Our Products
Spring loaded roller is capable of applying fixed load of 50N (5 Kgs) as per the standard when pressed. Caltechs compact spring loaded roller can be held by hand firmly, easily pressed to get desired load and reduce human errors for applying constant pressure to provide best dust test results. Calibration adjustment is possible simply by adjusting nut. One single broad roller spring loaded roller along with dust test kit helps to accurately determine size and particle size of dust particles on steel surfaces prior to painting. Assure equal pressure for the complete tape to get best results. No maintenance required for this instrument.
Use of spring loaded roller assist to improve adhesion of coating and premature failure of coating. Dust on blast cleaned steel surfaces may reduce the adhesion of applied coatings and by absorbing moisture may promote the corrosion of the blast cleaned steel.
The Paint Inspectors Kit is a comprehensive kit of equipment, which will cater for the day-to-day standard requirements of the Industrial Painter and Inspector.The Paint Inspectors Kits contains the following listed equipment. Paint Inspector Kit in one carrying case with the entire basic test instrument make inspectors job easy. Highly recommended for QA / QC dept. of paint shops
Kit K2002 Contents |
C2200 Coating Thickness Meter with carrying case (Refer various options)F1009 Set of 8 Precision Measured Calibration FoilsZ1003 Steel Zero PlateT2002 Infrared Digital ThermometerH2005 RH%-Dewpoint MeterW2001- Wet Film Gauge (Stainless, range 25m to 1, 500m 45 teeth)R1002 Testex Tape roll (X-Coarse)R1004 Testex Snap GaugeR1003 Burnishing toolR1006 Surface Profile GaugeU1005 Inspection Manual of Coating Defects |
The importance of proper lighting for color matching need not be emphasized due to the phenomenon of Metamerism samples appear to match in one illuminant and mismatch in other illuminants.Scan-O-Lite offers you consistency in illumination, whether it is in the day or night or whether you are examining color in your factory, office or at the customers end.You are assured of uniform and standard illumination. Scan-O-Lite is a very important tool for your modern laboratory and on your shop floor.Immediate visual check for metamerism, fluorescent pigments and strength of optical brighteners etc. changes here
Scan-O-Lite (2 Ft.) | |
Dimensions | Outer – 30 in x 24 in x 30 in Viewing area – 20 in x 19 in x 25 in |
Color of Cabinet | Gray – (Outside) Neutral Gray – (Inside) |
Light Sources: | |
Showroom Illumination | TL84 |
Daylight | D65 |
Incandescent Light | A |
Ultraviolet Light | UV |
Cool White Fluorescent | CWF |
Daylight (5000K) | D-50 |
Simulated Sunlight | |
Cool Day Light |
Type | Marking | Temperature range | |
1 | Denatured Ethanol | DE | -90°C….0°C |
2 | Silicone oil | KDC 200.05 | -40 °C ÷ 130 °C |
3 | Water | W | 10 °C ÷ 95 °C |
4 | Silicone oil | KDC 200.20 | 10 °C ÷ 230 °C |
5 | Silicone oil | KDC 200.50 | 30 °C ÷ 278 °C |
INTERNAL DIMENSION
4 tubes electrical centrifuge basically used Pathological laboratories and hospitals for routine centrifuging tests. These are well known in the market due to their distinctive features like robust Construction, easy to use.
We make use of premium quality material and latest technology machines for the production of this doctor centrifuge by our industry senior most professionals.
Features :
Rust proof Aluminum body.
Best quality rotor with double enameled windings and coil
Fitted with imported carbon brush.
Fitted with vacuum feet for stability.
Single aspirations, with filter (Na K) final result in ppm, 2 digit dual LED display for simultaneous result along with compressor accessories, autoignition, Ca Li filter can be provided on request at extra cost.
Accessories on Request
a)filters (Na, K, Li, Ca) Anyone
b)Air Compressor
Construction:Single walled construction, the wall is made of thick high grade stainless steel sheet of SS304 grade. The lid is made of stainless steel sheet. . Provided with built??? in safety valve, pressure gauge, pressure release valve. The pressure is adjustable from 5 psi to 15 psi .The pressure with an accuracy of
+/- 1 psi. Supplied complete with chord and plug.
Mode of Heating:Electrically heated by special flange type/immersion type. To work on 230 volts singlephase.
Size: 12x12
Alcohol tester is a kind of tester designed to measure concentration result of the breathed alcohol in the human body.
Main Feature:
Advanced Flat surfaced alcohol sensor
Quick Response
SMD assembling, stable performance
Smart MCU control
Direct testing process LCD indication
Digital LCD display with light blue backup
Audio warning beyond preset limit
Sensor fault self checking
CircuitMicroprocessor LSI circuit.
Display61 mm x 34 mm supper large LCD display. 15 mm ( 0.6 ) digit size.
FunctionDual differential input, data hold, zero/relative, memory.
Zero adjustPush button on the front panel.
Operating Temp0 to 50 ( 32 to 122 ).
Operating HumidityLess than 80% R.H.
Features:
The portable anemometer provides fast accurate readings with digital readability and the convenience of a remote sensor separately.
Multi functions for air flow measurement: m/s, km/h, ft/min, knots.
Low friction ball bearing design resulting in accuracy at both high and low velocities.
Conventional twisted vane arms, always a source of unreliability have been eliminated.
DATA HOLD.
Compact housing cabinate.
Wide applications: use this anemometer to check air conditioning heating systems, measure air velocities, wind speeds, temperatureetc.
Detection Distance10 mm for one rupee coin, 120m for iron pipe or tube of 20mm diameter 110mm for a dragger.
Detection SensitivityContinuously adjustable with the help of a knob as per requirements of various applications.
Metal Detection IndicationA unique audio tone beep red LED visual indication indicate presence of metallic object.
Stop Watch Count Timer Mode
Double Count Timer Mode
Display Double Count Timer
Display Time Calendar week and alarm time
Time and Day setting
Alarm time setting
Salient Feature
An Ideal Instrument for use in all industries many other substances coming within the range of the instrument. Dual Scales: Oil Scale 0100 with micrometer
Sugar Scale sub divided at 1% interval so as to measure up to 0.0001.
Transmitted light can be used for transparent solutions. Reflected light for dark or semiopaque substances.
Color in the border line can be eliminated by a compensating prism and the increase in definition obtained gives creator accuracy of measurement.
a) 032%
d) 010%
e) 018%
h) 0100%
028%
*Disp Indoor temperature and humidity, Outdoor temperature;
lay*Record the maximum a minimum temperature and humidity; *Deg. and deg switch;
nd *Freeze from 1 to +4; *Temperature measure range: Indoor: 10+50(+14+122) Outdoor: 50+ (58+158) *Humidity measure range:2099%RH; 70*Accuracy: +/1, +/5%RH; *Time and Alarm
*Battery: 1x 1.5V operation (AAA);
*Figure Size: 110 x 100 x 22 mm
Salient Features:
No lubricant required
Noiseless performance
Absolutely portable
Totally oil free construction
Practically maintenance free
All parts made from special graded Aluminum die cast material for light weight and good strength
Diaphragms are made of special 2 ply nylon reinforced neoprene rubber.
Valves made of SS 316 material
Built in micro suction filter
Extra large bearings for trouble free and smooth running.
These standards describe the determination of colour numbers of mineral hydrocarbons such as undyed motor and aviation gasoline, jet propulsion fuels, naphthas and kerosene and in addition petroleum waxes and pharmaceutical white oils and similar products. The colour allows to draw conclusions upon the refining grade.
Emergency Shower are equipments that are designed to remove contamination from personnel prior to entering a clean room and are available in both standard and customized models. These provides on-the-spot decontamination. Laboratory Emergency Shower are a combination of stainless steel that will be accord with the lustration grade, firm and resistant chemical. These are suitable for cleaning eyes, face, hands, and spray head can be used for washing the whole body. Eye wash and spray shower can be used at the same time or they can be used separately. Switch of the spray shower is placed at the top of the handle and the flow is steady and simple.
Accidental chemical exposures can still occur even with good engineering controls and safety precautions. As a result, it is essential to look beyond the use of goggles, face shields, and procedures for using personal protective equipment. Emergency showers and eyewash stations are a necessary backup to minimize the effects of accident exposure to chemicals.
Emergency Showers can also be used effectively in extinguishing clothing fires or for flushing contaminants off clothing
Laboratory Fume Extractorare widely used for removing smoke, fumes, mist, and fine powder. Mobile fume hood extractor is primarily designed for various pharmaceutical laboratories, various research and development industries and light duty industry. These CE marked equipments are extremely durable, reliable and easy to operate.
it uses an activated carbon filter and fan to remove the smoke, and noxious fumes, created from soldering and other chemical processes.
Fume Extractorincludes a flame-retardant, self-supportive flex arm for easy and varied placement. Other benefits include small footprint, portability handle, heavy-duty casters for easy maneuverability, quick change pre-filter, and a variable speed controller. The product also known asPortable Fume Extractor.
it comes equipped with patented filtration media that is customized specifically for welding fume control. In most cases, HEPA filtration is utilized and is up to 99.97% efficient on particles 0.3 microns and larger. Other options include ASHRAE [up to 95% efficient on particles 0.5 microns and larger] and ULPA filtration media [up to 99.9995% efficient on particles 0.12 microns and larger].
If you are concerned about duct corrosion, hazardous stack emissions or other environmental factors associated with a fume hood you may want to consider a scrubber. Fume Hood Scrubber provides excellent air pollution control for water soluble chemicals present in the laboratory fume hood exhaust fumes. These Scrubber Fume Hood are designed to save space and provide effective air pollution control and operator safety protection for fume hoods. This is especially important for per chloric acid fume hoods, so as to prevent a build-up of potentially explosive perchlorate salts on the exhaust fan, as well as, on the exhaust ducting system.
Controller:Auto tuned PID controller with temperature range up to 200 deg C having
resolution of 0.1 degree centigrade.
Owing to our enriched industrial experiences, we are devoted towards manufacturing a wide variety of excellent qualityChemical Storage Cabinet.
Floor Mounted UCB Ht 675mm with lock skirting based |
UCB/750/2SH/2D |
UCB/1050/2SH/2D |
UCB/450/1D/1SH |
UCB/600/1D/2SH |
UCB/900/1D/1SH |
UCB/750/1D/1SH |
Burn-in ovens are engineered for applications such as high dissipation forward bias, high-temperature reverse bias, dynamic and static burn-in of IC, RAM, ROM, microprocessors and other semiconductor devices.
Integrated Circuits (ICs) and other electronic devices are burned in at elevated temperatures to stress and exercise the devices under test. The high temperatures force early failure, known as infant mortality, at this point rather than later when they are in use in a finished product. This dramatically improves the reliability of the product. During burn-in the temperature rises as the air travels across the chamber due to the heat dissipated by the devices. High volume recirculation fans maintain consistent, uniform temperatures.
Features:
Features:
Basic functions | Range | Basic accuracy |
DC voltage | 400mV/4V/40V/400V/1000V | ± (0.8% 1) |
AC voltage | 4V/40V/400V/750V | ± (1% 5) |
AC bandwidth | 40Hz-400Hz | √ |
DC current | 400 m A/4000 m A/40mA/400mA/4A/10A | ± (1% 2) |
AC current | 400 m A/4000 m A/40mA/400mA/4A/10A | ± (1.5% 5) |
Resistance | 400W / 4k W / 40k W / 400k W / 4M W/40 M W | ± (1% 2) |
Capacitance | 40nF/400nF/4 m F/40 m F/100 m F | ± (3% 5) |
Frequency | 100Hz-10MHz | ± (0.1% 3) |
Temperature | -40 ~ 1000 | ± (1% 3) |
Type | M3900 Digital Multimeter | |
Function | Range | Accuracy |
DC Voltage | 200mV – 1000V | ± (0.5 % + 1dgt) |
AC Voltage | 200mV – 750V | ± (1.5 % + 4dgt) |
DC Voltage | 200µA – 20A | ± (0.5 % + 1dgt) |
AC Voltage | 200µV – 20A | ± (1.0 % + 3dgt) |
Resistance | 200Ω – 20MΩ | ± (0.8 % + 1dgt) |
Diode Test | Yes | |
Transistor Test | Yes | |
Continuity Test | Yes | |
Power Supply | 9V Battery 6F22 | |
Maximum Display | 1999 | |
Products Size | 160 x 82 x 30mm | |
Accessories | Test Lead, Battery, Manual |
Features and Benefits:
Characteristic:
Model/Index | DSO-5025 |
Bandwidth | 25MHZ |
Channel | 2 channels 1 ext trig |
Real Time Sampling | 500MSa/s |
Equivalent Sampling Rate | 10GSa/s |
Memory Depth | 32k |
Rise time | <14ns |
Input Impedance | 1MΩ||17Pf |
Time Base range | 25ns/div-50s/div |
Scan- 100ms-50s/div | |
Vertical Sensitivity | 2mv-10v/div |
Vertical Resolution | 8bit |
Display | 7″(178mm) color TFT(480*234) LCDv |
Gravity Convection Ovens are ideal for applications in which temperature uniformity is not essential, and where samples may otherwise be disturbed by a fan-generated airflow like powders and foils.
These ovens are constructed to remove the moisture as quickly as possible. They are extensively used in various pharmaceutical industries, food processing industries, laboratories and schools. They are incorporated with most developed and latest technology, provided with international safety standards.