates the gas under pressure and stops the flow of gas even though the cylinder valve is open and the gas inside the system is exhausted through the vent via relief valve.
Areas of Application
Installation Offerings
When one manifold or tonner get empty the ADCOP switch over from an empty container to a full one with out interruption of chlorine flow with the help of control panel and a 3-way motorised ball valve.
A versatile sampling system for detection at a Particular Point or location
This apparatus is equipped with a cylinder containing compressed oxygen or air which can be strapped on to the body of a user or with a canister which produces oxygen chemically when the reaction is triggered. This type of equipment is suitable for high concentration of chlorine in an oxygen deficient atmosphere.
It consists of various tools and appliances like gaskets, yokes, studs, tie rods hoods, clamps, spanners, mild steel channels, screws, pins, wooden pegs etc. of standard sizes. Separate kits are used for cylinders and tonners. All the gadgets are designed for using in controlling or stopping the leakages from valves, fusible plug and side walls of cylinders and containers used for handling chlorine.
The chlorine gas leakage absorption is a safety device which reduces the risk of chlorine gas spreading into atmosphere from 100 kg cylinder or from 900 kg ton containers to absorb in caustic solution creating hypo chlorine and can be reused or use as cleaning agent. This system consists of a blower, an alkali (NaOH) tank, an absorption tower packed with rasching rings, alkali circulation pump, piping valves, light weight FRP and PVC duct. In the event of leak which is uncontrollable with emergency kit this system would allow the person to breathe easily rather than panic. In this system, the leak is confined by hood covering the leaking container, sucking the chlorine by blower and delivering it to absorption tower. Chlorine leak absorption capacity of the system is kept 100 kg/hr & 200 kg/hr for 100 kg cylinder and 900 kg tonner respectively.
Cylinder Keys, Copper Tubes, Clamps, Connectors, Valves
Both, Chlorine cylinders as well as Tonners valves are available conforming to IS:3224
A versatile system for boosting the flow of chlorine gas when ever the requirement of chlorine gas is more.