Hot Air Oven

  • Chamber Size :  12 x 12 x 12 (LBH in inches) to 12 x 12 x 12 (LBH in feet), user defined
  • Chamber Construction :  Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
  • Temperature Range :  Ambient to 100oC / 150oC / 200oC / 250oC / 300oC / 350oC / 400oC
  • Temperature Control :  Thermostate, On/Off, PI, PID, Microprocessor
  • Air Cirulation :  With or without air circulation

Model Number: SSI 551

SSI Ovens are designed to maintain uniform Temperature across the complete chamber and provide controlled enviroment for Heating, Curing, Drying or testing various properties under elevated temperature.

Chamber Size : 12 x 12 x 12 (LBH in inches) to 12 x 12 x 12 (LBH in feet), user defined
Chamber Construction : Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
Temperature Range : Ambient to 100oC / 150oC / 200oC / 250oC / 300oC / 350oC / 400oC
Temperature Control : Thermostate, On/Off, PI, PID, Microprocessor
Air Cirulation : With or without air circulation
View Complete Details

Hot Water Bath

  • Temperature Range :  Ambient to 100oC
  • Chamber Size :  12 x 12 x 12 (LBH in inches) to 4 x 4 x 4 (LBH in feet), user defined
  • Chamber Construction :  Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
  • Temperature Control :  Thermostate, On/Off, PI, PID, Microprocessor
  • Water Cirulation :  With or without water circulation
  •  Voltage: :  Single Phase 220V 50 Hz / 110V 60 Hz or Three Phase 440V
  •    
  • Delivery : 2 to 8 weeks based on Model Packing : Wooden Box

Model Number: SSI 107

SSI Hot Water Bath are designed to maintain uniform Temperature across the complete chamber and provide controlled enviroment for Heating, Curing, or testing various properties under elevated temperature of water.

Construction
SSI Hot Water Bath are sturdy, with double walled construction. Inner chamber made of STAINLESS STEEL sheet. Outer chamber is made of stainless steel or galvanized steel or mild steel sheet and are duly powder coated.
The gap between the walls is filled up with special grade glass wool for proper insulation to avoid heat losses.
Temperature Control

Thermostat (Temperature accuracy +/- 3 Deg C)On/Off Control (Temperature accuracy +/- 2 Deg C)PID Control (Temperature accuracy +/- 1 Deg C)Microprocessor control (Temperature accuracy +/- 0.5 Deg C

Please specify the kind of controller and accuracy required at the time of ordering.

Water Circulation
Water circulation using separate motor or stirrer.
Elements
Heating elements are made of high quality heaters which are put inside the water bath and placed at the bottom of the bath
Control Panel
Comprising of switch to ON/OFF the power, rotary switch to select high or low rates of heating, thermostat control knob and indicators for mains and thermostats. Supplied with cord and plug.
View Complete Details

Air Oxygen Pressure Chamber (HMI / PLC Model)

  • Chamber Size :  150mm (Dia) x 300mm (Height)
  • Chamber Construction :  Doubled Walled, Inner Chamber of 8-10 mm  wall thickness Seamless pipe. Outer MS / GI.
  • Heating :  Dry heating using Jacket Heater
  • Temperature Range :  Ambient to 200oC, LC 0.1oC
  • Temperature Control :  Digital PID Controller, +/- 1-2oC
  • Pressure :  0 to 22 kg/cm2,  LC 0.1 kg/cm2
  • Pressure Control :  Using Digital indicating Controller
  • Safety :  4 Layered Safety for over pressure and leakage protection. 
  • Display : All parameters are displayed on Touch Screen HMI
  • Control : The instrument is controlled using PLC. The pressure input and output are also controlled using PLC
  •    
  • Packing : One wooden Box
  • Delivery  : 4 to 6 Weeks

Model Number: SSI 519 AOPCH

Standard Number: IS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 - 1984, IEC 60811-1-2

The Instruments is used forheat Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Instrument Principle

The instrument is manufactured for Thermal Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Temperature Range: Ambient to 200oC

Pressure Range: 0-22 Kg/cm2(0-2.2 Mpa)

.Standard

The instrument conforms toIS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 1984 and IEC 60811-1-2

Instrument

The instrument consist of the following :

Inner chamber of seamless steel pipe of at least 6 mm thickness

SS lid and provision for placing the rubber test pieces,

Pressure Control by Digital Pressure Controller

Jacket Heaters outside the Inner Chamber

PID Digital Temperature Indicating Controller , least count 0.1oC

Pressure Gauge Digital (least count 0.1 kg/cm2, )

Inlet, outlet for Air and Oxygen with Solenoid Valves to control the flow

Safety valve (preset / sealed at 25 kg/cm2)

Unique Feature : If the pressure drops very rapidy, the syetem automatically shuts of input valve isolating the cylinder.

Manifold with pressure switch, solenoid valve for compensating drop in pressure of gas from cylinders

Power cord, extra seal, rubber pipe to connect with cylinder

The sample is kept inside the pressure chamber under high temperature and pressure for the desired time period. After the time period is over, the sample is tested visually for any creaks or deformations and also physical test are preformed like tensile and elongation to determine the change as a result of ageing.

Safety Feature

The Chamber is designed with four safety devices for over shoot of pressure.

a) The input is regulated by digital pressure control which switch off the solenoid value once the desired pressure is reached.

b) A separate pressure switch with solenoid value is provided in series with the first solenoid value. The value of this pressure switch is set slightly higher than the set value, and will cut off the pressure if the digital pressure control fails.

c) A release value is provided on the top, set at 25 kg/cm2 and will release the pressure if both the solenoid fails.

d) If the pressure drops very rapidly, the PLC assumes that either the gas is being released manually or there is some leakage. In both cases, the system shuts off the input valve and isolating the chamber form the gas cylinder. This prevents the wastage of gas and also provides protection in case of leakage.

View Complete Details

Air Oxygen Pressure Chamber

  • Chamber Size 150mm (Dia) x 300mm (Height)
  • Chamber Construction Doubled Walled, Inner Chamber of 8-10 mm wall thickness Seamless pipe. Outer MS / GI.
  • Heating Dry heating using Jacket Heater
  • Temperature Range Ambient to 200oC, LC 0.1oC
  • Temperature Control Digital PID Controller, +/- 1-2oC
  • Pressure 0 to 22 kg/cm2, LC 0.1 kg/cm2
  • Pressure Control Using Digital indicating Controller
  • Safety 4 Layered Safety for over pressure and leakage protection.
  • Display All parameters are displayed on Touch Screen HMI
  • Control The instrument is controlled using PLC. The pressure input and output are also controlled using PLC
  • Packing One wooden Box
  • Delivery 4 to 6 Weeks
  •    

Model Number: SSI 519 AOPC

Standard Number: IS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 - 1984, IEC 60811-1-2

The Instruments is used forheat Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygenair pressure.

Instrument Principle

The instrument is manufactured for Thermal Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Temperature Range: Ambient to 200oC

Pressure Range: 0-22 Kg/cm2(0-2.2Mpa)

Standard

The instrument conforms toIS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 1984 and IEC 60811-1-2

Instrument

The instrument consist of the following :

Inner chamber of seamless steel pipe of at least 6 mm thickness

SS lid and provision for placing the rubber test pieces,

Pressure Control by Digital Pressure Controller

Jacket Heaters outside the Inner Chamber

PID Digital Temperature Indicating Controller , least count 0.1oC

Pressure Gauge Digital (least count 0.1 kg/cm2, )

Inlet, outlet for Air / Oxygen

Safety valve (preset / sealed at 25 kg/cm2)

Manifold with pressure switch, solenoid valve for compensating drop in pressure of gas from cylinders

Power cord, extra seal, rubber pipe to connect with cylinder

The sample is kept inside the pressure chamber under high temperature and pressure for the desired time period. After the

time period is over, the sample is tested visually for any creaks or deformations and also physical test are preformed like tensile

and elongation to determine the change as a result of ageing.

Safety Feature

The Chamber is designed with three safety devices for over shoot of pressure.

a) The input is regulated by digital pressure control which switch off the solenoid value once the desired pressure is reached.

b) A separate pressure switch with solenoid value is provided in series with the first solenoid value. The value of this pressure switch is set slightly higher than the set value, and will cut off the pressure if the digital pressure control fails.

c) A release value is provided on the top, set at 25 kg/cm2 and will release the pressure if both the solenoid fails.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • S.S. Instruments Pvt. Ltd. (S.S. Instruments Pvt. Ltd.)
  • 209 Triveni Complax, E-10-12, Jawahar Park, Laxmi Nagar, Delhi – 110092., India
  • Share us via
  • Call 08068051399 Ext. 034
Retailer of Laboratory Equipments from Delhi, Delhi by S.S. Instruments Pvt. Ltd.
Post Buy Requirement

Laboratory Equipments #3689198

Hot Air Oven

  • Chamber Size :  12 x 12 x 12 (LBH in inches) to 12 x 12 x 12 (LBH in feet), user defined
  • Chamber Construction :  Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
  • Temperature Range :  Ambient to 100oC / 150oC / 200oC / 250oC / 300oC / 350oC / 400oC
  • Temperature Control :  Thermostate, On/Off, PI, PID, Microprocessor
  • Air Cirulation :  With or without air circulation

Model Number: SSI 551

SSI Ovens are designed to maintain uniform Temperature across the complete chamber and provide controlled enviroment for Heating, Curing, Drying or testing various properties under elevated temperature.

Chamber Size : 12 x 12 x 12 (LBH in inches) to 12 x 12 x 12 (LBH in feet), user defined
Chamber Construction : Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
Temperature Range : Ambient to 100oC / 150oC / 200oC / 250oC / 300oC / 350oC / 400oC
Temperature Control : Thermostate, On/Off, PI, PID, Microprocessor
Air Cirulation : With or without air circulation
View Complete Details

Hot Water Bath

  • Temperature Range :  Ambient to 100oC
  • Chamber Size :  12 x 12 x 12 (LBH in inches) to 4 x 4 x 4 (LBH in feet), user defined
  • Chamber Construction :  Double / Triple Walled, Inner and Outer Chamber of SS / GI / MS / Al, user defined
  • Temperature Control :  Thermostate, On/Off, PI, PID, Microprocessor
  • Water Cirulation :  With or without water circulation
  •  Voltage: :  Single Phase 220V 50 Hz / 110V 60 Hz or Three Phase 440V
  •    
  • Delivery : 2 to 8 weeks based on Model Packing : Wooden Box

Model Number: SSI 107

SSI Hot Water Bath are designed to maintain uniform Temperature across the complete chamber and provide controlled enviroment for Heating, Curing, or testing various properties under elevated temperature of water.

Construction
SSI Hot Water Bath are sturdy, with double walled construction. Inner chamber made of STAINLESS STEEL sheet. Outer chamber is made of stainless steel or galvanized steel or mild steel sheet and are duly powder coated.
The gap between the walls is filled up with special grade glass wool for proper insulation to avoid heat losses.
Temperature Control

Thermostat (Temperature accuracy +/- 3 Deg C)On/Off Control (Temperature accuracy +/- 2 Deg C)PID Control (Temperature accuracy +/- 1 Deg C)Microprocessor control (Temperature accuracy +/- 0.5 Deg C

Please specify the kind of controller and accuracy required at the time of ordering.

Water Circulation
Water circulation using separate motor or stirrer.
Elements
Heating elements are made of high quality heaters which are put inside the water bath and placed at the bottom of the bath
Control Panel
Comprising of switch to ON/OFF the power, rotary switch to select high or low rates of heating, thermostat control knob and indicators for mains and thermostats. Supplied with cord and plug.
View Complete Details

Air Oxygen Pressure Chamber (HMI / PLC Model)

  • Chamber Size :  150mm (Dia) x 300mm (Height)
  • Chamber Construction :  Doubled Walled, Inner Chamber of 8-10 mm  wall thickness Seamless pipe. Outer MS / GI.
  • Heating :  Dry heating using Jacket Heater
  • Temperature Range :  Ambient to 200oC, LC 0.1oC
  • Temperature Control :  Digital PID Controller, +/- 1-2oC
  • Pressure :  0 to 22 kg/cm2,  LC 0.1 kg/cm2
  • Pressure Control :  Using Digital indicating Controller
  • Safety :  4 Layered Safety for over pressure and leakage protection. 
  • Display : All parameters are displayed on Touch Screen HMI
  • Control : The instrument is controlled using PLC. The pressure input and output are also controlled using PLC
  •    
  • Packing : One wooden Box
  • Delivery  : 4 to 6 Weeks

Model Number: SSI 519 AOPCH

Standard Number: IS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 - 1984, IEC 60811-1-2

The Instruments is used forheat Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Instrument Principle

The instrument is manufactured for Thermal Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Temperature Range: Ambient to 200oC

Pressure Range: 0-22 Kg/cm2(0-2.2 Mpa)

.Standard

The instrument conforms toIS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 1984 and IEC 60811-1-2

Instrument

The instrument consist of the following :

Inner chamber of seamless steel pipe of at least 6 mm thickness

SS lid and provision for placing the rubber test pieces,

Pressure Control by Digital Pressure Controller

Jacket Heaters outside the Inner Chamber

PID Digital Temperature Indicating Controller , least count 0.1oC

Pressure Gauge Digital (least count 0.1 kg/cm2, )

Inlet, outlet for Air and Oxygen with Solenoid Valves to control the flow

Safety valve (preset / sealed at 25 kg/cm2)

Unique Feature : If the pressure drops very rapidy, the syetem automatically shuts of input valve isolating the cylinder.

Manifold with pressure switch, solenoid valve for compensating drop in pressure of gas from cylinders

Power cord, extra seal, rubber pipe to connect with cylinder

The sample is kept inside the pressure chamber under high temperature and pressure for the desired time period. After the time period is over, the sample is tested visually for any creaks or deformations and also physical test are preformed like tensile and elongation to determine the change as a result of ageing.

Safety Feature

The Chamber is designed with four safety devices for over shoot of pressure.

a) The input is regulated by digital pressure control which switch off the solenoid value once the desired pressure is reached.

b) A separate pressure switch with solenoid value is provided in series with the first solenoid value. The value of this pressure switch is set slightly higher than the set value, and will cut off the pressure if the digital pressure control fails.

c) A release value is provided on the top, set at 25 kg/cm2 and will release the pressure if both the solenoid fails.

d) If the pressure drops very rapidly, the PLC assumes that either the gas is being released manually or there is some leakage. In both cases, the system shuts off the input valve and isolating the chamber form the gas cylinder. This prevents the wastage of gas and also provides protection in case of leakage.

View Complete Details

Air Oxygen Pressure Chamber

  • Chamber Size 150mm (Dia) x 300mm (Height)
  • Chamber Construction Doubled Walled, Inner Chamber of 8-10 mm wall thickness Seamless pipe. Outer MS / GI.
  • Heating Dry heating using Jacket Heater
  • Temperature Range Ambient to 200oC, LC 0.1oC
  • Temperature Control Digital PID Controller, +/- 1-2oC
  • Pressure 0 to 22 kg/cm2, LC 0.1 kg/cm2
  • Pressure Control Using Digital indicating Controller
  • Safety 4 Layered Safety for over pressure and leakage protection.
  • Display All parameters are displayed on Touch Screen HMI
  • Control The instrument is controlled using PLC. The pressure input and output are also controlled using PLC
  • Packing One wooden Box
  • Delivery 4 to 6 Weeks
  •    

Model Number: SSI 519 AOPC

Standard Number: IS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 - 1984, IEC 60811-1-2

The Instruments is used forheat Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygenair pressure.

Instrument Principle

The instrument is manufactured for Thermal Ageing test under oxygen air pressure for insulation & sheath of electric cables. This apparatus is also used for estimating the relative resistance of vulcanized rubber to age determination by assessment of change in tensile strength & elongation of material by subjecting them to accelerated ageing in oxygen air pressure.

Temperature Range: Ambient to 200oC

Pressure Range: 0-22 Kg/cm2(0-2.2Mpa)

Standard

The instrument conforms toIS: 10810 (Pt.16), IS: 10810 (Pt.56), Appendix A of IS 6380 1984 and IEC 60811-1-2

Instrument

The instrument consist of the following :

Inner chamber of seamless steel pipe of at least 6 mm thickness

SS lid and provision for placing the rubber test pieces,

Pressure Control by Digital Pressure Controller

Jacket Heaters outside the Inner Chamber

PID Digital Temperature Indicating Controller , least count 0.1oC

Pressure Gauge Digital (least count 0.1 kg/cm2, )

Inlet, outlet for Air / Oxygen

Safety valve (preset / sealed at 25 kg/cm2)

Manifold with pressure switch, solenoid valve for compensating drop in pressure of gas from cylinders

Power cord, extra seal, rubber pipe to connect with cylinder

The sample is kept inside the pressure chamber under high temperature and pressure for the desired time period. After the

time period is over, the sample is tested visually for any creaks or deformations and also physical test are preformed like tensile

and elongation to determine the change as a result of ageing.

Safety Feature

The Chamber is designed with three safety devices for over shoot of pressure.

a) The input is regulated by digital pressure control which switch off the solenoid value once the desired pressure is reached.

b) A separate pressure switch with solenoid value is provided in series with the first solenoid value. The value of this pressure switch is set slightly higher than the set value, and will cut off the pressure if the digital pressure control fails.

c) A release value is provided on the top, set at 25 kg/cm2 and will release the pressure if both the solenoid fails.