Power Transformers #2267763

Medium Voltage Indoor Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Casting Epoxy Resin
  • Highest Current For Equipment(kV) Up to 36Kv
  • Rated Insulation Level(kV) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • No of Phases 1-Phase or 3-Phase
  • Rated Primary Voltage(V) Up to 33kV
  • Rated Secondary Voltage(V) 110V/RT3, 110V/3, 110V(As Per Requirement)
  • Accuracy Class 0.1, 0.2, 0.5, 1, 3
  • Rated Burden(VA) Up to 500VA
  • Accuracy Class of Protection Core 3P and 6P
  • Number of Windings 1-2-3-4-5
  • Class of Insulation Class B, F & H
  • Voltage Factor 1.2 Continuous/1.5 for 30 sec, 1.9 for 8 hours
  • Type of Earthing One End Earthed Type(E-N) / UN Earthed Type(U-N)
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Low Voltage Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 1 Piece
  • Type Wound Primary/Ring/Rectangular
  • Finishing Tape Insulated/Epoxy Resin/cycloaliphatic
  • Class Of Insulation Class B, F & H
  • Highest Voltage for Equipment (kV) 1.1kV
  • Rated Insulation Level (kV) 1.1 / 4kV
  • Rated Frequency (Hz) 50-400Hz
  • Rated Primary Current (A) Up to 25000A
  • Rated Secondary Current(A) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Number of Cores 1-2-3-4-5
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Medium Voltage Outdoor Cycloaliphatic Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Number Of Cores 1-2-3-4-5
  • Application Outdoor
  • Type Wound Primary / Window Type
  • Casting Cycloaliphatic Epoxy Resin
  • Highest Current For Equipment(Kv) Up to 36kV
  • Rated Insulation Level(Kv) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • Rated Primary Current(A) Up to 10000A
  • Rated Secondary Current(C) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Short Time Thermal Current(STC) >Up to 40 kA at 0.5sec 1, sec or 3 sec
  • Class of Insulation Class B, F & H
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • Mr. Masidda Alligid (Kalpa Electrikal Pvt Ltd)
  • P. B. No. 4413, 149/25, III Main, Industrial Town, Bangalore, Karnataka - 560010
  • Share us via
  • Call 08069247353 Ext. 213
Manufacturer of Power Transformers from Bangalore, Karnataka by Kalpa Electrikal Pvt Ltd
Post Buy Requirement
Kalpa Electrikal Pvt Ltd
Bangalore, Karnataka, India
gstGST : 29AAACK7799P1ZD Verified Add Review

Power Transformers #2267763

Medium Voltage Indoor Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Casting Epoxy Resin
  • Highest Current For Equipment(kV) Up to 36Kv
  • Rated Insulation Level(kV) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • No of Phases 1-Phase or 3-Phase
  • Rated Primary Voltage(V) Up to 33kV
  • Rated Secondary Voltage(V) 110V/RT3, 110V/3, 110V(As Per Requirement)
  • Accuracy Class 0.1, 0.2, 0.5, 1, 3
  • Rated Burden(VA) Up to 500VA
  • Accuracy Class of Protection Core 3P and 6P
  • Number of Windings 1-2-3-4-5
  • Class of Insulation Class B, F & H
  • Voltage Factor 1.2 Continuous/1.5 for 30 sec, 1.9 for 8 hours
  • Type of Earthing One End Earthed Type(E-N) / UN Earthed Type(U-N)
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Low Voltage Indoor Resin Cast Current Transformer

  • Min. Order (MOQ) 1 Piece
  • Type Wound Primary/Ring/Rectangular
  • Finishing Tape Insulated/Epoxy Resin/cycloaliphatic
  • Class Of Insulation Class B, F & H
  • Highest Voltage for Equipment (kV) 1.1kV
  • Rated Insulation Level (kV) 1.1 / 4kV
  • Rated Frequency (Hz) 50-400Hz
  • Rated Primary Current (A) Up to 25000A
  • Rated Secondary Current(A) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Number of Cores 1-2-3-4-5
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details

Medium Voltage Outdoor Cycloaliphatic Resin Cast Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Number Of Cores 1-2-3-4-5
  • Application Outdoor
  • Type Wound Primary / Window Type
  • Casting Cycloaliphatic Epoxy Resin
  • Highest Current For Equipment(Kv) Up to 36kV
  • Rated Insulation Level(Kv) Up to 36/70/170kVp
  • Rated Frequency(Hz) 50-400Hz
  • Rated Primary Current(A) Up to 10000A
  • Rated Secondary Current(C) 5A or 1A
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Short Time Thermal Current(STC) >Up to 40 kA at 0.5sec 1, sec or 3 sec
  • Class of Insulation Class B, F & H
  • Applicable Standards IS, IEC, ANSI, BS, etc.