Our Products
Specifications
Inner Chamber Sizes in mm / Inches W x D x H | No. Of Shelves | Capacity Cu.Ft. (Approx.) | Capacity (Approx.) |
---|---|---|---|
455 x 410 x 610 (18"x16"x24") | 2 Shelves | 4 Cu. Ft. | 112 Liters |
505 x 415 x 830 (20"x16"x33") | 2 Shelves | 6 Cu. Ft. | 171 Liters |
565 x 565 x 865 (23"x23"x34") | 3 Shelves | 10 Cu. Ft. | 280 Liters |
650 x 580 x 900 (26"x23"x35") | 3 Shelves | 12 Cu. Ft. | 336 Liters |
750 x 650 x 900 (29"x26"x35") | 4 Shelves | 15 Cu. Ft. | 425 Liters |
Technical Specifications
Range | 8%-40% |
---|---|
Measuring Principle | Electrical Resistance Measurement |
Measuring Facility | Direct Digital Display of moisture percent for seven different types of food grains (Viz : Aman paddy, Boro paddy, Parboiled rice, White/Atap rice, Hard wheat, Soft wheat & Maize) with electronic selector switch/switches. |
Measuring Range | Aman paddy : 9-20% Boro paddy : 9-20% Hard wheat : 9-20% Soft wheat : 9-20% Parboiled rice : 9-20% White/Atap rice : 9-20% Maize : 9-20% |
Permissible Error | ± 0.50 (plus minus zero point five) with reference to oven result obtained at 135 ± 20 C for 1 (one) hour. |
Function | Automatic temperature correction with averaging capability. |
Accessories | Coarse hand grinder for maize. Tough plastic husker, sample pans (Five nos), spoon (Two nos), with tweezers and brush, where applicable. |
Suitability in weather condition | The moisture meter must function accurately throughout the year at varying tropical weather conditions of Bangladesh. |
Type | Field type with hard protective best quality casing. |
Weight | Maximum 2 (Two) kg net with protective casing. |
Carrying facility | Carrying case with handle. |
Power Source | 1.5 Dry-Cell batteries ("AA" R6 size) and / or 9V Dry cell battery (6 F22 size). |
Technical Specifications
Principle | Digital Polarimeter based on Optical Null Principle |
---|---|
Modulator | Faraday magneto-optical modulator |
Minimum Sample Transmittance | 1% |
Multifunctional LED Display | Large & Bight |
Range of measurement Angular Scale | +45o to -45o |
Minimum value in (Angular Scale) | 0.001o |
Range of measurement (Sugar Scale) | +120o to -120o |
Minimum value in Sugar Scale | 0.01o |
Repeatability : Sample Transmittance | >1% |
Minimum sample transmittance | 1% |
USB interface | RS-232 Port |
Sample tube | 100mm, 200mm |
Measuring | > Specific rotation > Optical rotation > International Sugar Scale > Concentration |
Power supply | 220V ±22V, 50Hz ±1Hz |
Dimensions | 718mmx342mmx220mm |
Net Weight | 32 Kg (approx.) |
Light Source | Incandescence lamp plus interference filter, wavelength 589.44nm |
We are engaged in manufacturing Polarimeter (Research 220 mm) that is complete with Sodium Lamp & Transformer. We serve latest Research Polarimeter that is equipped with imported optical components and to accept observation tube up to 220mm length sensitive and accurate glass scale is divided to read angular degrees and also carries sugar scale in ISS units. The angular sale from 0-360 degrees is sub-divided to 1 degree to enable direct reading to 0.5 degree and by estimation 0.2 degrees. The sugar sale from 30 degrees to 120 degrees ISS units enable direct reading to. 1 and by estimation, 05 sugar degrees complete with Polarimeter tube 200mm in a wooden cabinet.