My ExportersIndia

For Buyer

For Seller

For Help

Our Products

  1. Transformers 22 Products available
  2. Clamp On Current Transformer 6 Products available
  3. Electronic Gadgets 6 Products available
  4. Relay Protection Test Set 5 Products available
  5. Power Meter 4 Products available
  6. Sensors And Transducers 4 Products available
  7. Power Transformers 4 Products available
  8. CURRENT PROBE 3 Products available
  9. Current Transformer 3 Products available
  10. POS TERMINAL 3 Products available
  11. Isolation Transformer 3 Products available
  12. ENERGY METER CALIBRATOR 2 Products available
  13. ELECTRICAL CALIBRATION 2 Products available
  14. Reference Standard Meter 2 Products available
  15. POWER TRANSDUCER 2 Products available
  16. DIGITAL METER 2 Products available
  17. Power Quality Analyzer 2 Products available
  18. Clamps 2 Products available
  19. AMMETER RECORDER 2 Products available
  20. PGASE ANGLE METER 1 Products available
  21. POWER SOURCE 1 Products available
  22. CT/PT Analyzer 1 Products available
  23. SPLIT CURRENT CORE TRANSFORMER 1 Products available
  24. Handheld Terminal 1 Products available
  25. Transducer 1 Products available
  26. Industrial Chemicals 1 Products available
  27. HANDHELD PDA 1 Products available
  28. Resins 1 Products available
  29. Others Products 58 Products available

POWER TRANSDUCER

Our product range contains a wide range of Three Phase AC Current Voltage Transducer and Single Phase AC Voltage Current Transducer

Three Phase AC Current Voltage Transducer

31,675 / Set Get Latest Price
  • Min. Order (MOQ) 1 Set(s)
  • Dimension 110mm x 75mm x 120mm
  • Installation 35mm DIN sliding-way or M4 screws
  • Working environment Temperature: -10 to +50℃ RH: 20-90%, without condensation
Introduction:change the measured ac currentvoltage to the dc currentvoltage output according to the linear scale, excellent temperature characteristic and good working stability, configuration compactness and briefness features1.three phase current voltage transducer2.ac current voltage transducer3.accuracy class can reach 0.2%4.ac input range can be customized5.dc output range can be customized model descriptionfud-type-input-power supply-outputtype 3i: three phase ac current transducer3u: three phase ac voltage transducerac input a1: 0-1a, a2: 0-5a, a3: 0-10a. V0: 0-70v, v1: 0-120v, v2: 0-250v, v3: 0-300v, v4: 0-450v, v5: 0-500v. Power supply p1: ac110v10%, p2: ac220v15%, p3: ac110v-330v. dc output o1: 0-5v, o2: 1-5v, o3: 0-20ma, o4: 4-20ma, o5: rs485. Example 1: fud-3i-a2-p2-o4fud series three phase ac current transducer input: ac 0-5apower supply: ac220v15%output: dc4-20maexample 2: fud-3u-v2-p2-o4fud series three phase ac voltage transducer input: ac 0-250vpower supply: ac220v15%output: dc4-20maplease check the type, input range, output range and power supply when your order the product. technical indexstandard gbt 13850-1998, iec688:1992accuracy 0.2%, 0.5%consumption 3vaaccuracy drift annual variation < 0.2%insulation voltage ac 2kvmin.1ma (between input- output power)insulation resistance 20m (dc500v)surge voltage 5kv (peak value), 1.250sresponse time 350msinput range ac 0-10a , ac 0-500v(option), 5060hzabsorbed power

Additional Information:

Payment Terms : T/T, Western Union

Delivery Time : 7 Days

View Complete Details

Single Phase AC Voltage Current Transducer

34,390 / Set Get Latest Price
  • Dimension 55mm x 75mm x 120mm
  • Installation 35mm DIN sliding-way or M4 screws
  • Storage conditions Temperature: -40 to +70℃ RH: 20-95%, without condensation
  • Working environment Temperature: -10 to +50℃ RH: 20-90%, without condensation
INTRODUCTION:Changing the measured AC currentvoltage to the DC currentvoltage output according to the linear scale Excellent temperature characteristic and good working stability Configuration compactness and briefness. FEATURES1.Single phase current voltage transducer2.AC current voltage transducer3.Accuracy class can reach 0.2%4.AC input range can be customized5.DC output range can be customized Technical IndexStandard GBT 13850-1998, IEC688:1992Accuracy 0.2%, 0.5%Consumption 3VAAccuracy drift Annual variation < 0.2%Insulation voltage AC 2kVmin.1mA (Between input- output power)Insulation resistance 20M (DC500V)Surge voltage 5KV (Peak value), 1.250sResponse time 350msInput range AC 0-10A , AC 0-500V(Option), 5060HzAbsorbed power
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us