Cast Resin Type Dry Type Transformer

  • Min. Order (MOQ) 1 Piece
  • Frequency 50/60 Hz
  • Capacity UPTO 2.5 MVA
  • Class Of Insulation Class B/F/H with Temp Rise of 70/90/115 Deg C or as per customer requirement.
  • Tapping Range OCTC or OLTC As Per Customer Requirements
  • Winding Material Copper
  • Duty Type Outdoor / Indoor , Convertor Duty, Special Type
  • Voltage Class UPTO 33 kV
  • No of Phases 1 Phase or 3 Phase
  • Vector Group Dyn1 or Dyn5 or Dyn11 or any other connection as per customer requirement.
  • Tap Changer Off Circuit or On Load.
  • Applicable Standards IS 11171, IEC 60076
  • Painting Painting : Powder Coated with RAL 7032 Shade or As Per Customer Requrement
  • Degree of protection IP 23, 43 or As Per customer requirement.
  • Duty Type Outdoor/Indoor, Convertor Duty, Special Type

At Kalpa Electrikal Pvt Ltd, casting method of these transformers is obtained with the combined action of vacuum and temperature. The casting method makes it possible to assure void-free epoxy penetration of both the inner layer and between turn insulation. These Transformers are specifically needed in the distribution network for feeding basements or stilts of high-rise buildings, hotels, Malls, stadi-um, airports, chemical & refinery plants.

Assured Features

  • Windings are electrically balanced to minimize axial short circuit forces.
  • Coils are held rigidly in place between insulators clamped to the upper and lower core frames under highcompression.
  • Precise casting under vacuum ensuring low partial discharge.
  • Smooth surface finish and robust construction of MV & LVcastCoils.
  • Adequate ducts between coils, discs for maximum airowand reducedhotspotTemperature.
  • Step-lap designed CRGO laminations for lower losses and excitationcurrent.


Standard Fittings

  • H.V. Cable box.
  • L.V. Cable box with bus bar or bus duct
  • Off circuit tap links.
  • Undercarriage with four Bi-directional rollers.
  • Earthing terminals.
  • Rating and diagram plate.
  • Lifting lugs for complete Transformer
  • Tapping link operation door
  • Enclosure with louvre panels
  • Canopy
  • Base channel 2 Nos
  • The separate neutral bushing on LV side
  • Paint: Powder coated With RAL7032 Shade


Optional Fittings

  • RTD with A/T contact.
  • Marshaling box with control wiring.
  • On Load tap changer.
  • Forced Cooling arrangement.
  • Neutral Current Transformer.


Safety Features

  • Environment-Friendly
  • Fire Resistance
  • Non-Hygroscopic
View Complete Details

Vacuum Pressure Impregnated Dry Type Transformer

  • Min. Order (MOQ) 1 Piece
  • Capacity Up to 5MVA
  • Frequency 50/60Hz
  • Class Of Insulation Class B/F/H with Temp Rise of 70/90/115 Deg C or as per customer requirement.
  • Tapping Range OCTC or OLTC As Per Customer Requirements
  • Winding Material Copper
  • Duty Type Outdoor/Indoor, Ground Mounted AN/AF
  • Voltage Class UPTO 11 kV
  • No of Phases 1 Phase or 3 Phase
  • Vector Group Dyn1 or Dyn5 or Dyn11 or any specification.
  • Tap Changer Type Off Circuit or On Load.
  • Applicable Standards IS 11171, IEC 60076
  • Enclosure Painting Powder coated with RAL 7032 shade or as per customer requirement
  • Degree of Protection Ip 23, 43 or as per Customer Requirement.

We Kalpa Electrikal Pvt Ltd manufacture conventional open enclosure type vacuum pressure impregnated dry Transformers. These Transformers are specifically needed in the distribution network for feeding basements or stilts of high-rise buildings, hotels, Malls, stadium airports, chemical & refinery plants.

Assured Features

  • Windings are electrically balanced to minimize axial short circuit forces.
  • Coils are held rigidly in place between insulators clamped to the upper and lower core frames under high compression.
  • Precise casting under vacuum ensuring low partial discharge.
  • Smooth surface finish and robust construction of MV & LV cast Coils.
  • Adequate ducts between coils, discs for maximum air ow and reduced hot spot Temperature.
  • Step-lap designed CRGO laminations for lower losses and excitationcurrent.


Standard Fittings

  • H.V. Cable box.
  • L.V. Cable box with bus bar or bus duct
  • Off circuit tap links.
  • Undercarriage with four Bi-directional rollers.
  • Earthing terminals.
  • Rating and diagram plate.
  • Lifting lugs for complete Transformer
  • Tapping link operation door
  • Enclosure with louvre panels
  • Canopy
  • Base channel 2 Nos
  • The separate neutral bushing on LV side
  • Paint: Powder coated With RAL7032 Shade


Optional Fittings

  • RTD with A/T contact.
  • Marshaling box with control wiring.
  • On Load tap changer with RTCC Panel with AVR
  • Forced Cooling arrangement.
  • Neutral Current Transformer.
  • Space heaters for core & windings


Safety Features

  • Environment-Friendly
  • Fire Resistance
  • Non-Hygroscopic