Our Products
WEIBEREntomology Chamberprovides precise control of a wide range of environmental climate conditions for propagation and study of insects. The low profile, side mounted lighting system allows full utilization of the chamber interior and complete access to the sliding shelves is an added design feature of ourEntomological Test Chamber. Combines state of the art technology with a highly efficient design to provide a reliable solution to the insect rearing problems and other entomological research studies.
The chamber can be used to study and store Drosophila, bees, mosquitoes and other types of insects, all within a controllable environment. Supplied with illuminated shelves and a customized growth areas, users can select additional shelves to be fitted in the chamber. The illuminated shelves are fitted with banks of high frequency lighting, minimizing the effects of stroboscopic stress on insects.
Chamber volume | 1200 litre |
Interior dimensions (w x d x h) | 1310mm x 675mm x 1410mm |
Exterior dimensions (w x d x h) | 1440mm x 810mm x 1975mm |
Customizable sizes are also available.
Temperature Range - lights Off2 | 10 to 60°C, adjustable |
Temperature Range - Lights on2 | 0.5°C |
Temperature Fluctuation with Time | 40 to 95%RH |
Humidity Range | ±2%RH |
Humidity sensitivity | HMI+PLC |
Three shelves: Fluorescent tubes per shelf Maximum lighting intensity1 Maximum height between shelves Maximum shelving area |
4x 36W 170 µmol m-2s-1 350mm 2.04m2 |
Electrical connection | 230V ±10%, 50/60Hz, Single Phase L-N, 13A |
Weight (empty chamber) | 275kg |
Fume Hoodsare equipments that are used to ensure safety for the user as they wont be exposed to too many hazardous and dangerous fumes.Fume Hoodcapture the fumes/effluents released during any given experiment, contain them in the enclosure and then emit through their well-designed exhaust system.
We specialize in standardFume Hoodand customizedChemical Fume Hood.Fume hoods typically protect only the user, and are most commonly used in laboratories where hazardous or noxious chemicals are released during testing, research, development or teaching. They are also used in industrial applications or other activities where hazardous or noxious vapors, gases or dusts are generated or released.
Constructions | thick PCRC, pre coated corrosion resistant GI sheet |
Table | Stainless steel sheet table of ss-304 grade/ fortified acid proof glazed tiles |
Sink | Stainless steel sink with tap |
Coating | Epoxy coating/ FRP lined |
Air flow | Unidirectional |
Air flow control | Three step air flow speed controller |
Blower assembly | Centrifugal lubricated bearing type ISI marked assembly |
Illumination | Fluorescent light illumination greater than 800 lux on work table. |
Noise level | Noise level less than 60 db |
Power requirements | 500 watts -750 watts( model specific) |
Nominal voltage | 220- 230 volts, 50Hz single phase |
Frequency | 50 |
Ceiling Fume Hoodare designed to collect and exhaust corrosive vapors, heat, steam, and odors when mounted over areas with water baths, hot plates, or portable equipment. Because it mounts on the wall above your work bench, it wont require any floor space. Simply connect the discharge to your in-house ventilation system. An integral high-airflow baffle with filters conducts the gas flow into the hood.Roof Mounted Fume Hoodare developed and designed to be used as semiconductor ventilated enclosures so as to protect the user from harmful and toxic fumes and vapors and to eliminate the possibility of accidental fire which may lead to emission of inflammable gases during the course of experiments.
Constructions | Thick PCRC/SS-304/Polypropylene |
Coating | Epoxy coating/ FRP lined |
Air flow control | Three step air flow speed controller |
Blower assembly | Centrifugal lubricated bearing type ISI marked assembly |
Illumination | Fluorescent light illumination greater than 800 lux on work table. |
Noise level | Noise level less than 60 d |
Power requirements | 500 watts -750 watts( model specific) |
Nominal voltage | 220- 230 volts, 50Hz single phase |
Frequency | 50 |
Walk in fume hood is a regarded as a great way to handle odors and toxic fumes from processing units and distillation assemblies. These floor standing fume hoods can feature services like air, gas, nitrogen or any other type of gas. Weiber mobile fume hoods are ducted or ductless as per choice, microprocessor based, advanced and CE marked equipments are designed for both laboratory and industrial application like:
Constructions | thick PCRC, pre coated corrosion resistant GI sheet |
Table | Stainless steel sheet table of ss-304 grade/ fortified acid proof glazed tiles |
Sink | Stainless steel sink with tap |
Coating | Epoxy coating/ FRP lined |
Air flow | Unidirectional |
Air flow control | Three step air flow speed controller |
Blower assembly | Centrifugal lubricated bearing type ISI marked assembly |
Illumination | Fluorescent light illumination greater than 800 lux on work table. |
Noise level | Noise level less than 60 db |
Power requirements | 500 watts -750 watts( model specific) |
Nominal voltage | 220- 230 volts, 50Hz single phase |
Frequency | 50 |
WORKING SIZES
Size WXHXD | HOOD SIZE WXH |
48” X 93” X 35” | 38”X 72” |
60” X 93” X 35” | 50”X 72” |
72”X 93”X 35” | 62”X 72” |
96”X 93”X 35” | 86” X72” |
Ductless Fume Hoodprovide protection to both laboratory personnel and the environment from toxic fumes.Ductless fume hoodsare considered as independent systems that do not require connection to the extraction systems. Unlike conventional fume hoods, these hoods filter out chemical fumes and recycle air directly back to the laboratory, providing energy savings, personnel and environmental protection, convenience as you do not have to deal with complicated ducting systems, and mobility, since ductless hoods are independent systems which do not require connection to extraction systems.
With aDuctless Fume Hoodit is essential that the filter medium be able to remove the particular hazardous or noxious material being used. As different filters are required for different materials, recirculatingfume hoodsshould only be used when the hazard is well known and does not change.
WORKING SIZES
Model no | Dimension (length x depth x height) |
Acm- Cafh-1200 | 4’ x 2’ x 2’ |
Acm -Cafh-1503 | 5’ x 21/2 x 21/2 |
Acm - Cafh 1803 | 6’ x 3’ x 3’ |
CUSTOMIZABLE SIZES ARE ALSO AVAILABLE
Constructions | thick PCRC, pre coated corrosion resistant GI sheet |
Table | Stainless steel sheet table of ss-304 grade/ fortified acid proof glazed tiles |
Sink | Stainless steel sink with tap |
Coating | Epoxy coating/ FRP lined |
Air flow | Unidirectional |
Air flow control | Three step air flow speed controller |
Blower assembly | Centrifugal lubricated bearing type ISI marked assembly |
Illumination | Fluorescent light illumination greater than 800 lux on work table. |
Noise level | Noise level less than 60 db |
Power requirements | 500 watts -750 watts( model specific) |
Nominal voltage | 220- 230 volts, 50Hz single phase |
Frequency | 50 |
Polypropylene Fume Hoodfor high acid and trace metal analysis use. WEIBER offers a range ofPp Fume Hoodconstructed from all white stress-relieved, acid resistant, non-corrosive polypropylene. These hoods are specially engineered for use with harsh corrosive acids. They are available as conventional total exhaust hoods providing only operator protection, and as HEPA-filtered laminar flow fume hoods providing both operator and product protection.
Constructed almost entirely of polypropylene, this fume hood contains the Zero Leak Airflow System, available only from. The system prevents uneven particulate loading by eliminating direct blasts to the HEPA filter, dispensing air over 100% of the surface. These cabinets meet Federal Standard 209e, Class 10 air quality conditions, and have been independently tested for containment properties in accordance to ASHRAE Standard 110-1995 for Fume Hoods.
Working dimensions (WXDXH)mm | Weight kg |
1232*914*1718 | 320 |
1537*914*1718 | 332 |
1842*914*1718 | 375 |
2451*914*1718 | 575 |
Exterior and interior construction | Structural polypropylene |
Exhaust | 500 cFM-1250cFM |
Static exhaust | 20mm-38mm |
Exhaust duct | 102*610 mm |
Power requirements | 230V, 50 Hz |
Down Flow Velocity 105 LFPM | 60 LFPM (0.30 m/s) |
Inflow Velocity | 105 LFPM (0.53 m/s) |
Centrifugation is a process that involves the use of the centrifugal force for the separation of mixtures, used in industry and in laboratory settings. More-dense components of the mixture migrate away from the axis of the centrifuge, while less-dense components of the mixture migrate towards the axis.
Computer ControlledHigh Speed Refrigerated Centrifugeare useful for centrifugation of temperature sensitive material and find applications in routine and research work in auxiliary laboratories in industry, Educational & Research institutions, Bio Technology, Medical Laboratories, Hospitals, Blood Banks, Pharmaceutical laboratories etc. Brushless induction motor with frequency drive & unique automatic rotor identification ensures accurate speed setting for individual rotors. Over current overheating safety cut off circuit is provided for motor protection. Safety lid interlock on the centrifuge ensures that the rotor does not run with cover open while the cover cannot be opened unless rotor comes to complete halt. A unique safety feature of automatic rotor identification ensures proper speed setting for individual rotors to avoid danger of over speed running. Advanced manufacturing techniques are used for resilient mounting of heavy-duty brushless induction motor resulting in low level of vibration and noise. The products also knowns asHigh Speed Cooling CentrifugeandHigh Speed Low Temperature Centrifuge.
Max speed | 25000r/min |
Max RCF | 64800xg (24x1.5/2ml 25000r/min) |
Max capacity | 4x1000ml |
Speed accuracy | +/-30r/min |
Acc/Dec time | The time of Acc/Dec can be set freely |
The fastest Acc time | 1min30s(0-25000r/min) |
The fastest Dec time | 1min40s(25000r/min-0) |
Temperature setting range | -20OC TO -40OC |
Temperature accuracy | +/- 1 degree |
Refrigeration system | Non-Freon Refrigeration System |
Time range | 0-23h59min |
Power supply | AC220V 50Hz |
Noise | Lower than 65dB(A) |
Dimension | 710x820x950mm(LxWxH) |
Weight | 290kg |
Rotor
Number | Rotor | Speed(RPM) | RCF(XG) | Capacity | Remark |
NO1 | Angle rotor | 25000 | 64800 | 24x1.5/2ml | Aluminum alloy |
NO2 | Angle rotor | 23000 | 60460 | 18x10ml | Aluminum alloy |
NO3 | Angle rotor | 21000 | 52356 | 8x50ml | Aluminum alloy |
21000 | 52356 | Titanium alloy | |||
NO4 | Angle rotor | 15000 | 33800 | 4x250ml | Aluminum alloy |
NO5 | Angle rotor | 14000 | 30070 | 6x250ml | Aluminum alloy |
NO6 | Angle rotor | 10000 | 17700 | 6x500ml | Aluminum alloy |
NO7 | Angle rotor | 8000 | 12040 | 4x1000ml | Aluminum alloy |
NO8 | Swing rotor | 5000 | 5470 | 4x750ml | |
NO9 | Micro plate Rotor | 4000 | 3040 | 4x2x96 well | |
NO10 |
Swing rotor | 10000 | 15680 | 6x50ml | Aluminum alloy |
NO11 | Angle rotor | 14000 | 30070 | 12x50ml | Aluminum alloy |
High Capacity Refrigerated Centrifuge which are manufactured as per the industrial standards by using hi-tech facilities. These are tested stringently for quality before getting supplied to the clients to ensure that they get nothing but the best. Moreover, these can be provided to the clients in customized sizes and specifications as per their requirements. A Large Capacity Refrigerated Centrifuge is a piece of equipment that puts an object in rotation around a fixed axis, applying a force perpendicular to the axis. The High Capacity Cooling Centrifuge works using the sedimentation principle, where the centripetal acceleration causes denser substances to separate out along the radial direction. Its widely used in field of radicalization immunity, biochemistry, biologic pharmacy, blood separation and purification.
Max speed | 6000r/min |
Max RCF | 6680xg |
No 1 Angle Rotor | 6x500ml (6000r/min RCF:6680xg) |
No 2 Swing Rotor | 6x1000ml (4200r/min RCF:5100xg) |
Speed control accuracy | +/- 50r/min |
Acc/Dec rates | The Acc/Dec time can be set freely |
Temperature setting range | -20C~40C |
Temperature control accuracy | +/- 1C |
Refrigeration system | Non-CFC Refrigeration System |
Control | PC control |
Noise level | <65dB(A) |
Time setting range | 0-23h59min |
Motor | AC frequency conversion motor |
Power supply | AC220V50Hz30A |
Dimension | 730x840x1200mm(LxWxH) |
Weight | 260kg |
Table Top Oil Test Centrifugeis designed according to water and deposit determining in a crude oil. It can be used for moisture determining in oil exploration and in research institutes. The range of centrifuge is specially designed for use in Oil Testing for tests as per ASTM and IP standards.
By making use of the principle of centrifugal settling, WeiberTable Top Oil Centrifugeis used for separating, concentrating and purifying the particles with different densities in solution. The constituents of main frame include shell, centrifugal chamber, driving system, control system and operating display unit. In addition, rotor and centrifugal tube are provided as accessories. The products also knowns asOil Test CentrifugeandOil Centrifuge.
Max speed | 4000r/min |
Max capacity | No.1 swing rotor 28X10ml (4000rpm, 2498 Xg) No.2 swing rotor 4X100ml (1700rpm, 940 Xg) No.3 swing rotor 4X100ml (3000rpm, 2062 Xg) |
Temperature setting range | Roomtemperature+10 degree to 65 degree |
Time range | 0-99min |
Noise | lower than 65dB(A) |
Dimension | 520X550X400mm(LXWXH) |
Weight | 85kg |
Dairy Test Centrifugeis used in measurement and analysis fat in dairy products separation by making use of pasteurization and Gerber. It is mainly used in degreasing and clarifying of milk. It is also known asMilk CentrifugeandDairy Centrifuge.
Max speed | 3000r/min | |
No1 angle rotor | 8x30ml(Gerber tube) 1400r/min RCF:350xg | |
No2 swing rotor | 4x50ml(Diary bottle) 3000 r/min RCF:1810xg | |
Max RCF | 1810xg | |
Temperature setting range | Room temperature 10 degree to 65degree | |
Power supply | AC220V 50Hz 10A | AC220V 50Hz 5A |
Noise | lower than 60dB(A) | |
Time range | 0-99min | |
Dimension | 590x710x1140mm (LxWxH) |
450x520x370mm (LxWxH) |
Weight | 150kg | 30kg |
High speed centrifugespins liquid samples at high speed. All Benchtop Centrifuges have soft touch keypads for fast and accurate setting of run parameters. A wide variety of swing out and angle rotors with a choice of reduction adaptors make these units truly versatile. All the centrifuges have rust proof, easy to clean Stainless Steel centrifuge inner chamber with steel guard. High Speed Refrigerated Centrifuge offers significant application in Blood Banking, Bio-Processing labs, Clinical Applications, Fast Sample Processing, High Productivity, Sedimentation, Medical Research, Satellite Blood Processing Centers, Micro Biological and Molecular Biology. It additionally provides the cooling mechanism to maintain the uniform temperature throughout the operation of the sample.
Model | ACM-CFG-54234 |
Max speed | 18500r/min |
Max RCF | 23797xg |
Max capacity | 120 ml |
Speed Control accuracy | +/- 50r/min |
Temperature setting range | -20C--40C |
Temperature Control accuracy | +/-1.5C |
Time Setting range | 9H59min |
Noise level | <65dB(A) |
Motor | AC frequency conversion motor |
Power supply | AC220V 50Hz 15A |
Dimension | 560x810x430(mm) |
Weight | 90kg |
Rotor
Rotor | Max speed | Max RCF | Capacity |
NO1 Angle rotor | 18500 | 23797 | 12x1.5/2.2ml |
NO2 Angle rotor | 12000 | 13200 | 8x15ml(conical bottom) |
NO3 Angle rotor | 13000 | 17370 | 12x10ml (5ml adapter) |
NO4 Angle rotor | 12000 | 15285 | 6x50ml |
Tabletop Low Speed Centrifuge is a versatile centrifuge is ideal for biology and cell or tissue culture laboratories. This is equipped with Soft Start/Stop for gentle acceleration and deceleration, auto-alarm system for rotor imbalance, over heat and over speed, and with automatic lid release. By making use of the principle of centrifugal settling, Weiber tabletop low-speed centrifuge is used for separating, concentrating and purifying the particles with different densities in solution.
It consists of main frame and accessories, of which the constituents of main frame include shell, centrifugal chamber, driving system, control system and operating display unit. In addition, rotor and centrifugal tube are its accessories.This machine adopts brushless motor drive, microcomputer control, protection of lid, realize the convenient operation. It is applied to separate the particles with different densities in various scientific research labs and Industries.
Max. Speed | 4000r/min |
Max. RCF | 5030xg |
Max. capacity | 240ml |
Control | Microprocessor control |
Display screen | LED / LCD (by user's choice) |
Speed control accuracy | +/- 30r/min |
The shortest Acc/Dec time | 100r/min-5000r/min<45s/ 5000r/min-100r/min<50s |
Time setting range | 1s-99min 59s or continuous or hold |
Temperature setting range | -20C--40C |
Temperature control accuracy | +/-1.5C |
Refrigeration system | Non-Freon Refrigeration System |
Power supply | AC220V +/-10%50Hz 15A |
Noise level | <65dB(A) |
Dimension | 800x680x450(mm) |
Weight | 95kg |
Rotor
Rotor | Max speed | Max RCF | Capacity | Tube Size | Tube type | ||
NO 1 | Angle rotor | 5350 | 5030 | 6x50ml | 30x110 | PP | |
NO2 | Swing rotor | 4000 | 3040 | 4x500ml | 500ml bottle | PP | |
Adapter | 4x250ml | 62x124 | PP | ||||
Adapter | 4x3x50ml | 30x100--130 | PP(conical or round bottom) | ||||
Adapter | 4x7x20ml | 20x100--115 | PP | ||||
Adapter | 4x9x15ml | 17x105 | PP(conical or round bottom) | ||||
Adapter | 4x19x5ml | 14x100 | Vacuum blood tube | ||||
Bucket | 4000 | 3040 | 4x37x5ml | 13x70 | G radio-immunity tube | ||
4x24x7ml | 13x70--100 | Vacuum Blood tube | |||||
Rectangular Bucket | Adapter | 4000 | 3040 | 4x4x50ml | 30x100--130 | PP (conical or round bottom) | |
Adapter | 4x10x15ml | 17x105 | PP (conical or round bottom) | ||||
Adapter | 4x20x10ml | 14x100 | Vacuum blood tube | ||||
Adapter | 4x28x5ml | 14x80--100 | Vacuum blood tube | ||||
Adapter | 4x25x1.5ml | Eppendorf tube | |||||
Rectangular bucket for Micro plate | 4000 | 3040 | 4x2x96well | 96 well Microplate | |||
NO3 | Micro plate rotor | 4000 | 2200 | 2x2x96 well | 96 well Microplate | ||
NO4 | Swing rotor | 4000 | 3500 | 4x750ml | 98x130 | 750ml centrifugal bottle | |
Adapter | 4000 | 3500 | 4x2x100ml | 42x100 | PP Round bottom | ||
Adapter | 4000 | 3500 | 4x4x50ml | 30x100--120 | PP conical or round bottom |
||
Adapter | 4000 | 3500 | 4x10x20ml | 20x100--115 | PP | ||
Adapter | 4000 | 3500 | 4x14x15ml | 17x120 | PP conical bottom | ||
Adapter | 4000 | 3500 | 4x19x15ml | 17x100--120 | PP Round bottle (without screw cap) | ||
Adapter | 4000 | 3500 | 4x24x7ml | 13x70--100 | Vacuum Blood tube | ||
Adapter | 4000 | 3500 | 4x37x5ml | 13x70 | G RIA-tubes | ||
NO5 | Swing rotor | 4200 | 3500 | 6x250ml | 62x124 | PP Flat bottom | |
Adapter | 4200 | 3500 | 6x10x5ml | 13x100 | Vacuum blood tube | ||
Adapter | 4200 | 3500 | 6x7x10ml | 15x100 | Vacuum blood tube | ||
Adapter | 4200 | 3500 | 6x6x15ml | 17x105 | G/PP round bottom | ||
Adapter | 4200 | 3500 | 6x4x15ml | 17x120 | conical bottom with scale | ||
Adapter | 4200 | 3500 | 6x50ml | 30x100--120 | PP Round or conical bottom |
Low-speed centrifuges featuring dependable performance to meet the most demanding low speed, high capacity applications. Unparalleled reliability with reproducible separations for blood banking and large volume processing. It is also known asLaboratory Centrifuge, Large Capacity Centrifuge, andHigh Capacity Centrifuge.
Max. Speed | 5350r/min |
Max. RCF | 5030xg |
Max. capacity | 4x750ml |
Control | Microprocessor control |
Display screen | LED / LCD (by user's choice) |
Speed control accuracy | +/- 30r/min |
The shortest Acc/Dec time | 100r/min-5000r/min<45s/ 5000r/min-100r/min<50s |
Time setting range | 1s-99min 59s or continuous |
Refrigeration system | No refrigeration |
Power supply | AC220V +/-10%50Hz 15A |
Noise level | <65dB(A) |
Dimension | 580x800x900(mm) |
Weight | 70kg |
Rotor
Rotor | Max speed | Max RCF | Capacity | Tube Size | Tube type | ||
NO 1 | Angle rotor | 5350 | 5030 | 6x50ml | 30x110 | PP | |
NO2 | Swing rotor | 4000 | 3040 | 4x500ml | 500ml bottle | PP | |
Adapter | 4x250ml | 62x124 | PP | ||||
Adapter | 4x3x50ml | 30x100--130 | PP(conical or round bottom) | ||||
Adapter | 4x7x20ml | 20x100--115 | PP | ||||
Adapter | 4x9x15ml | 17x105 | PP(conical or round bottom) | ||||
Adapter | 4x19x5ml | 14x100 | Vacuum blood tube | ||||
Bucket | 4000 | 3040 | 4x37x5ml | 13x70 | G radio-immunity tube | ||
4x24x7ml | 13x70--100 | Vacuum Blood tube | |||||
Rectangular Bucket | Adapter | 4000 | 3040 | 4x4x50ml | 30x100--130 | PP (conical or round bottom) | |
Adapter | 4x10x15ml | 17x105 | PP (conical or round bottom) | ||||
Adapter | 4x20x10ml | 14x100 | Vacuum blood tube | ||||
Adapter | 4x28x5ml | 14x80--100 | Vacuum blood tube | ||||
Adapter | 4x25x1.5ml | Eppendorf tube | |||||
Rectangular bucket for Micro plate | 4000 | 3040 | 4x2x96well | 96 well Microplate | |||
NO3 | Micro plate rotor | 4000 | 2200 | 2x2x96 well | 96 well Microplate | ||
NO4 | Swing rotor | 4000 | 3500 | 4x750ml | 98x130 | 750ml centrifugal bottle | |
Adapter | 4000 | 3500 | 4x2x100ml | 42x100 | PP Round bottom | ||
Adapter | 4000 | 3500 | 4x4x50ml | 30x100--120 | PP conical or round bottom |
||
Adapter | 4000 | 3500 | 4x10x20ml | 20x100--115 | PP | ||
Adapter | 4000 | 3500 | 4x14x15ml | 17x120 | PP conical bottom | ||
Adapter | 4000 | 3500 | 4x19x15ml | 17x100--120 | PP Round bottle (without screw cap) | ||
Adapter | 4000 | 3500 | 4x24x7ml | 13x70--100 | Vacuum Blood tube | ||
Adapter | 4000 | 3500 | 4x37x5ml | 13x70 | G RIA-tubes | ||
NO5 | Swing rotor | 4200 | 3500 | 6x250ml | 62x124 | PP Flat bottom | |
Adapter | 4200 | 3500 | 6x10x5ml | 13x100 | Vacuum blood tube | ||
Adapter | 4200 | 3500 | 6x7x10ml | 15x100 | Vacuum blood tube | ||
Adapter | 4200 | 3500 | 6x6x15ml | 17x105 | G/PP round bottom | ||
Adapter | 4200 | 3500 | 6x4x15ml | 17x120 | conical bottom with scale | ||
Adapter | 4200 | 3500 | 6x50ml | 30x100--120 | PP Round or conical bottom |
Bench top Urine Sediment Separation Centrifuge is a urine sediment analyzer, and its characterized by high efficiency, multiple-pipe support and good effect in separation. A centrifuge is a piece of equipment that puts an object in rotation around a fixed axis, applying a force perpendicular to the axis. The centrifuge works using the sedimentation principle, where the centripetal acceleration causes denser substances to separate out along the radial direction. Its widely used in field of radicalization immunity, biochemistry, biologic pharmacy, blood separation and purification. The Centrifuge also known asUrine CentrifugeandBench Top Medical Centrifuge.
Max speed | 4000r/min |
Max RCF | 2800xg |
swing rotor | (32x15ml)Urine sediment falcon tube with scale |
Motor | DC brushless motor, Microprocessor control |
Time range | 0-99min |
Power supply | AC220V 50Hz 5A |
Dimension | 430x490x380mm(LxWxH) |
Weight | 46kg |
Cell Smear Centrifugeis used to take erythrocyte-serum test, identify antigens and antibodies, and give other relative tests in immune hematology examination and research laboratories. It is controlled by microprocessor, equipped with D.C. Brushless motor, digital display and low noise. The Centrifuge also known asMedical CentrifugeandTable Top Medical Centrifuge.
Max speed | 3000r/min |
Max RCF | 730xg |
Amount of single tube | 0.1ml-0.5ml |
Count of all tubes | 6 |
Motor | DC brushless motor, Microprocessor control |
Power supply | AC220V 50Hz 3A |
Dimension | 300x280x270mm (LxWxH) |
Weight | 15kg |
Immunity Blood Centrifuge is for erythrocyte washing and for lymphocyte washing. This Centrifuge also known asBlood Bank Centrifuge, Blood CentrifugeandPathology Centrifuge.
Max speed | 4500r/m | 3000r/m |
Max RCF | 2000xg | 1000xg |
Rotor capacity | 12x(0.25-1ml) | 12x7ml (10-13x65-100mm) |
Control | Microprocessor control, DC brushless Motor | |
Time setting range | Electric timing (programmed) | |
Noise level | <60dB(A) | |
Power supply | AC220V 50Hz 2A | |
Dimension | 380x320x245mm(LxWxH) | |
Weight | 16kg |
Rotor | Key | RCF | Time | Use |
HLA rotor for lymphocyte washing | 1 | Lymphocyte separation, Incubated cell separation | ||
2 | 1000xg | 3s | Hematoblast exenterate(thrombin disposal) | |
3 | 1000xg | 60s | Lymphocyte washing | |
SERO rotor for erythrocyte washing | 1 | 500xg | 60s | Blood type determination, the image of the hematocyte |
2 | 1000xg | 15s | The testing of intersectant aptness | |
3 | 1000xg | 60s | Hematocyte washing, the distillation of the serum and plasma |
Bench top Filtration Centrifuge is drived by DC motor with brushless and controlled by computer, with low noise and no carbon powder pollution. The centrifugal rotor and centrifugal room are all made of stainless steel and cover is sealed with silicon rubber sealing strips so as to be resist- ant to corrosion. In addition, it can be disinfected with many methods. Special structural design makes continuous separation possible and from an automatic separation filtration system together with other parts, resulting in the filtration efficiency greatly increased. It is supplied with the standard filter bags to facilitate the users.
Max. speed | 4000r/min | 5000r/min |
Max. RCF | 3800xg | 4100xg |
Max. capacity | 10L/min | 8L/min |
Time setting range | 0~99min | 0~99min |
Motor | DC brushless motor, Microprocessor control | DC brushless motor, Microprocessor control |
Power supply | AC220V 50Hz 5A | AC220V 50Hz 3A |
Dimension | 380x400x350mm(LxWxH) | 320x380x350mm(LxWxH) |
Weight | 36kg | 28kg |
Microhematocrit Centrifugecan be used to determine the specific product value of blood cell and separate the micro-blood from micro-solution. It is made of formed metal and has a baked paint application that is acid and reagent resistant. A safety switch built into the handle assembly disconnects the power to the motor whenever the latch is lifted. The hematocrit tray is made of plastic composite material backed by an aluminum shell for durability and lighter weight. The brushed motor is mounted on rubber mounts to provide quieter running and less vibration Cleaned and disinfected. It is also known asHematocrit Centrifuge.
Max. speed | 12000r/m |
Max. RCF | 14800xg |
Max. capacity | 12 or 24 pieces of capillary |
Control | Microprocessor control, DC brushless Motor |
Time setting range | 0-99 min |
Noise level | <62dB(A) |
Power supply | AC220V 50Hz 2A |
Dimension | 380x320x245mm(LxWxH) |
Weight | 8 or 25 kg |
Computer controlled high speedRefrigerated Centrifugeare useful for centrifugation of temperature sensitive material and find applications in routine and research work in auxiliary laboratories in industry, educational & research institutions, bio technology, medical laboratories, hospitals, blood banks, pharmaceutical laboratories etc. Brushless induction motor with frequency drive & unique automatic rotor identification ensures accurate speed setting for individual rotors. Over current overheating safety cut off circuit is provided for motor protection. Safety lid interlock on the centrifuge ensures that the rotor does not run with cover open while the cover cannot be opened unless rotor comes to complete halt.
A unique safety feature of automatic rotor identification ensures proper speed setting for individual rotors to avoid danger of over speed running. Advanced manufacturing techniques are used for resilient mounting of heavy-duty brushless induction motor resulting in low level of vibration and noise. It is also known asLarge Capacity Refrigerated Centrifuge.
Max. Speed | 21000r/min |
Max. Rcf | 47400xg |
Max. capacity | 6x500ml or 4x750ml |
Control | Pc direct-control |
Speed control accuracy | +/- 50r/min |
The fastest acc/dec time | The acc/dec time can be set freely |
Temperature setting range | -20c~40c |
Temperature control accuracy | +/- 1c |
Refrigeration system | Non-cfc refrigeration system |
Time setting range | 0-23h59min |
Noise level | < 65db(a) |
Power supply | Ac220v 50hz 30a |
Dimension | 710x840x1200(mm) |
Weight | 260kg |
A centrifuge is a piece of equipment that puts an object in rotation around a fixed axis, applying a force perpendicular to the axis. The centrifuge works using the sedimentation principle, where the centripetal acceleration causes denser substances to separate out along the radial direction. Its widely used in field of radicalization immunity, biochemistry, biologic pharmacy, blood separation and purification. This centrifuge also known asCooling Centrifuge, Low Speed Cooling CentrifugeandBench Top Cooling Centrifuge.
Max. speed | 5000r/min |
Max. RCF | 3580xg |
Temperature setting range | -20C~40C |
Power supply | AC220V 50Hz 15A |
Noise level | <65dB(A) |
Time setting range | 0~99min |
Dimension | 590x710x1140mm |
Weight | 180kg |
Rotor
Rotor |
Max speed |
Max RCF |
Capacity |
||||
NO1 Angle rotor |
5000 |
3500 |
6x300ml |
||||
NO2 |
Swing rotor |
4000 |
3040 |
Swing rotor |
4x500ml |
||
4000 |
3040 |
Adapter |
4x250ml |
||||
4000 |
3040 |
4x3x50ml |
|||||
4000 |
3040 |
4x7x20ml |
|||||
4000 |
3040 |
4x9x15ml |
|||||
4000 |
3040 |
4x19x5ml |
|||||
Rectangular Bucket |
4000 |
3040 |
Adapter |
4x4x50ml |
|||
4000 |
3040 |
4x10x15ml |
|||||
4000 |
3040 |
4x20x10ml |
|||||
4000 |
3040 |
4x28x5ml |
|||||
4000 |
3040 |
4x25x1.5ml |
|||||
Bucket |
4000 |
3040 |
4x37x5ml |
||||
4000 |
3040 |
4x24x7ml |
|||||
Rectangular bucket for micro plates |
4000 |
3040 |
4x2x96well |
||||
NO3 |
Micro plate rotor |
4000 |
2200 |
2x2x96well |
|||
NO4 |
Swing rotor |
4000 |
2200 |
4x750ml |
|||
NO5 |
Swing rotor |
4000 |
3580 |
Swing rotor |
6x250ml |
||
4000 |
3580 |
Adapter |
6x7x10ml |
||||
4000 |
3580 |
6x6x15ml(round bottom) |
|||||
4000 |
3580 |
6x4x15ml(conical bottom) |
|||||
4000 |
3580 |
6x50ml |
|||||
4000 |
3580 |
6x10x7ml |
Large Capacity Refrigerated Centrifuge is a multi-use, high-capacity centrifuge. Weiber delivers quality performance in a refrigerated floor standing unit. This is a versatile, compact centrifuge is ideal for high-throughput clinical applications as well as genomics, proteomics, and biochemistry research. It features guaranteed run-to-run reproducibility and absolute sample temperature control and accepts large sample numbers and volumes.
Max. speed | 6000r/min |
Max. RCF | 6680xg |
No 1 angle rotor | 6x500ml (6000r/min RCF: 6680xg) |
No 2 swing rotor | 6x1000ml (4200r/min RCF: 5100xg) |
Speed control accuracy | +/- 50r/min |
Acc/Dec rates | The Acc/Dec time can be set freely |
Temperature setting range | -20C~40C |
Temperature control accuracy | +/-1C |
Refrigeration System | R404a Non-CFC Refrigeration System |
Time setting range | 0-23h59min |
Weight | AC frequency conversion motor |
Heavy duty wood microtome , jung German Type for cutting sections of plastic moulds , wood and other hard specimens. Its features includes: Performance, Versatility and Ergonomics. Designed for medical, biological and industrial applications, the Acm 92307-J Wood Microtome is a universal instrument for a variety of applications in all laboratories where paraffin, tissue, or wood are sectioned. Its sturdy construction gives it qualities that ensure excellent, reproducible sectioning results. Ergonomic design and outstanding safety standards such as a sledge locking device, knife guard and easy access to the sample are the outstanding features of the Acm 92307-J Wood Microtome that ensure trouble free and convenient operation.
Sturdy construction, Section thickness range 1 to 40 m.
Maximum specimen size 90 x 130 mm.
High-precision specimen feed
Robust knife holder
Knife inclination and declination adjustable Specimen orientation
Senior precision rotary microtome is as per Spence A.O. 820 and is the most advanced sectioning equipment for medical colleges, universities, research laboratories, hospitals and educational institutions. The internal mechanism and knife holder rest on a heavy and rigid base to render a shake proof operation. The latest designed protective cover is hinged to the base and swings back so that the interior parts will be completely exposed for convenient cleaning, lubrication & setting etc the feed mechanism is dependent on the vertical movement of the object block. With every complete revolution of the counter balanced drive wheel the feed pawl engages precisely on to the teeth of the ratchet gear which moves towards and advances the object holder thought a cone, inclined plane mechanism in such a precise increments that tissues can be sectioned even in one micron thickness. When the limit of the feed is reached at the end, a safety device automatically disengages the fee mechanism to prevent jamming and damage to the feed screws. The feed indicator is located in the front and feed setting is controlled by a knurled knob at the back of the microtome, to adjust section thickness from 1 50 microns in steps of one microns each. The sturdy knife holder in addition to knife elevating and leveling provides lateral movements for complete use of knife edge.
The angle adjustable up to 300 is indicated on a reference scale. The knife supplied with the microtome is fabricated from high carbon fine grain tool steel which is heat treated for proper temper and tested for micro structures. It is furnished in attractive hammer tone finish and is packed with following accessories in a wooden case along with operating manual.
Section thickness indication | visual display |
Range of section thickness | 1 - 60µm |
Increments
|
from 1-10µm in 1µm steps. from 11-20µm in 2µm steps. from 21-60µm in 5µm steps. |
Specimen Movements | - |
Total Horizontal specimen feed | 25 mm, 60 mm(+-1mm) |
Vertical specimen stroke | XY-Axis: 8°
|
Specimen Orientation | -
|
Convenient specimen holder | Standard Max. 55 x 55 mm |
Specimen Size | - |
Smooth fatigue free Hand wheel | Positive lock at 12 or 6 o'clock position |
Hand wheel Lock | - |
Knife Holder Base | Lateral Displacement |
Displacement | North-south Adjustment |
Adjustments | Clockwise |
Clamping Mechanism | - |
Knife Holder | Microtome Knives of size 100MM - 300MM |
Type of Knife used | Can be used with SPENCERS blade |
Disposable Blade | holder |
Reverse Wheel | Trimming |
Function | - |
Rotary flask shaker serves its Applications in various research laboratories for shaking the liquid in glass flasks. It is a compact bench top model unit. Heavy platform is fitted with rubber discs to hold conical flasks from 50 ml to 1000ml capacity. The shaker is mounted on ball bearing crankshafts to give an orbital circular motion to the flasks. The diameter of the orbit is approximately 2. The entire assembly is mounted on a rental casing which houses a motor coupled by means of V belt with pitch pulleys.
PLATFORM SIZE | MOTOR CAPACITY | HOLDING CAPACITY |
a) 30 x 30 cm | 0.25 H P | 9 flasks / 250 ml |
b) 45 x 45 cm | 0.25 H P
|
16 flasks / 250 ml |
c) 45 x 45 cm | 0.25 H P
|
25 flasks / 100 ml |
d) 45 x 45 cm | 0.25 H P | 9 flasks / 500 ml |
e) 55 x 55 cm | 0.25 H P | 36 flasks / 100 ml |
f) 55 x 55 cm | 0.25 H P | 25 flasks / 250 ml |
g) 55 x 55 cm | 0.25 H P | 16 flasks / 500 ml |
h) 65 x 65 cm | 0.50 H P | 36 flasks / 250 ml |
i) 65 x 65 cm | 0.50 H P | 25 flasks / 500 ml |
j) 105 x 105 cm | 1.0 H P | 81 flasks / 250 ml |
k) 105 x 105 cm | 1.0 H P | 64 flasks / 500 ml |
l) 105 x 105 cm | 1.0 H P | 49 flasks / 1000 ml |
Useful for accelerated mixing of solutions in test tubes, small flasks or centrifugal tubes etc.
Features of Colorimeter:
Detector | Silicon Photo-diode |
Wavelength Range | 400 to 700 nm |
Filter | Interchangeable glass filter 420 nm, 460 nm, 510 nm, 540 nm, 600 nm |
Light Source | LED |
Display | 3 1/2 digits LCD |
Cuvette | Round 10 mm ID,12 mm OD 105mm L |
Wavelength Range | Square 10 mm x 10 mm x 45 mm |
Photometric Range | 400 nm - 800 nm |
Transmittance | 0 ~ 100% T |
Absorbance | 0 ~ 1.999 Abs |
Concentration | 0 ~ 1999 Conc. |
Unlike air jacket CO2 incubator where temperature is maintained by air circulation, the water jacket incubators chamber is surrounded by hot walls, filled with hot water. Water-jacked incubators are the more popular choice. A water jacket will hold the temperature longer than an air-jacket when power is lost. This is helpful in many situations; the incubator will be able to recover more quickly after a power outage and also get back to temperature more quickly after the door has been opened.
It combines precise CO2 control with IR sensors. it feature precise unsurpassed temperature stability, and superior parameter recovery characteristics, with innovative continuous contamination control technology. Carbon Dioxide Incubators are intended for tissue and cell culture applications. The incubator control three essential variables; stable CO2 level, temperature, and relative humidity and creates an ambient environment for cells to thrive.
Interior Volume | 151 Ltrs | 240 Ltrs |
Outer Dimensions (D x W x H) | 762 mm x 637 mm x 909 mm | 820 mm x 780 mm x 944 mm |
Interior Dimensions (D x W x H) | 530 mm x 470 mm x 607 mm | 583 mm x 607 mm x 670 mm |
Shelf Dimension (D x W) | 455 mm x 423 mm | 503 mm x 554 mm |
Standard quantity of shelves | 3 | 3 |
Maximum quantity of shelves | 10 | 12 |
Temperature Setting Range | 5°C to 80°C | 5°C to 80°C |
Temperature Setting Deviation | +/- 0.1°C | +/- 0.1°C |
Temperature Sensor | PT 100 | PT 100 |
Heating System | Water jacketed | |
CO 2 Concentration setting range | 0 - 20 % | 0 - 20 % |
CO 2 Concentration setting Deviation | +/- 0.1% | +/- 0.1% |
Recovery time of CO2 concentration to 5% @ 37oC | Less than 3 minutes | Less than 3 minutes |
CO2 Concentration Sensor | IR sensor | |
Humidity | > 95% | > 95% |
Water Reservoir Volume | 3 Litres | 3 Litres |
Interior Structure | 3 standard shelves With 3 inner glass doors |
3 standard shelves with a glass door |
6 half-size shelves with 6 mini glass doors | ||
Disinfection & time | Moist heat 9 hours @ 900 (disinfection duration: 25 hours) | |
Net Weight | 80 kg | 98 kg |
Rated Power supply | 600w | 735w |
Power Supply | 220V+10% / 50Hz (standard) | |
110V / 60Hz (optional) |
Theair jacket tri gas incubatorsfrom Weiber are designed to provide precise control of O2 and CO2 levels, working temperatures and high humidity conditions within the incubator for a wide variety of hypoxic and hyperoxic applications. These incubators are most commonly employed for growing and maintaining cell cultures and find widespread usage in microbiological studies, cancer research, tissue engineering, neurosciences, in-vitro fertilization and study of drug interaction, toxicity and resistance profiles in various cell lines for drug development and trials. These equipments offer an option of O2 control and CO2 control by using nitrogen gas to displace the ambient air, therefore providing a physiologically similar in-vivo environment and high precision flexible control for robust applications as well as more sophisticated applications with stringent requirements.
Theseair jacket tri gas incubatorsfeature a stainless steel chamber with easy to clean, round corner chamber design and non-corrosive interiors with an antimicrobial coating that offers natural antimicrobial protection upon contact. The equipment adopts a direct heat air jacket heating system for faster heating and rapid temperature recovery. The air jacket also provides insulation from external temperature fluctuations, ensuring greater temperature stability and uniformity. The units are also provided with easy-to-remove, replaceable shelves for segregation of different samples.
Thetri gas incubatorsfrom Weiber come equipped with a well-designed O2/N2 inlet module with dual gas nozzles. They use a multiplex gas system for mixing of multiple gases and maintaining their precise concentration up to an accuracy of +/- 0.1%. These multiple gas control systems use microprocessor based controllers for accurate estimation of O2 levels within the incubator, initiating addition of O2 or N2 as per the requirement. The equipment uses high quality IR CO2 sensors that respond extremely fast to any changes in the gas concentration, thereby ensuring long-term stability of CO2 concentrations. The maintenance free Zirconium oxide sensors provide precise control of O2 concentrations. The built-in air pump allows O2 set-point regulation up to a maximum of 40%. The equipment also comes equipped with an active humidification system for maintaining the adequate humidity levels, therefore providing optimal growth conditions and preventing the cultures from drying out.
Type | Air Jacket temp. control |
Temp. Range | Ambient +3 to 55℃ |
Temperature Deviation | ±0.1°C/±0.5°C |
CO2 Sensor | TC or IR sensor |
CO2 Concentration Range | 0% to 20% |
CO2 Control Accuracy | ±0.1% at 5% |
Relative Humidity Control | 95% ±3% |
Decontamination Phase (all surfaces)† | 90°C/9 hr. |
Interior dimension (DxWxH) | 504x544x681 mm |
Outer dimension (DxWxH) | 656x655x1030 mm |
Net weight | 110 kg |
Power supply | 220V±10% / 50Hz (standard) |
Disinfection | HEPA filter |
Air jacket volume | 43.5 L |
Biochemical Oxygen Demand (BOD) incubators or low temperature incubators enable end users to determine levels of organic matter and nitrogen in wastewater samples. This wastewater must be effectively measured for contaminates, treated and then released back into the environment without posing a threat to the water supply system. Recently, stricter enforcement by government regulatory agencies charged with monitoring air and water quality has forced a greater number of organizations to actively test and treat their wastewater. BOD incubators facilitate the storage of wastewater samples, and can accommodate from 62 565 BOD bottles.
Temperature Control |
|
|
Temperature variation (time) |
± °C |
0.5 |
Temperature deviation (spatial) |
± °C |
0.5 |
Readability/ Set ability |
°C |
0.5 |
Temperature range |
°C |
2°C to 60°C |
Sensor thermocouple |
|
PT 100 |
Controller |
|
PID Controller (HMI+PLC controller optional) |
Display |
|
LCD |
Adjustable alarm limits (visual and acoustic) |
|
Optional |
Safety thermostats |
|
|
Sensor thermocouple |
|
PT 100 |
Automatic setting |
|
Yes |
Adjustable limits |
|
Yes |
Accessories |
|
|
Automatic de-icing system |
|
optional |
Timer (1-999 minutes or hours) |
|
optional |
Real Time Program |
|
optional |
Printer Report Program |
|
optional |
Serial Data Port |
RS232 |
yes |
Inspection window in door |
|
yes |
Shelves |
|
|
Standard/ max |
|
3 |
Dimensions |
mm |
Model Specific |
Accessories |
|
|
Access Port 30 mm |
|
optional |
Inspection window in door with cover |
|
optional |
Castors, lockable |
|
Yes |
Power consumption |
|
|
Nominal voltage |
V |
230, 1~ |
Frequency |
Hz |
50/60 |
Working Size
|
INTERNAL DIMENSIONS (WxHxD) |
CAPACITY |
(a) |
455 x 610 x 410 mm |
4.0 Cu.ft (112 ltrs) |
(b) |
505 x 830 x 415 mm |
6.1 Cu.ft (171 ltrs) |
(c) |
570 x 875 x 550 mm |
10 Cu.ft (280 ltrs) |
(d) |
650 x 900 x 550 mm |
12 Cu.ft (336 ltrs) |
(e) |
700 x 900 x 650 mm |
15 Cu.ft (420 ltrs) |
The LED incubators from WEIBER are dual chambers units that use an LED radiation system to provide optimum and adequate illumination within the incubator, without generating excess heat, facilitating its use for various low temperature applications. They are commonly employed as LED light growth incubators for low temperature testing of products, tissue culture applications, seed germination studies, breeding tests etc.
The LED light incubators from Weiber are employed for a wide range of temperature sensitive applications and find widespread usage in various research laboratories and industrial units. They are available in various standard designs and configurations and can be completely customized as per specific requirements. They are highly versatile equipments that come equipped with a wide range of accessories to suit the requirements of specific applications. They are available as easy to install, portable units that are designed for maximum space efficiency and feature optimum storage area within a compact design. Most of the models also come equipped with removable, easy to clean shelves to allow processing of large batches of different samples.
Temperature Range |
2 to 60°C |
Capacity |
165 L |
Power |
220V, 10 A, 2.2kW, 60 Hz |
Chamber |
Dual chamber |
Illumination |
310 X 580mm & 310 X 580mm |
Door |
Glass door |
Sensor thermocouple |
PT 100 |
Controller |
PID Controller (HMI+PLC controller optional) |
Display |
LCD |
Adjustable alarm limits (visual and acoustic) |
Optional |
Accessories |
|
Automatic de-icing system |
optional |
Timer (1-999 minutes or hours) |
optional |
Real Time Program |
optional |
Printer Report Program |
optional |
Serial Data Port , RS232 |
yes |
Power consumption |
|
Nominal voltage |
230V , single phase |
Frequency |
50/60 Hz |
The dairy incubators from Weiber are well insulated, temperature controlled equipments that use strategically placed heating elements for forced air circulation, ensuring adequate and optimum incubation conditions for dairy products. They provide a highly controlled environment with precise temperature and humidity control and optimum O2 and CO2 concentrations to ensure reliable test results and repeatability of test conditions.
These equipments are available as pre-fabricated walk-in or reach-in incubators that use advanced technologies and an efficient design for highly reliable, economical and efficient operation. They are available in a wide variety of sizes and configurations and can be completely customized according to specific requirements.
Temperature range | 2°C to 90°C |
Temperature Controller | PID controller (HMI+PLC based controller as an option) |
Display | LED/LCD |
Temperature Sensor | PT-100 |
Water reservoir | 18 ltr |
Maximum Permitted load per shelf | 25Kg |
Maximum Permitted total load | 75Kg |
Nominal Power Consumption | 950 W |
Nominal Voltage Consumption | 220-230 Volts, 50 Hz Single Phase |
Frequency | 50 Hz |
1000Lt | 1000mm x 1000mm x 1000mm |
The incubator shakers from Weiber are designed to provide a highly precise and controlled temperature environment for all kinds of laboratory shaking requirements. These equipments are most commonly employed for the shaking of microbial cultures and mixing of reagents and solvents, entomology studies, hybridization washes, staining and de-staining of gels and other laboratory applications requiring incubation and shaking of samples.
The shaking incubators come equipped with a built-in orbital shaker that provides orbital agitation at variable speeds for maintaining adequate aeration for optimum growth of cell cultures. The equipment offers precise control over the agitation speed and the orbit of agitation for uniform and adequate mixing of cultures and solubility studies.
These are commonly available as smaller bench top models that can easily fit into compact laboratory spaces. However we have the ability to customize the size and feature as per individual requirements.
Temperature Control |
|
Temperature variation (time) |
+/-0.5 °C |
Temperature deviation (spatial) |
+/-0.5 °C |
Readability/ Stability |
0.5 °C |
Temperature range |
5°C above ambient to 60°C |
Sensor thermocouple |
Type K |
Controller |
Microprocessor based |
Display |
LED/LCD |
Adjustable alarm limits (visual and acoustic) |
Optional |
Safety thermostats |
|
Temperature variation (time) |
+/-3 °C |
Sensor thermocouple |
Type K |
Automatic setting |
Yes |
Adjustable limits |
Yes |
RPM |
|
Readability/Stability |
1 RPM |
Maximum Stability |
250 RPM |
Accessories |
|
Real Time Program |
optional |
Printer Report Program |
optional |
RS232 |
optional |
Inspection window in door |
optional |
Flask Capacity |
|
Standard/ max |
100ml to 1000ml |
Dimensions |
350mm x 350mm |
Accessories |
|
2 x 24 characters LCD Display |
optional |
Access Port 30 mm |
optional |
Inspection window in door with cover |
optional |
Castors, lockable |
Yes |
Power Consumption |
|
Nominal power |
1250 W |
Nominal voltage |
230, 1~ |
Frequency |
50/60 Hz |
Shaking incubators from Weiber are highly versatile equipments that are designed for all kinds of laboratory shaking and incubator applications, including microbial cell cultures, entomology studies, solubility tests, metabolism studies, stability tests, hematological studies, food processing, quality control and analysis, mixing of reagents and various other laboratory applications.
The equipment features an advanced shaking mechanism, designed for minimum noise, vibration free shaking that provides precise control of the rotation speed for adequate agitation and mixing of the samples. These high quality incubator shakers are suitable for timed as well as continuous, heavy duty applications. They come equipped with various platforms and variable flask and tube support for accommodating various types and sizes of vessels, including flasks, beakers, bottles and test tubes.
These equipments are commonly employed as culture incubator shakers and are used for incubation, fermentation and cross-breeding of bacteria for environmental studies and medical research. They use orbital agitation at variable speeds for maintaining adequate cell aeration for optimum cell cultures.
Temperature range | + 5°C to 70°C |
Temperature accuracy | +/- 1°C |
Display | LED/LCD display |
Platform size | 500mm x 500mm |
shelves | 3 (can be changed as per size) |
Speed range | 80 – 400 RPM |
Temperature controller | Digital P.I.D controller(HMI+PLC based controller as an option) |
Motor | Brushless DC motor |
Power | 230V, 50- 60 Hz |
Safety Device | Over temperature controller |
The bacteriological incubators from WEIBER is designed to maintain optimal temperature conditions for growth of microbiological cultures in a controlled environment.
We specialize in both standard and customized models, specifically designed to meet the challenging demands of various specialized research applications.
Anaerobic culture incubator/chamber is specially designed to be used with oxygen sensitive materials, product containment needs, anaerobic bacteria culture and/or general isolation control. These units allow researchers to easily process, culture and examine samples without exposure to atmospheric oxygen.
The use of a portable incubator when working with any bacterial culture is very helpful. When trying to prevent serious infection or even death, mistakes cannot be made and precision and accuracy are of the utmost importance.
Anaerobic bacteria cultures are performed to identify bacteria that grow only in the absence of oxygen and which may cause human infection. If overlooked or killed by exposure to oxygen, anaerobic infections result in such serious consequences as amputation, organ failure, sepsis, meningitis, and death. Culture is required to correctly identify anaerobic pathogens and institute effective antibiotic treatment.
Anaerobic time of incubator |
Less than 5 m |
Anaerobic time of operate room |
Less than 1 hours |
Anaerobic duration time |
More than 12 hours if there is no micro-mixed air flue in |
Operate room temp range |
RT +3-50OC |
Temperature fluctuation |
≤±0.3 OC |
Temperature uniformity |
:±1 OC |
Power Resource |
220V,50Hz 1P/ 600W |
Incubator size |
25×19×29cm |
Operate room size |
80×65×65cm |
Packing size and G.W |
126×73×138cm 320KG |
TheLow Temperature Incubator, often known asBOD incubatorsare designed to provide excellent temperature uniformity for a wide range of applications requiring low temperature conditions. They are most commonly employed for BOD determinations, fermentation studies, bacterial culturing, plant and insect studies, stability tests and other low temperature applications including desalting of enzyme extracts, serological and complement fixation tests, preservation of vaccines, animal and plant cell culturing etc. and often serve asbacteriological incubators, tissue culture incubators, hospital incubators and scientific incubators.
Acmas Technologies Pvt. Ltd. is a leading manufacturer and exporter of theselow temperature incubatorsin India, offering a wide range of products in both standard as well as customized models. The company offers highlyversatile and economical temperature controlled incubatorsat affordable prices, specifically designed to meet the requirements of the industry. These highly efficientlaboratory incubatorsuse high quality construction materials such as anodized aluminium and epoxy powder coated MS sheets for a highly reliable and sturdy construction. They come equipped with adjustable shelves that can be rearranged with ease, allowing easy placement and segregation of differently sized samples. These double walled insulated cabinets are designed for maximum space efficiency and are available as both floor-mounted as well as bench-top models.
Temperature Controller | Solid State digital Controller/ PID optional |
Temperature Sensor | PT-100 |
Temperature range | 2°C to 90°C /5°C above ambient to 90°C (Standard) |
Display | LED/LCD |
Adjustable alarm limits Water quality | Optional With PID controller only. |
Water Quality./td> | Distilled / Ionized |
Temperature variation Adjustments | 3 (With PID Controllers only) |
Water reservoir | 18 Ltr |
Maximum Permitted load per shelf | 25Kg |
Maximum Permitted total load | 75Kg |
Nominal Power Consumption | 950 W |
Nominal Voltage Consumption | 220-230 Volts, 50 Hz Single Phase |
Frequency | 50 Hz |