My ExportersIndia

For Buyer

For Seller

For Help

Kalpa Electrikal Pvt Ltd
gstGST : 29AAACK7799P1ZD Write a Review

Voltage Transformers

We offer a complete product range of Low Voltage Indoor Tape Insulated Current Transformer, Low Voltage Indoor Moulded Case Current Transformer and Low Voltage Indoor Voltage Transformer

Low Voltage Indoor Tape Insulated Current Transformer

  • Min. Order (MOQ) 1 Piece
  • Number Of Flower Wound Primary/Ring/Rectangular
  • Finishing Tape Insulated
  • Accuracy Class 0.1, 0.2s, 0.2, 0.5s, 0.5, 1, 3, 5
  • Highest Voltage for Equipment (kV) 1.1kV
  • Rated Insulation Level (kV) 1.1/4kVp
  • Rated Frequency (Hz) 50-400Hz
  • Rated Primary Current (A) Up to 25000A
  • Rated Secondary Current(A) 5A or 1A
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden (VA) Up to 30VA (As Per Requirement)
  • Accuracy Class of Protection Core 5P to 15P
  • Accuracy Limited Factor(ALF) 5 to 30
  • Special Protection(PS/PX) VK=> .v(As Per Requirement)
  • Short Time Thermal Current(STC) Up to 40 kA at 0.5sec 1, sec or 3 sec
View Complete Details

Low Voltage Indoor Moulded Case Current Transformer

  • Min. Order (MOQ) 1 Piece
  • Number Of Flower Bar Primary/Ring/Rectangle Type
  • Application Indoor
  • Casing Polycarbonate
  • Highest Voltage for Equipment (kV) 1.1kV
  • Rated Insulation Level (kV) 1.1/4kVp
  • Rated Primary Current (A) Up to 6000Amps
  • Rated Secondary Current(A) 5A or 1A
  • Accuracy Class of Measuring Core 0.2, 0.5, 1, 3, 5
  • Instrument Safety Factor <=5 (Depending on Accuracy Class)
  • Rated Burden of Measuring Core(VA) Up to 30VA
  • Number of Cores 1
  • Rated Frequency (Hz) 50/60Hz
  • Class of insulation Class A, E and B
  • Applicable Standards IS, IEC, ANSI, BS, etc.
  • Accessories Mounting Clamp or Dinrail or Busbar Supportings
View Complete Details

Low Voltage Indoor Voltage Transformer

  • Min. Order (MOQ) 1 Piece
  • Accuracy Class 0.1 to 3
  • Application Indoor
  • Casting Epoxy Resin/VPI
  • Highest Voltage For Equipment(Kv) Up to 1.1 Kv
  • Rated Insulation Level(Kv) 1.1 / 4kV
  • Rated Frequency(Hz) 50-400Hz
  • No of Phases Single Phase/Three Phase
  • Rated Primary Voltage(V) Up to 1.1kV
  • Rated Secondary Voltage(V) 110V/RT3, 110V/3, 110V(As Per Requirement)
  • Rated Burden(VA) Up to 500VA
  • Accuracy Class of Protection Core 3P and 6P
  • Number of Windings 1-2-3-4-5
  • Class of Insulation Class B, F &H
  • Voltage Factor 1.2 Continuous/1.5 for 30 sec, 1.9 for 8 hours
  • Type of Earthing One End Earthed Type(E‐N) / UN Earthed Type(U‐N)
  • Applicable Standards IS, IEC, ANSI, BS, etc.
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us