6 seconds without sintered cap; 60 seconds with sintered cap : -20°C (4 mA) to 60°C (20 mA)
79 x 49 x 150 mm (3.1 x 1.9 x 5.9”) : 150 g (5.3 oz.)
±1% FS : 0 to 60°C (32 to 140°F)
HI8666 is supplied with built-in RH sensor, protective sintered cap for RH sensor, mounting brackets and instructions. : Power Supply: 10-30 Vdc
Output Signal: 4 to 20 mA
Panel Cutout: 73 x 42 mm (2.9 x 1.6")
Application : Clean Room& HVAC , building management systems, museums, libraries etc.
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative humidity and temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional ROTRONIC HW4 software enables...
Transmitter Accept input RTDs, Voltage , current Process â Temperature and Humidity Temperature Range : 0 to 50 Deg C Temperature Out put : 0 4-20mA ( 2 Wire) Humidity Range : 0 to 100 % RH Humidity Out put : 0 4-20mA ( 2 Wire) Calibration Zero and Span adjustment Accuracy...
Application : HVAC & Building Automation Systems, Food Stores, Health Inspection Agencies, Warehouse Mapping, Paper, Textile and Pharmaceuticals Industries.
Measures Humidity, Temperature and Calculates Dew Frost Point Temperature Compensated humidity signal Standard Scaling : 4â¦20mA = 0...100%rh -50...200 ºC Temperature Ready for direct 3 - wire RTD connection housing and can also be supplied in an industry standard IP65...
Typical Areas Of Application : Climatic Rooms/Chambers,HVAC Installations,Green Houses,Paper Industries,Incubators, Ovens,Textile Industries,Storage Area,Food Processing Industries,Fruit/Vegetable Storage
Purity : Fast, Stable And Accurate,IP 65 - Watertight Enclosure,Excellent Long Term Stability,Onsite Two Point Calibration,4 - 20 MA Analog Output,Current Loop Supply Of 12 - 30 VDC
Series : TRH-30x
Material : Thin Film Polymer Capacitor, Thin Film RTD
Application : Ventilating & Heating, Clean Room T Rh Monitoring, Air Conditioning (HVAC), Gas Sterilizers Systems, Green House Monitoring, Environmental Chamber, Duct Air Temp. Humidity Monitoring, Stability Sensor
The HygroFlex1 series is the latest development in inexpensive HVAC transmitters for relative humidity and temperature. The devices are equipped with the tried-and-tested Hygromer® IN-1 sensor and boast unbeatable value for money. The optional...
Measures Humidity, Temperature and Calculates Dew / Frost Point Temperature Compensated humidity signal Standard Scaling : 4…20mA = 0...100%rh / -50...200 ºC Temperature Ready for direct 3 - wire RTD connection housing and can also be supplied in...
Transmitter Accept input RTDs, Voltage , current Process – Temperature and Humidity Temperature Range : 0 to 50 Deg C Temperature Out put : 0 /4-20mA ( 2 Wire) Humidity Range : 0 to 100 % RH Humidity Out put : 0 /4-20mA ( 2 Wire) Calibration Zero...
Our combo 2-in-1 humidity and temperature transmitters are perfectly dependable for your industrial automation needsthat require these two parameters to be measuredsimultaneously. Thedesign of these transmitters ensuresexcellent reliability,...
Measures Humidity, Temperature and Calculates Dew Frost Point Temperature Compensated humidity signal Standard Scaling : 4â¦20mA = 0...100%rh -50...200 ºC Temperature Ready for direct 3 - wire RTD connection housing and can also be supplied in...