Flammability Tester

  •   Model
  • SSI 566 FTISO (Flammability Tester as per ISO)  
  • Chamber 500 x 500 x 500 (LBH in mm)
  •   Chamber Construction
  • Five sided chamber (no top), with Clear Glass window Door  
  • Burner Specially Designed Micro Burner to produce 38 mm vertical flame (Adjustable)
  •   Burner Control
  • Through Gas Flow and pressure regulator and Flame Regulator.  
  • Timers Three, for Flame Burning, Unaided Burning, Glow Time
  •   Delivery

The ISO test serves as a preliminary indication of Textile / plastics material acceptability for use as part of a device or appliance with respect to its flammability.The test is conducted in a Five sided chamber without the roof top.

View Complete Details

Ladder Flammability Tester

  • Model SSI 514 FTLT (Flammability Test Apparatus , Ladder Type)
  • Burner Ribbon Type Burner, 300 mm Length
  • Burner Control Using Manometer controlled Gas and Air Flow to the Burner
  • Temperature Indicator Using 1m long ‘K’ Type Thermocouple
  • Sample Holder Ladder Fixed on a stand
  • Delivery Packing

model number: ssi 514 ftlt

standard number: ieee 383

this method covers a laboratory procedure for testing of bunch cables mounted vertically to determine their relative ability to resist flame prorogation. The test is conducted in open air environment only.

instrument principle

this method covers a laboratory procedure for testing of bunch cables mounted vertically to determine their relative ability to resist flame prorogation. The test should demonstrate that the bunched cable doesnt propagate fire even after its outer covering and insulation have been destroyed in the area of flame impingement.

standard

the instrument conforms to ieee 383.

instrument

the instrument consists of

ladder as sample stand

burner stand

ribbon type burner

control panel complete with manometers for lpg and air

temperature indicator

one meter long thermocouple

rubber pipe for lpg connection.

View Complete Details

Sample Die For Limiting Oxygen Index

  • Die Material MS hard chormed
  • Size of Sample 3 x 6 x 115 (LBH in mm)
  • No Of Sample 5 samples can be made at one time.
  • Delivery Ex Stock / 1-2 weeks
  • Packing Card Board Box

Model Number: SSI 515.1

Standard Number: ASTM D 2863IS 10810

Correct and accurate sample is necessary for result accuracy and repeatability. The Sample Die is designed to produce equal sized samples for testing Limiting oxygen Index Test Apparatus.

The Die is specifically designed to make samples for Limiting Oxygen Index Test Apparatus. The Die is manufactured in three pieces. The upper and lower plates are support plates. The Middle plate has cut out for the samples as per the standard requirement.

The Die with sample is kept in Hydraulic press for formation of smooth and accurate samples to be tested in for Limiting Oxygen Index.

View Complete Details

Flammability Test

  • Test Appalicable UL (HB/V0, V1, V2/5VA, 5VB)
  • Chamber Size 1 m x 1m x 1m (LBH)
  • Chamber Construction Double Walled, Inner Chamber made of Stainless Steel, Outer MS / GI
  • Burner Bunsen Burner, with adjustable flame length
  • Burner Position Adjustable form 0 to 90 deg (useful for both Vertical and Horizontal Burning)
  • Burner Movement Automated using PLC logic
  • Sample Holder Provided for both Vertical and Horizontal Test
  • Control All Funtions including Burner Movement, timers etc are controlled by PLC
  • Results PLC accumulate all the results and give the compliance of the sample
  • Display Using a touch screen HMI
  • Delivery 6 to 8 Weeks
  • Packing One Wooden Box

The UL test serves as a preliminary indicationfor Plasticscomponents acceptability for use as part of a device or appliance with respect to its flammability.The instrument is designed for both Vertical and Horizontal burning.

View Complete Details

High Current Tester

  • Current Capacity 0 to 160 Amps
  • Current Display Using Digital Ammeter
  • Voltage Diaplay Using Digital Voltmeter
  • Temperature Display Using Digital Temperature Indicator
  • Sensor Specially Designed Insulated PT 100 Sensor
  • Delivery Period Packing

Model Number: SSI 595

The instrument is designed to test the current capacity of any wire by passing very high current through it.

A wire is attached to the instrument and current is passed through it. The current is then gradually increased. The current at which the wire starts to burn is then noted.

The instrument consists of


Transformer capable to producing up to 200 Amps of current.
Varicto gradually increase the current.
Two Ampere Meter to measure the current at the start and end of sample wire.
Voltage Meter to measure voltage applied
Three Temperature indicators with thermocouples to measure the temperature of sample wire
Heavy duty Bakelite wire holders
On Off Switch and indicator
Data logger for recoding Current

The instrument is supplied with NABL Lab calibration for Ampere Meter.

View Complete Details

Halogen Acid Gas Emission Test Apparatus

  • Model SSI 518 HAGD (Halogen Acid Gas Emission Tester with Digital Flow Indicator)
  • Furance Tubular Furnace 50 mm Dia
  • Temperature Range Ambient to 1000oC, LC 1oC
  • Temperature Control Using PID Digital Temperature Controller with RAMP facility
  • Combustion Tube / Boat Made of Quartz, capable of withstanding temperatures up to 1200oC
  • Air Flow Controlled Air Flow using needle valve
  • Air Flow indicator Digital using air flow sensor, LC 0.01 LPM
  • Glass Ware Air Drying Bottles, Air Collection Bottles with bottle stand and magnetic Stirrer
  • Delivery 4 to 6 weeks from Order
  • Packing In three wooden boxes

model number: ssi 518 hag

standard number: iec 754 pt 1 & 2is 10810 pt 59

compounds based on halogenated polymers and compounds containing halogenated additives emits harmful halogen acid gas while burning. These gases are corrosive and can prove harmful to property and humans in case of fire.

instrument principle

compounds based on halogenated polymers and compounds containing halogenated additives emits harmful halogen acid gas while burning. These gases are corrosive and can prove harmful to property and humans in case of fire. Is 18010 (pt. 59) & iec 754-1-94 test determine the amount of halogen gas other than hydrofluoric acid evolved during the combustion of cables and other similar compounds.

standard

the instrument is manufactured as per the is specification and confirm to test app., method 754 2 fig 4.

instrument

the instrument comprising of

tubular furnace for temp. Up to1000oc +- 10oc.
pid digital temp. Indicating controller.
manometer with built-in air source.
quartz tube and quartz boat for keeping samples one each.
gas washing bottles 2 nos.
magnetic stirrer.
ph indicator ( for zero halogen) (optional)
conductivity indicator (for zero halogen) (optional)

View Complete Details

Oil Fume Density Tester

  • Model : SSI 516 OF (Oil Fume Test Apparatus)
  •   Smoke Chamber
  • :  100mm (Dia) x 200mm(Height)  
  • Saturation Chamber :  220mm (Dia) x 50mm (Height)
  •   Heating Plate
  • :  50 mm Dia  
  • Temperature :  Ambient to 300oC, LC 0.1oC
  •   Light Source
  • :  6 V DC Bulb  
  • Power Source :  Stabilized DC power source to product 5-7 V DC, adjustable
  •   Photo Receeptor
  • :  Highly Sensitive Photo metric Cell to determine even small chane in light intensity  
  •    
  •   Delivery
  • : 6 to 8 Weeks Packing 

Model Number: SSI 516 OF

Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the heating / burning (combustion) or decomposition of Oil and oil based material etc. under controlled conditions.

Instrument Principle

Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the heating / burning (combustion) or decomposition of Oil and oil based material etc. under controlled conditions.

The sample is heated under controlled temperature , through a specified designed heating system. A light source and a photo receptor is placed on either side of the chamber, and the percentage of light Transmitted / absorbed is displayed through a linear amplifier digital electronic photometer with 0 to 100% scale. The apparatus comes complete with timer with 1.5-second pulse at every 15 sec with hold facility, temperature controller for heating block and Roto Meter to control the air flow.

Instrument

The instrument comprising of

Heating Block

Saturation Chamber (including sample holding area)

Condensation / Smoke Chamber

Electronic Photometric System

Timer

Specimen Holder

Digital Temperature Controllers

Rotometers

View Complete Details

DC High Voltage (3 Core Cable)

  • DC Voltage : Up to 2 KV DC
  • Stations :  3 independent Stations
  • Voltage Control : Using Dimmer
  • Voltage Display : Using Analog Volt Meter
  • Cut Off : Using Tripping System on any short circuit
  •    
  • Delivery Time : 3 to 4 Weeks Packing : One Wooden Box

Model Number: SSI 569 TC

Standard Number: IS 1554IS 649

The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service.

Description

The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. It is necessary that a evaluation of the condition on the insulation be made by imposing a higher voltage stress for a short duration.

The DC High Voltage tester provides ideal condition to test any cable for its capability to withstand high DC voltage

The Instrument consist of (for each station)

Dimmer to increase / decrease the DC HV

HT DC output points

2 KV Voltmeter. (other voltages available on request)

Tripping Circuit

Cable connectors

Water Bath (to be purchased separately)

View Complete Details

Color Fastness To Day Light Exposure

  • Constrution :  Aluminum / Mild Steel Body with wooden / aycralic battens
  • Top :  Glass window top for exposure to Sun Light
  • Grey Standard :  Standard Color Grey standards as available from BIS
  •    
  • Delivery : 4 to 5 Weeks Packing : One Wooden Box

Model Number: SSI 527

Standard Number: IS 10810 Pt 18

The Test is designde to test the evpouration or fading of color when exposed to direct sunlight.

The Test is designde to test the evpouration or fading of color when exposed to direct sunlight. The sample is exposed to direct sunlight and is kept for a certian period of time. After the completion of the test, the color of the sample is compared with standard Grey Scale to determin the fading of the color.

View Complete Details

Smoke Density Tester

  •    
  • Chamber Size 300 mm x 300 mm x 790 mm
  • Chamber Construction Single Walled made of 14 gauge Aluminum Sheet, powder coated on both sides
  • Burner Specially Designed capable to work on 40 psi gas pressure
  • Sample Stand Designed to hold 25 x 25 x 4 mm Sample securely throughout the test
  • Light Source 6 V DC Bulb
  • Power Source Stabilized DC power source to produce 5-7 V DC, adjustable
  • Photo Receptor Highly Sensitive Photo metric Cell to determine even small change in light intensity
  • Display Using 7″ HMI to display various parameters of the instrument.
  • Control PLC control the various parameters of the instrument
  • Software Specially designed software to control, monitor and display the test parameters.
  • Power Requirement Single Phase, 220 V AC, 50 Hz, 0.5 KW (available in 110 V, 60 Hz also)
  • Delivery 4 to 6 weeks
  • Packing One Wooden Box

Model Number: SSI 516 SDASH

Standard Number: ASTM 2843, IS 13660 (Part 6/Sec9)

Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the burning (combustion) or decomposition of Plastic, Cables etc. under controlled conditions.


View Complete Details

Smoke Density Tester

Smoke Density Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the burning (combustion) or decomposition of Plastic, Cables etc. under controlled conditions.Smoke Density Test Apparatus is used for measuring & observing the relative amount (Density) of smoke produced by the burning (combustion) or decomposition of Plastic, Cables etc. under controlled conditions.
View Complete Details

Dc High Voltage Tester

  • DC Voltage Up to 2 KV DC
  • Voltage Control Using Dimmer
  • Voltage Display Using Analog Volt Meter
  • Cut Off Using Tripping System on any short circuit
  • Delivery Time Packing

Model Number: SSI 569

Standard Number: IS 649IS 1554

The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service.

The insulation material in a cable is used to isolate the conductor from one another and from ground, as well as provide the necessary mechanical strength. The fundamental requirement of the insulation in an electric cable is that it withstand the voltage imposed on it in the service. It is necessary that a evaluation of the condition on the insulation be made by imposing a higher voltage stress for a short duration.

The DC High Voltage tester provides ideal condition to test any cable for its capability to withstand high DC voltage

The Instrument consist of

Dimmer to increase / decrease the DC HV

HT DC output points

2 KV Voltmeter. (other voltages available on request)

Tripping Circuit

Cable connectors

Water Bath (to be purchased separately)

View Complete Details