Audio and Visual Alarm when HV ON and Off • Test ON and OFF Switch to start and Interrupt Test • Precise Trip Current Setting or Press to Set Switch for Leakage Current • Inbuilt timer with Selector Switch or variable by thumbwheel setting...
Test Voltage DC : 0 to 5000 V continuously variable by multi turn potentiometer AC : 0 to 5000 V continuously variable by multi turn potentiometer (with AC or DC test voltage selector switch) Tripping Current Adjustable 1.0 to 30.0 mA by press to set switch and potentiometer on...
Audio and Visual Alarm when HV ON and Off • Test ON and OFF Switch to start and Interrupt Test • Precise Trip Current Setting or Press to Set Switch for Leakage Current • Inbuilt timer with Selector Switch or variable by thumbwheel setting...
It is used to pin-point underground cable faults in power transmission, distribution cable networks in acoustic mode with the help of suitable surge wave receiver. Key Features Pin-point location of cable faults in Low, Medium and High voltage...
Application It is used to pin-point underground cable faults in power transmission, distribution cable networks in acoustic mode with the help of suitable surge wave receiver. Key Features Pin-point location of cable faults in Low voltage cables by...
Voltage tester, Audio & Visual Alarm when HV on & off. • Test ON & OFF switch to start & interrupt Test. • Precise Trip Current Setting or Press to set switch for Leakage Current. • Inbuilt timer with Selector switch or variable by thumbwheel...
Voltage tester Adjustable 1.0 to 30.0 mA by press to set switch and potentiometer on mA meter OR Test Voltage and leakage current programmable by external 0 to 10 V DC. Audio (Buzzer) and visual (Neon) alarms when HV is ON, Output Trips when breakdown occurs i.e. leakage exceeds...
High Voltage Breakdown Tester Audio and Visual Alarm when HV ON and Off Test ON OFF Switch to Start and Interrupt Test. Unique Data Hold facility to Hold Breakdown Voltage data. Precise Trip Current Setting or Press to Set Switch for Leakage Current Inbuilt Timer with Selector...
Power Requirements : 230 volts AC, ± 10%, 50/60 Hz
Accuracy Of Reading : ±2%
Open Circuit Voltage : 0 to 5 KV or 0 to 10 KVAC. The above voltage can be continuously varied from zero to full value and is continuously monitored by Analog/Digital Panel meter.
: Protection provided with zero start to prevent accident availability of High
Test Current : 5 mAto 50 mA OR 10 mAto 100 mA
Trip settings : The tripping can be reset by a pot which can be varied as peruse requirement
Accuracy of Reading Power : ±2%
Precautions : Voltage on test terminals. High Voltage on test jig appears only after the variac is set to zero and gradually increased. There is a trip device to trip if the current increases than the required value