Post Buy Requirement
Tempsens Instruments (I) Pvt. Ltd.
Udaipur, Rajasthan, India
gstGST : 08AAACT5482C1ZF Verified Add Review

Our Product / Services

  1. Industrial Ovens & Furnaces 17 Products available
  2. Wires 3 Products available
  3. Insulated Cable 3 Products available
  4. Thermocouple 6 Products available
  5. Industrial Thermometer 3 Products available
  6. Security, Metal & Leak Detectors 3 Products available
  7. Measuring Instruments & Equipment 8 Products available
  8. Industrial Heaters 10 Products available
  9. Calibration Services 3 Services available
  10. Others 34 Products / Services available

Measuring Instruments & Equipment #5133364

Special Thermowells

  • Min. Order (MOQ) 50 Piece(s)
  • Brand Name Tempsens
  • Material SS, Inconel, Monel
  • Application Industrial
  • Type: Drilled Barstock, Fabricated Construction: Tapered, Straight, Helical
  • Process Connection: Screwed, Flanged Certification: IBR certification on request

Owing to our exceptional automated warehouse, the human interference has decreased that help us to make on-time deliveries as well. With substantial storage space, the products are kept with utmost safety to circumvent loss during loading and unloading. We have become a preferred choice of the patrons owing to our timeliness and client centric approach.

Details :

  • Metal Thermowells with Tungsten carbide/Ceramic/ PTFE/PVDF/PFA coatings
  • Solid sintered tungsten carbide
  • Silicon carbide(Recrystallised & Nitride Bonded)
  • Platinum thimble
  • Tantalum, Titanium, Nickle cladding
  • Tantalum Tungsten (Ta10W) Alloy
  • Graphite
  • Silicon Nitride
  • Other Materials in various sizes available on request

Additional Information:

Payment Terms : T/T

Packaging Details : Wooden Case

Delivery Time : 4-6 Weeks

View Complete Details

Non Contact Pyrometer (AST A250 & 450 PL-TL)

A250 PL/TL and A450 PL/TL are specially designed IR Pyrometers of A Series family for non contact temperature measurement in demanding industrial environments. The Pyrometers are highly accurate and compact by nature with stainless steel housing to provide high operational safety for harsh industrial environments. The Pyrometers are designed for high temperature applications between 210oC 3000oC.

Details :

  • The parameters like Emissivity, Analog Output, Sub Range, Response Time and Peak Picker etc can be preset ex-works or adjustable via Software.
  • The Pyrometer provided with bluetooth V2.0 for communication between pyrometer & Android mobile, RS-232 & 485 for communication between pyrometer & PC software Infrasoft.


Features :

  • Wide temperature ranges from 210oC to 3000°C.
  • Spectral Range 1.0 μm.1.6 μm
  • Fast response time within milliseconds
  • Analog output options available like 0.20mA, 4.20mA and 0.10V
  • Laser or Through the Lens view finder sighting options
  • Bluetooth V2.0 and RS-232/RS-485 Serial interface
  • User friendly PC software for communication
  • Small Spot Sizes
  • Accessories for mounting and cooling options


Standard Scope of Supply :

  • Pyrometer with Laser pilot light(PL)/Through the lens(TL) sighting(user can select while ordering)
  • Analog output 4.20mA, 0.20mA, 0.10V
  • Bluetooth V2.0
  • Digital Interface RS-232 / RS-485(user selectable)
  • 5 mtr long connection cable with connector
  • 1.5 mtr. Communication Cable
  • Calibration certificate, Software & Operation manual


Optional :

  • Mechanical & Electrical Accessories
  • Extra Cable Lengths
  • Single Analog Input 4.20mA for emissivity adjustment or background ambient compensation (to be specified while ordering)


Applications :

  • Induction Heating Sintering
  • Casting Melting
  • Annealing Rolling mills
  • Welding Hardening
  • Forging


Product Feature : Digital pyrometer with analog output & digital interface, USB output & laser targeting or view finder

Temperature Range :

  • A250 PL/TL
  • 210oC - 1350oC
  • 250oC - 1800oC
  • 300oC - 2500oC
  • 350oC - 3000oC
  • A450 PL/TL
  • Also available in AST A450 PL/TL Bluetooth
  • 600oC - 2500oC
  • 750oC - 2500oC

Downlaod


Download Detail File : Click Here

Technical Specification

Model A250 PL/TL A450 PL/TL
Temperature Range
(Analog sub-range
adjustable)
210oC….1350oC
250oC….1800oC
300oC….2500oC
350oC….3000oC
600oC….2500oC
Spectral Range 1.6 μm 1.0 μm
Photodetector Type InGaAs Si
Distance to Spot Size
Ratio
50:1 (210oC….1350oC)
100:1 (250oC….1800oC)
200:1 (300oC….2500oC)
200:1 (350oC….3000oC)
200:1 (600oC….2500oC)
Emissivity (ε) 0.1….1.0 adjustable
Response Time 2 msec adjustable upto 10 sec
Accuracy ± 0.3% of the measured value + 1oC
Repeatability 0.1% of reading in oC + 1oC
Sighting Options Laser Pilot Light (PL) / Through The Lens (TL)
Analog Output 0-20mA, 4-20mA, 0-10V (User selectable)
Digital Output Bluetooth V2.0
RS-232/RS-485 (User selectable)
*At a time only one digital output possible
Operating Temp. Range 0oC…….70oC
0oC…..200oC (With water cooling jacket)
Storage Temp. Range -20oC…70oC
Adjustable Parameters and
Features via Software
Emissivity, Response Time, Clear Time(Peak Picker),
Analog Output, Analog Scale (Sub Range), Unit Of
Temperature(°C/°F), Communication mode (Comm.
mode), Record feature etc
Power Supply ±12V to 28V DC/AC
Power Consumption Max 2.5 watt
Laser Power <1 m watt
Protection Class IP65
Housing Stainless Steel
Isolation Power supply, Digital output and Analog output are
galvanically islolated against each other
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g Dia= Ø 49.5 mm; Length=118mm

















Spot Sizes (mm)

Manufactured working
distances WD (mm)
A250 210oC - 1350°C
(50:1)
A250 250oC - 1800oC
(100:1)
A250
300oC - 2500oC
350oC - 3000oC(200:1)
A450
600oC - 2500oC
(200:1)
350 70 3.5 1.75 1.75
500 10 50 2.5 2.5
700 14 7 3.5 3.5
800 16 8 4 4
1000 20 10 5 5
1500 30 15 7.5 7.5
2000 40 20 10 10
2500 50 25 12.5 12.5
3000 60 30 15 15
5000 100 50 25 25
Aperture(A) 11 11 11 (300 - 2500oC)
4 (350 - 3000oC)
12(600 - 2500oC)








View Complete Details

Non Contact Pyrometer (AST EL50)

EL50 is an economic digital IR Pyrometer from E series with extended sensing head in 4 wire technology for non-contact temperature measurement between 0oC to 800oC.The sensor head is unaffected by electromagnetic interferences. The pyrometers are specially designed in a such way that sensor head can withstand ambient temperature upto 120oC easily.

Details :

  • The pyrometer is equipped with a Inbuilt 4 digit LCD display which offers many signal processing features. The electronic box with integrated Keypad helps in setting parameters like Emissivity, Analog Sub range, Set point, Hysteresis (Hyst), Analog Output, Unit of temp(°C or F), Response Time, Peak Picker and Sensor address etc.
  • EL50 is provided with USB 2.0 output and PC software. The pyrometer can be powered through USB port. In this case no external power supply is required. 24 VDC is required for operation of Analog Output, RS-232 & RS-485 & Relay Output.Analog output is 4…20mA, 0…20mA, 0…10V, Thermocouple type “K” or “J” (userselectable) via keypad or software. RS-232/RS-485 Serial interface card is available as optional.


Product Feature : Digital pyrometer with extended Sensor head. Analog and digital output, USB 2.0 Output, Inbuilt LCD, Laser Targeting & keypad for parameterization


Temperature Range : 0oC - 800oC

Features :

  • 12V to 28V DC with reverse polarity protection
  • Sensor head withstands ambient temperature upto 120°C
  • Spectral range 8 μm.14 μm
  • Wide temperature ranges (0oC to 800oC)
  • Inbuilt LCD Display and Keypad for parameterisation
  • Fast response time within milliseconds
  • Analog output 4…20mA, 0…20mA, 0…10V, Thermocouple
  • type “K” or“J” (user selectable)
  • USB 2.0 Digital output
  • RS-232/RS-485 Serial interface card
  • Relay output
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with LCD Display
  • Keypad for parameterizing
  • Extended Sensor head with 3 mtr cable
  • Analog output like 4…20mA, 0…20mA, 0…10V, Thermocouple type “K” or“J” (user selectable)
  • USB2.0 Digital output, USB Cable
  • Relay Output
  • Calibration certificate, Software & Operation manual


Optional :

  • Mechanical and Electrical Accessories
  • RS-232 / RS-485 interface card
  • Extra Sensor Head Extension Cable Lengths


Applications :

  • Plastic, Textile
  • Rubber Fluids
  • Ceramic Oxide/Painted metal surface
  • Paper Wood and Glass Industries

Downlaod


Download Detail File : Click Here

Technical Specification

Model EL50
Temperature Range (Analog
sub-range adjustable)
0o - 800oC
Spectral Range 8…14 μm
Photodetector Type Thermopile
Distance to Spot Size Ratio 2:1
15:1 (To be specified while ordering)
Emissivity (ε) 0.1….1.2 adjustable
Response Time 20 msec adjustable upto 10 sec
Accuracy ± 1% of the measured value or 3oC whichever value
is greater (The sensor head must be at constant
ambient temperature for a minimum of 15 minutes)
Repeatability 0.3% of reading in oC + 1oC
Analog Output 0-20mA, 4-20mA, 0-10V, Thermocouple Type “K” or
“J” (User selectable)
Digital Output USB 2.0
RS-232/RS-485 interface card (Optional)
*At a time only one digital output possible
Operating Temp. Range Electronic Box upto 70oC
Sensor head upto 120oC
Storage Temp. Range -20oC…70oC
Relay Output Relay Output with hysteresis 60V DC/42V AC
RMS,0.4A
Adjustable Parameters and
Features via Software
Emissivity, Response Time, Clear Time (Peak Picker),
Analog Output, Sub Range, Unit Of Temperature (°C/°F), Communication mode(Comm.mode), Record
feature etc.
Adjustable Parameters and
Features via Keypad
Emissivity, Setpoint, Hysteresis (Hyst), Analog Sub
Range, Analog Output, Unit of temperature, Sensor
address, Response Time, Clear Time (Peak Picker) etc.
Power Supply 12V to 28V DC with reverse polarity protection
Power Consumption Max 2.5 watt
Protection Class IP65
Housing Sensor head-Stainless Steel;
Electronic Box:Zinc
Isolation Power supply, *Digital output and Analog output are
galvanically islolated against each other
* Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g 112.5mm x 82.5mm x 33mm (L x W x H)


















View Complete Details

Non Contact Pyrometer (AST EL50H)

EL50-H is a digital Pyrometer in economic range with extended sensor head in 4 wire technology, for non-contact temperature measurement between 0oC to 800oC.The sensor head is unaffected by electromagnetic interferences. The pyrometer sensor head is specially designed to withstand ambient temperature upto 180oC without cooling.

Details :

  • The pyrometer is equipped with a Inbuilt 4 digit LCD display which offers many signal processing features. The electronic box with integrated Keypad helps in  setting parameters like Emissivity, Analog Sub range, Set point, Hysteresis (Hyst), Analog Output, Unit of temp(°C or F), Response Time, Peak Picker and Sensor address etc. Analog outputs options available are 4…20mA, 0…20mA, 0…10V, Thermocouple type “K” or “J” (userselectable) via keypad or software. RS- 232/RS-485 serial interface card is available as optional.
  • EL50-H is provided with USB 2.0 output and PC software. The pyrometer can be powered through USB port. In this case no external power supply is required. 24 V DC is required for operation of Analog Output, RS - 232 & RS - 485 & Relay Output.


Features :

  • Power supply (12V DC to 28 V DC) with reverse polarity protection
  • Sensor head can withstand ambient temperature upto 180°C
  • Spectral range 8 μm.14 μm
  • Wide temperature ranges (0oC to 800oC)
  • Inbuilt LCD Display and Keypad for parameterisation
  • Fast response time within milliseconds
  • Analog output like 4…20mA, 0…20mA, 0…10V, Thermocouple type “K” or“J” (user selectable)
  • USB2.0 Digital output and RS-232/RS-485 Serial interface card
  • Relay output
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with LCD Display
  • Keypad for parameterizing,
  • Extended sensor head with 3m cable
  • USB 2.0 Digital output, USB Cable
  • Relay Output
  • Analog output 4…20mA, 0…20mA, 0…10V, Thermocouple Type “K” or “J” (user selectable)
  • Calibration certificate, Software & operation manual


Optional :

  • Mechanical and Electrical Accessories
  • RS-232 & RS-485 serial interface card
  • Extra Cable Lengths


Applications :

  • Plastic, Rubber & Ceramic Fluids
  • Paper Oxide/Painted metal surface,
  • Textile Wood and Glass Industries


Product Feature :

  • Digital pyrometer with extended Sensor head. Analog and digital output, USB 2.0 Output, Inbuilt LCD, Laser Targeting & keypad for parameterization FOR Hot Environment UPTO 180oC


Temperature Range : 0oC - 800oC

Downlaod


Download Detail File : Click Here

Technical Specification

Model EL50-H
Temperature Range(Analog
sub-range adjustable)
0oC….800oC
Spectral Range 8…14 μm
Photodetector Type Thermopile
Distance to Spot Size Ratio 2:1
15:1 (To be specified while ordering)
Emissivity (ε) 0.1….1.2 adjustable
Response Time 60 msec adjustable upto 10 sec
Accuracy ±1.5% of the measured value or 3oC whichever is
greater (The sensor head must be at constant
ambient temperature for a minimum of 15 minutes)
Repeatability 0.3% of reading in oC + 1oC
Analog Output 0-20mA, 4-20mA, 0-10V, Thermocouple Type “K” or “J”
(User selectable)
Digital Output USB 2.0
RS-232/RS-485 interface card (Optional)
*At a time only one digital output possible
Operating Temp. Range Electronic box upto 70oC
Sensor head upto 180oC
Storage Temp. Range -20oC…70oC
Relay Output Relay Output with hysteresis 60V DC/42V AC RMS, 0.4A
Adjustable Parameters and
Features via Software
Emissivity, Response Time, Clear Time (Peak Picker), Analog Output, Analog Scale (Sub Range), Unit Of Temperature (oC/oF), Communication mode(Comm.
mode), Record feature etc.
Adjustable Parameters and
Features via Keypad
Emissivity, Setpoint, Hysteresis (Hyst), Analog Sub Range, Analog Output, Unit of temperature, Sensor address, Response Time, Clear Time(Peak Picker) etc.
Power Supply 12V DC to 28 V DC with reverse polarity protection
Power Consumption Max 2.5 watt
Protection Class IP65
Housing Sensor head-Stainless Steel
Electronic Box - Zinc
Isolation Power supply, *Digital output and Analog output are
galvanically islolated against each other
* Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, non condensing conditions
Weight & Dimensions 600g 112.5mmx82.5mmx33mm(L x W x H)














View Complete Details

Non Contact Pyrometer (AST E250 PL & E450 PL)

E250 PL and E450 PL are highly economic digital IR pyrometers with extended sensor head and separate electronic box for non-contact temperature measurement of metals, ceramics and graphite etc in temperature ranges between 250oC and 1900oC

Details :

  • E250 PL and E450 PL IR Pyrometers are two piece measurement systems containing one extended sensor head and one electronic box .The electronic box comes with Inbuilt 4 digit LCD display which offers many signal processing features.The Keypad on the electronic box helps in setting parameters like Emissivity, Analog Sub range, Set point, Hysteresis (Hyst), Analog Output, Unit of temp(oC or F), Response Time, Peak Picker and Sensor address etc. The sensor head is un-effected by electromagnetic interferences.
  • E250 PL and E450 PL Infrared Pyrometers are provided with USB 2.0 output & PC Software for communication. The pyrometer can be powered through USB port, in this case no external power supply is required. 24V DC is required for operation of Analog output 4.20mA, 0.20mA, 0. 10V, Laser, RS-232/RS-485 and Relay output.


Product Feature :

  • Digital pyrometer with extended optical head.
  • Inbuilt LCD & Keypad for parameterization.


Temperature Range : E250 PL

  • 250oC.1000oC
  • 300°C.1300oC
  • 350oC.1800oC
  • E450 PL
  • 600oC1900oC


Features :

  • Wide temperature ranges from 250oC to 1900°C.
  • Spectral range from 1.0 μm.1.6 μm
  • Inbuilt LCD Display and Keypad for parameterisation
  • Fast response time within milliseconds
  • Laser Targeting light for precision targeting
  • Analog output options available like 0.20mA, 4.20mA and 0.10V
  • USB2.0 Digital output and RS-232/RS-485 Serial interface
  • Relay output
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with LCD Display
  • Keypad for parameterizing
  • Extended Sensor head with 3 mtr cable
  • Laser Targeting Light
  • Analog output 4.20mA, 0.20mA, 0. 10V
  • USB 2.0 Digital output, USB cable
  • Relay Output
  • Calibration certificate, Software & Operation manual


Optional :

  • Mechanical & Electrical Accessories
  • RS-232 / RS-485 Interface card
  • Extra Sensor Head Extension Cable Lengths


Applications :

  • Induction heating Forging
  • Casting Sintering
  • Annealing Melting
  • Welding Rolling

Downlaod


Download Detail File : Click Here

Technical Specification

Model E250 PL E450 PL
Temperature Range(Analog
sub-range adjustable)
250oC….1000oC
300oC….1300oC
350oC….1800oC
600oC…1900oC
Spectral Range 1.6 μm 1.0 μm
Photodetector Type InGaA Si
Distance to Spot Size Ratio 20 : 1
40 : 1
80 : 1
3.3340277778
Emissivity (ε) 0.1….1.0 adjustable
Response Time 2 msec adjustable upto 10 sec
Accuracy ±0.3% of the measured value +1o C
Repeatability 0.1% of reading in oC +1oC
Sighting Option Laser Pilot Light(PL)
Analog Output 0-20mA, 4-20mA, 0-10V(User Selectable)
Digital Output USB 2.0 output
RS - 232 / RS - 485 interface card (Optional)
*at a time only one digital output possible
Operating Temp. Range Electronic Box and Sensor Head upto 70oC
Storage Temp. Range -20oC….70oC
Relay Output Relay output with hysteresis 60V DC / 42V AC RMS,
0.4A
Adjustable Parameters and
Features via Software
Emissivity, Response Time, Clear Time(Peak Picker),
Analog Output, Analog Scale(sub range), Unit of
Temperature (oC/oF), Communication mode(Comm.
mode), Record Feature etc.
Adjustable Parameters and
Features via Keypad
Emissivity, Set Point, Hysteresis (Hyst), Analog Sub
Range, Analog Output, Unit of temperature, Sensor
address, Response Time, Clear Time (Peak Picker) etc.
Power Supply 24V DC
Power Consumption Max 2.5 watt
Laser Power <1 m watt
Protection Class IP65
Housing Sensor Head : Stainless Steel
Electronic Box : Zinc
Isolation
  • Power supply,  Digital output and Analog output are
  • galvanically isolated against each other
  • Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g 112.5mmx82.5mmx33mm (L x W x H)
















Spot Sizes (mm)

Manufactured Working
Distances WD (mm)
E250250oC-1000oC
(20:1)
E250 300oC-1300oC
(40:1)
E250 350oC-1800oC
(80:1)
E450600oC-1900oC (80:1)
90 4.5 2.3 1.2 1.2
300 15 7.5 3.8 3.8
600 3 15 7.5 7.5
Aperture(A) 5 5 5 5




View Complete Details

Non Contact Pyrometer (AST E450C PL)

E450C PL is a two color pyrometer from economic series.The Pyrometer model is a two piece measurement system containing one extended sensor head and one electronic box for non-contact temperature measurement of metals, ceramics and graphite etc. in a temperature range between 800oC to 2500oC.

Details :

  • This device measures the temperature of an object by calculating the ratio of the energies at two different wavelength bands. The ratio technique eliminates and reduces errors in temperature measurement caused by changes in Emissivity, Surface finish and energy absorbing materials such as Water vapour etc.The sensor head is unaffected by electromagnetic interferences.
  • The Pyrometer is equipped with a Inbuilt 4 digit LCD display which offers many signal processing features. The electronic box with integrated Keypad helps in setting parameters like Emissivity, Analog Sub range, Set point, Hysteresis (Hyst), Analog Output, Unit of temp(°C or F), Response Time, Peak Picker and Sensor address etc.


Product Feature :

  • Digital two color pyrometer with extended Sensor head.
  • Analog and digital output, USB 2.0 Output, Inbuilt LCD, Laser Targeting & keypad for parameterization


Temperature Range : 800oC - 2500oC

Features :

  • Wide temperature ranges from 800°C to 2500°C.
  • Spectral range from 0.7 μm.1.15 μm
  • Laser Pilot Light for precision targeting
  • Two Color model
  • Inbuilt LCD Display and Keypad for parameterisation
  • Fast response time within milliseconds
  • Analog output options available like 0.20mA, 4.20mA and 0.10V
  • USB 2.0 Digital output and RS-232/RS-485 Serial interface
  • Relay output
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with LCD Display
  • Keypad for parameterizing
  • Extended Sensor head with 3 mtr cable
  • Laser Targeting Light
  • Analog output 4.20mA, 0.20mA, 0. 10V
  • USB 2.0 Digital output, USB Cable
  • Relay Output
  • Calibration certificate, Software & Operation manual


Optional :

  • Mechanical and Electrical Accessories
  • RS-232/RS-485 interface card
  • Extra Cable Lengths


Applications :

  • Induction heating Forging
  • Casting Sintering
  • Annealing Melting
  • Welding Rolling

Specifications

Model E450C PL
Temperature Range (Analog
sub-range adjustable)
800oC….2500oC
Spectral Range 0.7…1.15 μm
Photodetector Type Si/Si
Distance to Spot Size Ratio 3.3340277778
Emissivity (ε) 0.1….1.0 adjustable (Single Color mode)
Emissivity Slope (ε1 / ε2) 0.75…1.25 slope adjustable (Two color mode)
Response Time 20 msec adjustable upto 10 sec
Accuracy ± 0.5% of the measured value + 1oC
Repeatability 0.1% of reading in oC + 1oC
Sighting Option Laser Pilot Light (PL)
Analog Output 0-20mA, 4-20mA, 0-10V (User selectable)
Digital Output USB 2.0
RS-232/RS-485 interface card (Optional)
*At a time only one digital output possible
Operating Temp. Range Electronic box and Sensor head upto 70oC
Storage Temp. Range -20oC….70oC
Relay Output Relay Output with hysteresis 60V DC/42V AC RMS,
0.4A
Adjustable Parameters and
Features via Software
  • Emissivity, Emissivity Slope, Response Time, Clear
  • Time (Peak Picker), Analog Output and Analog Scale
  • (Sub range), Sensor type (Switches b\w 2-color or
  • single color), Switch off level, Unit Of Temperature
  • (°C/°F), Communication mode(Comm.mode), Record
  • feature etc.
Adjustable Parameters and
Features via Keypad
  • Emissivity, Set point, Hysteresis (Hyst), Analog Sub
  • Range, Analog Output, Unit of temperature, Sensor
  • address, Sensor type (Switches b\w 2-color or single
  • color), Switch off level, Response Time, Clear Time
  • (Peak Picker) etc
Power Supply 24V DC
Power Consumption Max 2.5 watt
Laser Power <1 m watt
Protection Class IP65
Housing
  • Sensor Head - Stainless Steel
  • Electronic Box - Zinc
Isolation
  • Power supply, Digital output and Analog output are
  • galvanically isolated against each other
  • Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g 112.5mm x 82.5mm x 33mm (L x W x H)







Download Detail File : Click Here
View Complete Details

Non Contact Pyrometer (AST A450C)

A450C PL/TL is a highly accurate digital two colour IR pyrometer from A series family for non contact temperature measurement. The Pyrometer measures the temperature of an object by calculating the ratio of the energies at two different wavelength bands. The ratio technique eliminates and reduces errors in temperature measurement caused by changes in Emissivity, Surface finish and energy absorbing materials such as Water vapour etc.

Details : The two colour IR Pyrometer is used to measure the temperature in variety of applications in Steel(Induction heating, Forging, Annealing, Welding, Sintering and Rolling mills), Cement(Kiln burning zone ), Glass(Gob temperature measurement) and Crystal growing.

Features :

  • Wide temperature ranges from 600oC to 2500oC.
  • Spectral range 0.7 μm.1.15 μm
  • Fast response time within milliseconds
  • Two Color model
  • Laser targeting / Through the lens view finder sighting options
  • Analog output options available like 0.20mA, 4.20mA and 0.10V
  • USB2.0 Digital output and RS-232/RS-485 Serial interface
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with Laser pilot light(PL)/Through the lens(TL) sighting(user can select while ordering)
  • Analog output 4.20mA, 0.20mA, 0.10V
  • USB 2.0 Digital output, USB Cable
  • Digital Interface RS-232 / RS-485(user selectable)
  • 5 mtr long connection cable with connector
  • 1.5 mtr. Communication Cable
  • Calibration certificate, Software & Operation manual


Optional :

  • Mechanical & Electrical Accessories
  • Extra Cable Lengths


Applications :

  • Induction Heating Melting
  • Annealing Rolling Mills
  • Welding Rolling Kilns
  • Forging Crystal growing
  • Sintering


Product Feature : Digital two color pyrometer with analog output & digital interface, USB output& laser targeting or view finder

Temperature Range :

  • 600oC - 1600oC
  • 800oC - 2500oC

Downlaod


Download Detail File : Click Here

Technical Specification

Model A450C PL/TL
Temperature Range (Analog sub-range
adjustable)
600oC….1600oC
800oC….2500oC
Spectral Range 0.7….1.15 μm
Photodetector Type Si/Si
Distance to Spot Size Ratio 100:1 (600oC….1600oC)
200:1 (800oC…..2500oC)
Emissivity (ε) 0.1….1.0 adjustable (Single color mode)
Emissivity Slope (ε1 / ε2) 0.75…1.25 slope adjustable (Two color mode)
Response Time 20 msec adjustable upto 10 sec
Accuracy ± 0.5% of the measured value + 1oC
Repeatability 0.1% of reading in oC + 1oC
Sighting Options Laser Pilot Light(PL) / Through The Lens (TL)
Analog Output 0-20mA, 4-20mA, 0-10V (User selectable)
Digital Output USB 2.0
RS-232/RS-485 (User selectable)
*At a time only one digital output possible
Operating Temp. Range 0oC…….70oC
0oC…..200oC (With water cooling jacket)
Storage Temp. Range -20oC…70oC
Adjustable Parameters and
Features via Software
  • Emissivity, Emissivity Slope, Response Time, Clear
  • Time( Peak Picker), Analog Output, Analog Scale(Subrange),Sensor type (Switches b\w 2-color or single
  • color), Switch off level, Unit Of Temperature(oC/oF),
  • Communication mode(Comm.mode), Record feature etc
Power Supply 24V DC
Power Consumption Max 2.5 watt
Laser Power <1 m watt
Protection Class IP65
Housing Stainless Steel
Isolation
  • Power supply,Digital output and Analog output are
  • galvanically islolated against each other
  • Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g Dia= Ø 49.5 mm; Length=118mm







Spot Sizes (mm)

Manufactured working distances WD
(mm)
600o - 1600oC
(FOV) 100:1
800o - 2500oC
(FOV) 200:1
350 3.5 1.75
500 5 2.5
700 7 3.5
1000 10 5
1500 15 7.5
2000 20 10
2500 25 12.5
3000 30 15
5000 50 25
Infinite (∞) 8 (min.) 5 (min.)
Aperture (A) 7 4



View Complete Details

Non Contact Pyrometer (AST A150)

A150 is a specially designed highly accurate digital IR Pyrometer operating at the near end of the infrared spectrum and is therefore an excellent choice for measurement of ferrous and non ferrous metals above 75oC because the emissivity of un-oxidized metalsurfaces is higher at shorter wavelengths. The parameters like Emissivity, Analog output, Sub-range, Response time and Peak picker can be preset ex-works or adjusted via software. This enables the instrument to be adapted for various measuring tasks.

Details :

  • A150 Infrared Pyrometer is provided with USB 2.0 connector with cable.The infrared Pyrometer can be powered through USB port. In this case no external power supply is required (+24V DC is required for operation of Analog output, Laser, RS- 232/RS-485 output.
  • The pyrometer has solid body in stainless steel housing which provides high operation safety even in rough industrial environment. Variety of working Distances with fixed focus available for different applications.


Features :

  • Wide temperature ranges from 75oC to 700oC.
  • Spectral range 2 μm.2.6 μm
  • Laser targeting
  • Fast response time within milliseconds
  • Analog output options available like 0.20mA, 4.20mA, 0.10V
  • Digital USB2.0 output and RS-232/RS-485 Serial interface
  • User friendly PC software for communication


Standard Scope of Supply :

  • Pyrometer with Laser pilot light(PL)
  • Analog output 4.20mA, 0.20mA, 0.10V
  • Digital USB 2.0 output with USB Cable
  • Digital Interface RS-232 & RS-485(user selectable),
  • 5 mtr long connection cable with connector,
  • 1.5 mtr. Communication Cable,
  • Calibration certificate, Software & Operation manual.


Optional :

  • Mechanical and Electrical Accessories
  • Extra Cable Lengths


Applications :

  • Induction Heating Sintering
  • Casting Melting
  • Annealing Rolling mills
  • Welding Hardening
  • Forging


Product Feature : Digital pyrometer with analog output & digital interface, USB output & laser targeting for metallic surface at low temperature

Temperature Range : 150oC - 700oC

Downlaod


Download Detail File : Click Here

Technical Specification

Model A150
Temperature Range (Analog sub-range adjustable) 75oC….700oC
Spectral Range 2 μm to 2.6 μm
Photodetector Type Extended InGaAs
Distance to Spot Size Ratio 2.0840277778
Emissivity (ε) 0.1….1.0 adjustable
Response Time 2 msec adjustable upto 10 sec
Accuracy Upto 400oC: 3oC >400oC: 0.5% of measured value in oC + 1oC
Repeatability 0.1% of reading in oC + 1oC
Sighting Options Laser Pilot Light (PL)
Analog Output 0-20mA, 4-20mA, 0-10V (User selectable)
Digital Output USB 2.0
RS-232/RS-485 (User selectable)
*At a time only one digital output possible
Operating Temp. Range 0oC…….70oC
0oC…..200oC (With water cooling jacket)
Storage Temp. Range -20oC…70oC
Adjustable Parameters & Features via Software Emissivity, Response Time, Clear Time(Peak Picker), Analog Output, Analog Scale (Sub Range) , Unit Of Temperature(oC/oF), Communication mode (Comm.mode), Record feature etc
Power Supply 24V DC ±1V, Ripple must be less than 50 mV
Power Consumption Max 2.5 watt
Laser Power <1 m watt
Protection Class IP65
Housing Stainless Steel
Isolation
  • Power supply,Digital output and Analog output are galvanically islolated against each other
  • Not applicable for USB 2.0 digital output
Operating Humidity 10-95%, Non-Condensing Conditions
Weight & Dimensions 600g Dia= Ø 49.5 mm; Length=118mm



Spot Sizes

Manufactured working
distance WD (mm)
350 500 700 800 1000 1500 2000 2500 3000 500 Aperture(A)
Spot Size(50:1)(mm) 7 10 14 16 20 30 40 50 60 100 18

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us