We offer the best product range of TE2 Temperature Transmitter, Pressure Transmitter, Calorimetric Flow Transmitter, TER8 Temperature Transmitter and PL20H Level Switch.

Pressure Transmitter

  • Application Pressure sensor for general air and gas applications
  • Model Number CTX
  • Measuring range  -1 … 200 bar
  • Min. measuring span  1.0 bar
  • Max. measuring span  200 bar
  • Pressure type  Relative (gauged)
  • Standard error of measurement (BFSL)  ± 0.5 % FSR -Including non-linearity, hysteresis and non-repeatability according BFSL
  • Max. measuring error  ± 2.5 % FSR -Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
  • Temperature coefficient  ≤ 0.15 % FSR/10 K , measuring span ≤ 0.25 % FSR/10 K , zero point
  • Compensated temperature range  -10 … 55 °C
  • Long term stability  ≤ 0.3 % FSR/a
  • Rise time (10 ... 90 %)  ≤ 5 ms
View Complete Details

PBSN Pressure Transmitter

  • Applications for Industrial Applications
  • Measuring range  -1 … 400 bar
  • Min. measuring span  1.0 bar
  • Max. measuring span  400 bar
  • Pressure type  Absolute Relative (gauged)
  • Standard error of measurement (BFSL)  ± 0.3 % FSR , available for measuring spans > 1 bar ± 0.4 % FSR Including non-linearity, hysteresis and non-repeatability according BFSL
  • Max. measuring error  ± 0.5 % FSR , available for measuring spans > 1 bar ± 1 % FSR Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2)
  • Temperature coefficient  ≤ 0.08 % FSR/10 K , measuring span ≤ 0.08 % FSR/10 K , zero point
  • Compensated temperature range  -20 … 60 °C
  • Long term stability  ≤ 0.2 % FSR/a
  • Rise time (10 ... 90 %)  ≤ 5 ms
View Complete Details

PBMN Flush Pressure Transmitter

  • Measuring range  -1 … 400 bar
  • Min. measuring span  0.1 bar
  • Max. measuring span  400 bar
  • Pressure type  Absolute, Relative (gauged)
  • Standard error of measurement (BFSL)  ± 0.04 % FSR , ± 0.1 % FSR ± 0.2 % FSR Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio
  • Max. measuring error  ± 0.1 % FSR, , ± 0.25 % FSR ± 0.5 % FSR Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio
  • Temperature coefficient  ≤ 0.03 % FSR/10 K , measuring span ≤ 0.03 % FSR/10 K , zero point
  • Compensated temperature range  -40 … 85 °C
  • Long term stability  ≤ 0.1 % FSR/a , measuring range > 1 bar ≤ 1 mbar , measuring range ≤ 1 bar
  • Max. turndown ratio  05:01:00 AM
  • Rise time (10 ... 90 %)  ≤ 5 ms
  • IO-Link version  1.1
  • IO-Link port type  Class A
  • Baud rate  38, 4 kbaud (COM2)
  • Cycle time  ≥ 2.3 ms
  • Process data length  24 bit
  • SIO-mode  No
  • Process data (cyclic)  Process pressure
  • Diagnostic data (acyclic)  Process temperature
  • Compliance and approvals Explosion protection 
View Complete Details

PBMN Low Pressure Transmitter

  • Measuring range  -1 … 40 bar
  • Min. measuring span  0.1 bar
  • Max. measuring span  40 bar
  • Pressure type  Absolute Relative (gauged)
  • Standard error of measurement (BFSL)  ± 0.04 % FSR ± 0.1 % FSR Including non-linearity, hysteresis and non-repeatability according BFSL
  • Max. measuring error  ± 0.1 % FSR ± 0.25 % FSR Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio
  • Temperature coefficient  ≤ 0.03 % FSR/10 K , measuring span ≤ 0.03 % FSR/10 K , zero point
  • Compensated temperature range  -40 … 85 °C
  • Long term stability  ≤ 0.1 % FSR/a , measuring range > 1 bar ≤ 1 mbar , measuring range ≤ 1 bar
  • Max. turndown ratio  05:01:00 AM
  • Rise time (10 ... 90 %)  ≤ 5 ms
  • IO-Link version  1.1
  • IO-Link port type  Class A
  • Baud rate  38, 4 kbaud (COM2)
  • Cycle time  ≥ 2.3 ms
  • Process data length  24 bit
  • SIO-mode  No
  • Process data (cyclic)  Process pressure
  • Diagnostic data (acyclic)  Process temperature
  • Explosion protection  ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb ATEX II 1D Ex ia IIIC T107 °C IP6X Da ATEX II 1G Ex ia IIC T4/T6 Ga
View Complete Details

PBMN High Pressure Transmitter

  • Measuring Range 0 … 1600 bar
  • Min. measuring span 60 bar
  • Max. measuring span 1600 bar
  • Pressure type Relative (gauged)
  • Standard error of measurement (BFSL) 0.04 % FSR, 0.1 % FSR, 0.2 % FSR, Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio
  • Max. measuring error ± 0.1 % FSR, ± 0.25 % FSR, ± 0.5 % FSR, Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the applied turndown ratio
  • Temperature coefficient ≤ 0.03 % FSR/10 K , measuring span, ≤ 0.03 % FSR/10 K , zero point
  • Compensated temperature range -40 … 85 °C
  • Long term stability ≤ 0.1 % FSR/a
  • Max. turndown ratio 05:01:00 AM
  • Rise time (10 ... 90 %) ≤ 5 ms
  • Explosion protection ATEX II 1/2G Ex ia IIC T4/T6 Ga/Gb, ATEX II 1D Ex ia IIIC T107 °C IP6X Da, ATEX II 1G Ex ia IIC T4/T6 Ga
View Complete Details

Temperature Transmitter

  • output signal 4 … 20 mA , 2-wire
  • Accuracy < 0.1 % FSR
  • Model Name/Number 2202
  • Degree of protection (EN 60529) IP 40
  • Humidity < 98 % RH , condensing
  • Long-term test (transmitter) IEC 770 6.3.2
  • Vibration (sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
  • Damping 0.0 … 30 s , programmable
  • Temperature drift < 0.003 %/K , typ. < 0.01 %/K , max.
  • Load resistance R = (U - 8 V)/23 mA
  • Resolution 12 bit
  • Up/Down scaling limits 23 mA / 3.5 mA
  • Ripple immunity 3 Vrms
  • Power-up time ≤ 10 s
  • Power supply 8 … 35 V DC
  • Reverse polarity protection Yes
  • Effect of variations in supply voltage < 0.01 %/V
  • TAG No. 15 characters
  • EMC EN 61000-6-2, EN 61000-6-3, EN 61326-1
  • Namur NE21
  • Explosion protection ATEX II 1G Ex ia IIC T5/T6 ATEX II 3G Ex nA IIC T5
View Complete Details

TE2 Temperature Transmitter

  • Process temperature Refer to section "Operating conditions"
  • Pt100 accuracy class (EN 60751) B (± 0.3 °C at 0 °C), ± (0.3 + 0.005 × t)°C, A (± 0.15 °C at 0 °C), ± (0.15 + 0.002 × t)°C, 1/3 B (± 0.1 °C at 0 °C), ± 1/3 × (0.3 + 0.005 × t)°C, 1/6 B (± 0.05 °C at 0 °C), ± 1/6 × (0.3 + 0.005 × t)°C,
  • Thermal response time, T50 RTD element only- ≤ 1.0 s , conical sensor, ≤ 1.3 s , Ø3 mm, ≤ 2.5 s , Ø4 mm, ≤ 3.0 s , Ø6 mm,
  • Process pressure Refer to section "Operating conditions"
  • Sensor length ≤ 3000 mm
  • Sensor tube material AISI 316L (1.4404)
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Degree of protection (EN 60529) IP 65 , with DIN EN 175301-803 A (DIN 43650 A), 4-pin IP 67 , with M12-A, 4-pin
  • Humidity ≤ 100 % RH , condensing
  • Long-term test (transmitter) IEC 770 6.3.2
  • Vibration (sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
  • Without transmitter 1 x Pt100, 4-wire
  • With transmitter 4 … 20 mA , 2-wire
  • EMC EN 61000-6-2, EN 61000-6-3, EN 61326-1, NE21
  • Hygiene FDA (21 CFR 177.2415) 3-A (74-07)
  • Railway applications EN 50155
  • Explosion protection Ex ia Simple apparatus, gas and dust
View Complete Details

TER8 Temperature Transmitter

  • Process temperature 115 … 135 °C , < 1 h -40 … 115 °C , permanent
  • Output range -50 … 150 °C , programmable
  • Min. output span 25 °C
  • Pt100 accuracy class (EN 60751) B (± 0.3 °C at 0 °C), ± (0.3 + 0.005 × t)°C, A (± 0.15 °C at 0 °C), ± (0.15 + 0.002 × t)°C, 1/3 B (± 0.1 °C at 0 °C), ± 1/3 × (0.3 + 0.005 × t)°C, 1/6 B (± 0.05 °C at 0 °C), ± 1/6 × (0.3 + 0.005 × t)°C
  • Max. conversion error ± 0.25 °C
  • Max. output error ± 0.1 % FSR ± 0.016 mA
  • Temperature drift (by ambient) < 0.003 % FSR/°C , typ, < 0.01 % FSR/°C , max.
  • Thermal response time, T90 ≤ 6.5 s , 20 mm, ≤ 6.7 s , 50 mm, ≤ 66.0 s , front-flush
  • Thermal response time, T50 ≤ 2.5 s , 20 mm, ≤ 2.7 s , 50 mm, ≤ 9.0 s , front-flush
  • Sampling interval 0.5 s
  • Immersion length 0 mm , front-flush- 20 mm
  • Sensor tube material AISI 316L (1.4404)
  • Wetted parts material PEEK Natura
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Degree of protection (EN 60529) IP 67 IP 69K , with appropriate cable
  • Humidity < 98 % RH , condensing
  • Vibration (sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
  • Without transmitter 1 x Pt100, 4-wire
  • With transmitter 4 … 20 mA , 2-wire
  • Shunt resistance Rs ≤ (Vs - 8 V)/0.023 A, Rs ≤ 680 Ohm, Vs = 24 V DC
  • EMC EN 61000-6-2, EN 61000-6-3, EN 61326-1
  • Hygiene (EU) No 10/2011, (EC) No 1935/2004, (EC) No 2023/2006, 3-A (74-07), FDA (21 CFR 177.2415)
View Complete Details

TFRH Temperature Transmitter

  • Process temperature Refer to section "Operating conditions"
  • Pt100 accuracy class (EN 60751) B (± 0.3 °C at 0 °C), ± (0.3 + 0.005 × t)°C, A (± 0.15 °C at 0 °C), ± (0.15 + 0.002 × t)°C, 1/3 B (± 0.1 °C at 0 °C), ± 1/3 × (0.3 + 0.005 × t)°C, 1/6 B (± 0.05 °C at 0 °C), ± 1/6 × (0.3 + 0.005 × t)°C
  • Thermal response time, T50 < 1.5 s , Ø4 mm, < 6.1 s , Ø6 mm, ≤ < 7.6 s , Ø8 mm
  • Process pressure Refer to section "Operating conditions"
  • Sensor length 20 … 3000 mm
  • Sensor tube material AISI 316L (1.4404)
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Degree of protection (EN 60529) IP 67 IP 69K , with appropriate cable
  • Humidity < 98 % RH , condensing
  • Vibration (sinusoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / min.
  • Without transmitter 1 x Pt100, 4-wire, 1 x Pt100, 4-wire, 2 x Pt100, 2-wire
  • With transmitter 4 … 20 mA , 2-wire, 4 … 20 mA , 2-wire + HART®
  • EMC EN 61000-6-2, EN 61000-6-3, EN 61326-1
  • Hygiene 3-A (74-07)
  • Explosion protection ATEX II 1G Ex ia IIC T4/T5, ATEX II 3G Ex nA IIC T4/T5, Ex ia Simple apparatus, gas and dust
View Complete Details

LBFI Level Switch

  • Measuring principle CleverLevel level switches (Frequency Sweep)
  • Media characteristics DC > 1.5
  • Hysteresis ± 1 mm
  • Repeatability ± 1 mm
  • Step response time 0.1 s , typ. 0.2 s , max.
  • Damping 0 … 10 s , adjustable
  • Wetted parts material PEEK Natura -AISI 316L (1.4404), AISI 304 (1.4301), optional
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Output type PNP, NPN
  • Switching logic Normally closed (NC), Normally open (NO)
  • EMC Emission EN 61326, installed in a closed metal tank
  • EMC Immunity EN 61326, installed in a closed metal tank
  • Hygiene Refer to section
  • Railway applications EN 50155
  • Safety cULus listed, E365692 WHG (overfill, leakage)
  • Explosion protection ATEX II 1D Ex ta IIIC T100 °C Da, ATEX II 1G Ex ia IIC T4/T5, ATEX II 3G Ex nA IIC T4/T5
View Complete Details

LFFS Level Switch

  • Measuring principle CleverLevel level switches (Frequency Sweep)
  • Media characteristics DC > 1.5
  • Hysteresis ± 1 mm
  • Repeatability ± 1 mm
  • Step response time 0.1 s , typ. 0.2 s , max.
  • Damping 0 … 10 s , adjustable
  • Wetted parts material PEEK Natura- AISI 316L (1.4404), EPDM, optional
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Output type PNP, NPN Digital (push-pull)
  • Switching logic Normally closed (NC), Normally open (NO), Active high, Active low
  • EMC Emission EN 61326, installed in a closed metal tank
  • EMC Immunity EN 61326, installed in a closed metal tank
  • Hygiene Refer to section "Compliance and approvals"
  • Safety cULus listed, E365692 WHG (overfill, leakage)
  • Explosion protection ATEX II 1D Ex tD A20 IP67 T100 °C, ATEX II 1G Ex ia IIC T5, ATEX II 3G Ex nA IIC T5 .
View Complete Details

PFMH Level Switch

  • Measuring Range -1 … 68 bar
  • Min. measuring span 0.05 bar
  • Max. measuring span 69 bar
  • Pressure type Absolute Relative (gauged)
  • Standard error of measurement (BFSL) ± 0.04 % FSR , up to 2:1 turndown ratio, ± 0.1 % FSR , up to 4:1 turndown ratio, Including non-linearity, hysteresis and non-repeatability according BFSL For turndown, multiply this value by the applied turndown ratio
  • Max. measuring error ± 0.1 % FSR , up to 2:1 turndown ratio, ± 0.25 % FSR , up to 4:1 turndown ratio Including zero-point and span error, nonlinearity (by terminal base line), hysteresis and non-repeatability (EN 61298-2) For turndown, multiply this value by the ap
  • Temperature coefficient ≤ 0.05 % FSR/10 K , measuring span ≤ 0.05 % FSR/10 K , zero point
  • Compensated temperature range -40 … 85 °C
  • Long term stability ≤ 0.1 % FSR/a , IEC 770 6.3.2
  • Max. turndown ratio 10:01:00 AM
  • Rise time (10 ... 90 %) ≤ 0.3 s
  • Sample time ≤ 0.3 s
  • Power-up time < 10 s
  • Explosion protection ATEX II 1D Ex ia IIIC T100 °C Da, ATEX II 1G Ex ia IIC T5, ATEX II 3G Ex nA IIC T5
View Complete Details

PL20H Level Switch

  • Trigger modes Adaptive trigger, Window trigger, Analog output
  • Measuring principle CleverLevel level switches (Frequency Sweep)
  • Media characteristics DC > 1.5
  • Hysteresis ± 1 mm
  • Repeatability ± 1 mm
  • Step response time < 150 ms
  • Damping 0 … 10 s , adjustable
  • IO-Link version 1.1
  • IO-Link port type Class A
  • Baud rate 38, 4 kbaud (COM2)
  • Cycle time ≥ 6.4 ms
  • SIO-mode Yes
  • Wetted parts material PEEK Natura AISI 316L (1.4404)
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Output type PNP, NPN, Digital (push-pull) 4.20 mA
  • Switching logic Normally closed (NC), Normally open (NO), Active high, Active low
  • EMC Emission EN 61326-1, EN 50121-3-2:2016
  • EMC Immunity EN 61326-1, EN 50121-3-2:2016
  • Hygiene 3-A (74-07), EHEDG EL Class I FDA (21 CFR 177.2415)
  • Safety cULus listed, E365692
View Complete Details

Calorimetric Flow Transmitter

  • Measuring range, flow 10 … 400 cm/s
  • Measuring range, temperature -25 … 150 °C
  • Max. measuring error ± 2 % FSR , flow measurement, ± 8 cm/s , flow measurement, ± 1 °C , temperature measurement @ flow > 0 cm/s
  • Step response time 25 °C , adjustable
  • Repeatability < 5 s
  • Down time at temperature step < 10 s
  • Wetted parts material AISI 316L (1.4404)
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Degree of protection (EN 60529) IP 67, IP 68 , 30 min. @ 1 mH2O, IP 69K , with appropriate cable
  • Shock (EN 60068-2-27) 30 g / 11 ms, 6 impulses per axis and direction
  • Vibration (sinusoidal) (EN 60068-2-6) 5 g (10 . 2000 Hz)
  • Current output 4 … 20 mA
  • Voltage output 0 … 10 V
  • Output type Digital (push-pull), NPN, PNP
  • Switching logic Active high, Active low, Normally closed (NC), Normally open (NO)
  • Interface IO-Link 1.1
  • Hygiene FDA compliant , EHEDG EL Class I
  • Model PF20H
View Complete Details

AFI4 Conductivity Transmitter

  • Conductivity 14 selectable ranges
  • Temperature Compensation 0.0 … 5.0 % FSR/K , adjustable
  • Min. measurable conductivity 50 µS/cm
  • Max. measuring span 1000 mS/cm
  • Min. measuring span 500 µS/cm
  • Max. measuring error ± 1.0 % FSR , 0 … 1 mS/cm to 0 … 500 mS/cm ± 1.5 % FSR , 0 … 1000 mS/cm ± 1.5 % FSR , 0 … 500 µS/cm
  • Reference temperature 25 °C , adjustable
  • Repeatability < 0.5 % FSR , > 1 mS/cm
  • Compensated temperature range -20 … 150 °C
  • Step response time ≤ 2.0 s
  • Sample time ≤ 0.4 s
  • Concentration 4 factory set media
  • Customer defined media Customer defined (30 point lookup table)
  • Temperature Free programmable range
  • Measuring range -20 … 150 °C
  • Thermal response time, T90 ≤ 15 s
  • Max. measuring error ± 0.4 K
  • Process temperature -20 … 140 °C , permanent 140 … 150 °C , max. t < 1 h
  • Process pressure ≤ 25 bar
  • Connection variants G 1 A hygienic
  • Wetted parts material PEEK Natura
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Properties Universal commands Common-practice commands Conductivity device family commands Device Specific Commands For more information please see ‚HART Field Device Specification‘
  • Protocol HCF standard, Rev.7
  • IO-Link version 1.1
  • Device profile Smart Sensor Profile
  • Baud rate 38, 4 kbaud (COM2)
  • Cycle time ≥ 8, 4 ms
  • Process data length 128 bit
  • SIO-mode Yes
  • Process data (cyclic) Switch state Signal analog output 1 Signal analog output 2 Temperature Unit temperature Conductivity Concentration Actual measuring range
  • Degree of protection (EN 60529) IP 67 IP 69K , with appropriate cable
  • EMC EN 61326-1
  • Hygiene 3-A (74-07) EHEDG EL Class I FDA (21 CFR 177.2415)
  • Safety cULus listed, E491206
View Complete Details

AFI5 Conductivity Transmitter

  • Conductivity 14 selectable ranges
  • Temperature Compensation 0.0 … 5.0 % FSR/K , adjustable
  • Material PUR
  • Min. measurable conductivity 50 µS/cm
  • Max. measuring span 1000 mS/cm
  • Min. measuring span 500 µS/cm
  • Max. measuring error ± 1.0 % FSR , 0 … 1 mS/cm to 0 … 500 mS/cm ± 1.5 % FSR , 0 … 1000 mS/cm ± 1.5 % FSR , 0 … 500 µS/cm
  • Reference temperature 25 °C , adjustable
  • Repeatability < 0.5 % FSR , > 1 mS/cm
  • Compensated temperature range -20 … 150 °C
  • Step response time ≤ 2.0 s
  • Sample time ≤ 0.4 s
  • Concentration 4 factory set media
  • Customer defined media Customer defined (30 point lookup table)
  • Temperature Free programmable range
  • Measuring range -20 … 150 °C
  • Thermal response time, T90 ≤ 15 s
  • Max. measuring error ± 0.4 K
  • Process temperature -20 … 140 °C , permanent 140 … 150 °C , max. t < 1 h
  • Process pressure ≤ 25 bar
  • Connection variants G 1 A hygienic
  • Wetted parts material PEEK Natura
  • Surface roughness wetted parts Ra ≤ 0.8 µm
  • Properties Universal commands Common-practice commands Conductivity device family commands Device Specific Commands For more information please see ‚HART Field Device Specification‘
  • Protocol HCF standard, Rev.7
  • IO-Link version 1.1
  • Device profile Smart Sensor Profile
  • Baud rate 38, 4 kbaud (COM2)
  • Cycle time ≥ 8, 4 ms
  • Process data length 128 bit
  • SIO-mode Yes
  • Process data (cyclic) Switch state Signal analog output 1 Signal analog output 2 Temperature Unit temperature Conductivity Concentration Actual measuring range
  • Degree of protection (EN 60529) IP 67 IP 69K , with appropriate cable
  • Cable lengths 10.0 m 5.0 m 2.5 m
  • Temperature -40 … 80 °C
  • EMC EN 61326-1
  • Hygiene 3-A (74-07) EHEDG EL Class I FDA (21 CFR 177.2415)
  • Safety cULus listed, E491206