My ExportersIndia

For Buyer

For Seller

For Help

Countronics
gstGST : 09AABHD8394P1ZI Write a Review

Our Products

  1. Limit Controller 11 Products available
  2. Temperature Controller 10 Products available
  3. Data Loggers 7 Products available
  4. Digital Counter 6 Products available
  5. Tachometers 6 Products available
  6. Ammeter 5 Products available
  7. Digital Indicator 5 Products available
  8. Digital Timers 5 Products available
  9. Process Controllers 4 Products available
  10. Instrumentation Equipment 3 Products available
  11. Flow Meters 3 Products available
  12. Measuring Instruments 3 Products available
  13. Electronic Timers 3 Products available
  14. Crane Spare Parts 3 Products available
  15. Conductivity Meter 2 Products available
  16. PH Meter 2 Products available
  17. Clean Room Equipment 2 Products available
  18. Reverse Osmosis Plant Parts 2 Products available
  19. Digital Display 1 Products available
  20. Calibrating Machine 1 Products available
  21. Calibrators 1 Products available
  22. TDS Meters 1 Products available

Limit Controller

Our offered Product range includes PH Controller, Conductivity Controller, Digital Humidity Controller, Model 7215-01 PH and ORP Controller and Model 7210 Digital Humidity Controller.

PH Controller

5,500 / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name Countronics
  • Power Source Electric
  • Feature Accuracy, Stable Performance
  • Country of Origin 220V AC +/- 10% @ 50/60Hz
  • Display 31⁄2 Digit Red, 0.8” character height LED display
  • Accuracy 0.5% ± 1 Digit
  • Availability 700gms
  • Range 0.00 to 14.00 pH
  • Auto Temp 0-100 ̊C using PT100 ext. sensor compensation
  • 2 Relay Outputs Contact rating 5A at 220V AC
  • Size Front facia - 96mm x 96mm x 50mm, Cut Out - 92mm x 92mm
  • Enclosure Plastic ABS

pH Controller, Model 112pH


rn

Features

rn

Accurate pH display with calibration facility on front panel.

rn

Large 0.8 Red 7 Segment Display

rn

Independent 2 Set Point controller with separate relays for each set limit

rn

Auto Temp Compensation using external PT100

rn

Digital calibration for pH-7 and pH-4

rn

rn

Slim enclosure of only 50mm depth


rn

Specifications

rn

Display : 312 Digit Red, 0.8 character height LED display

rn

Range : 0.00 to 14.00 pH

rn

Auto Temp : 0-100 C using PT100 ext. sensor compensation

rn

2 Relay Outputs :Contact rating 5A at 220V AC

rn

Relay Logic : Acid Relay ON for pH> Set Limit + Hysterisis

rn

Base Relay ON for pH < Set Limit - Hysterisis

rn

Calibration : Standard pH-7 : 7.00 1

rn

Slope pH-4 : 4.00 1

rn

Accuracy : 0.5% 1 Digit

rn

Input Impedance: >1012

rn

Supply :220V AC 10% @ 50/60Hz

rn

Size : Front facia - 96mm x 96mm x 50mm

rn

Cut Out - 92mm x 92mm

rn

Enclosure : Plastic ABS

rn

rn

Weight : 700gms

Additional Information:

Payment Terms : T/T

Delivery Time : 15-16 Business Days

View Complete Details

Conductivity Controller

8,500 / piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Feature Durable
  • Number Of Flower Conductivity Controller
  • Country of Origin India
  • Availability 900gms, 1Kg
  • Auto Temp. Comp. 0-100 ̊C using PT100 external sensor
  • Manual Temp. Comp. Settable from front panel from 0-100.0 ̊C
  • Cond/TDS Calibration Digital calibration by factor multiplication from 0.75-1.25
  • Accuracy 0.5% ± 1 Digit
  • Supply 220V AC ±10% @ 50Hz
  • Enclosure Plastic (ABS). Size -96x96x110mmm

Conductivity/TDS Controller Model 160-COND


Features

Auto/Manual temperature compensation selectable

Conductivity and TDS selectable from front panel

Cell Factor selectable for both 1.0 and 0.1

4 Step Range selection 0.1s to 199.9ms for conductivity

Digital calibration for Conductivity/TDS

Auto Temp Compensation using PT100 sensor

Dual set limit with separate relay outputs

Settable hysteresis for both set limits

Bright Red LED display with separate display for set limit-1

Aesthetically designed front panel with membrane switches and ABS cabinet


Specifications

Display : 0.56 Red LED 7 segment Display for Conductivity/TDS

0.56 Red LED 7 segment Display for Set-Limit-1

Ranges : Conductivity: 19.99ms 199.9ms1999 s 0.1 Cell 19.99ms 1.0 Cell199.9s 1999 s19.99s 199.9s

TDS: 0-1999ppm

Resolution : Conductivity: 0.01ms or 0.01s depending on range & Cell factor

TDS: 1ppm

Auto Temp. Comp. : 0-100 C using PT100 external sensor

Manual Temp. Comp. : Settable from front panel from 0-100.0 C

Cond/TDS Calibration : Digital calibration by factor multiplication from 0.75-1.25

Recorder Output : Isolated 4-20mA => 0-2000 (for whatever unit and resolution selected (Maximum termination 250)

Control Output : Two set of NO-P-NC, 5 Amps potential free Relay Contacts.

Relay 1 ON, for Cond/TDS < Set Limit1 Hysterises1

Relay 1 OFF, for Cond/TDS > Set Limit1

Relay 2 OFF, for Cond/TDS < Set Limit2

Relay 2 ON, for Cond/TDS > Set Limit2 + Hysterises2

Accuracy : 0.5% 1 Digit

Supply : 220V AC 10% @ 50Hz

Enclosure : Plastic (ABS). Size -96x96x110mmm

Weight : 900gms

Additional Information:

Payment Terms : T/T

Delivery Time : 15-16 Business Days

View Complete Details

Digital Humidity Controller

6,500 / Piece Get Latest Price
  • Min. Order (MOQ) 1 Piece
  • Brand Name Countronics
  • Condition New
  • Application Industrial
  • Display Range 0-99% for Relative Humidity and 0-99.9 ̊C for Temperature
  • Resolution 1% for Relative Humidity and 0.1 ̊C for Temperature
  • Power Supply 230V AC ± 15% at 50/60Hz
  • P.C. Interface RS-232 output available on extra cost.
  • Mounting Type Panel Type
  • Front Facia 96mm x 96mm
  • Weight 1.2 Kgs.

Digital Humidity/Temperature Controller
Model 7210


Features

Direct, accurate display of Humidity and Temperature

Uses the classical Dry/Wet temperature sensing technique

Sensors are sealed Platinum PT100 type in S.S. immune to atmosphere gases etc.

No need of any look-up table as the embedded software accesses the table from the micro controller memory.

A sturdy sensor body has in-built water reservoir with facility to connect a water-drip to ensure the wick never dries up.

4 Control outputs for Humidifier, De-humidifier, heater and cooler.


Specifications

Display : 2 Digits 0.56 RED 7 Segment LED for Humidity.3 Digits 0.56 RED 7 Segment LED for Temperature

Display Range : 0-99% for Relative Humidity and 0-99.9 C for Temperature

Resolution : 1% for Relative Humidity and 0.1 C for Temperature

Control Range : 0 to 99% for Humidity (over temperature range 0 to 65 C) and 0 to 99.9 C temperature

Accuracy : 2% 1 Least Significant Digit for Humidity.0.2 C 1 Least Significant Digit for Temperature

Settings : By front panel membrane touch switches.

Control Output : Humidifier ON for RH < SET HUMID 1%De-humidifier ON for RH > SET HUMID + 1%Heater ON for Temp. < SET TEMP 0.5%Cooler ON for Temp. > SET TEMP + 0.5 C

Control Relays : 4 sets of NO-P-NC of 5A/220V AC contact rating

Power Supply : 230V AC 15% at 50/60Hz

P.C. Interface : RS-232 output available on extra cost.

Mounting Type : Panel Type

Front Facia : 96mm x 96mm

Weight : 1.2 Kgs.

Additional Information:

Payment Terms : T/T

Delivery Time : 15-16 Business Days

View Complete Details

Model 7215-01 PH And ORP Controller

  • Min. Order (MOQ) 1 Piece
  • Type PH And ORP Controller
  • Display PH LCD / H=1 /2
  • Weight 1.7Lbs. / 0.8kg
  • PH Range 0.00 - 14.00pH
  • PH Resolution 0.01pH
  • PH Control Adjustable Set Point In Range 5.20 - 10.00pH
  • ORP Range +/- 1999mV ORP
  • ORP Resolution +/-1mV ORP
  • ORP Control Adjustable Set Point In Range 200 - 600mV
  • Dimensions 6.2x 6.7x 2.2
  • Power Consumption 115VAC/60Hz / 0.25Amp
  • PH And ORP Outlets 115VAC/60Hz / Maximum 5 Amp. Per Outlet

Features

  • Simultaneous display of pH and ORP
  • Simultaneous control of two pumps/valves
  • 115/220 VAC (Internally selectable)
  • Heavy Duty 10 Amp at 115VAC Relays
  • This unique control system allows both pH and ORP to be controlled and monitored simultaneously. ORP measures the oxidation level in the water typically as a result of water treatment by Chlorine, Bromine, Ozone, Peroxides, Peracetic Acid, etc., and pH allows optimum conditions for the chemistry to be effective.
  • Chemical Automation is recommended by Health Department officials and water quality experts as the only reliable solution to the problems of water chemistry, and in the maintenance of safe and hygienic water. Chemical automation pays for itself very rapidly, through savings in chemicals and maintenance.
View Complete Details

Model 7210 Digital Humidity Controller

  • Min. Order (MOQ) 1 Piece
  • Display Direct From Micro Processor Self Internal Lookup Tables
  • Type Digital Humidity Controller
  • Power Supply 230V AC ± 15%
  • Accuracy 2% For RH & 0.2°C For Temperature
  • Sensor 2 X PT-100
  • Temperature Control Range 0-65°C
  • Humidity Control Range 0-100%
  • Least Count 1% For RH & 0.1°C For Temperature
  • Controls By 10-Turn Helical Potentiometer

Features

  • mP Based Direct Display of Temperature & Humidity.
  • No Need for Lookup Tables.
  • Employs Classical Dry & Wet Bulb RTD(PT-100) Sensors.

 

Control Output

  • TEMPERATURE :2 Relays are provided. One operating 0.5°C above the Set Point for Cooling and the other Operating 0.5°C below the Set Point for Heating.
  • HUMIDITY : 2 Relays are provided. One operating 1% RH below the Set Point for Humidification and the other Operating 1% above the Set Point for De- Humidification
View Complete Details

Dual Limits ORP Controller With Isolated TX. 4-20mA Output

  • Min. Order (MOQ) 1 Piece
  • Accuracy 0.5% ± 1 Digit
  • Display 3½ Digit LED 0.56” Character Height
  • Range -1999mV To +1999mV
  • Calibration Zero Adjust Range ± 30mV
  • Set Limits 0 To 1999mV For Oxidation/Reduction
  • Input Impedance >1012 Ω
  • Tx. Output 4-20mA Isolated For 0-1999mV
  • Supply 110V/220V AC ±10% @ 50/60H
  • Size Front Facia 96mm X 96mm, Cut Out 92mm X 92mm
  • Weight 800 Grams

Features

  • Accurate ORP display with calibration facility on front panel.
  • Independent 2 Set Point controller with separate relays for Oxidation and Reduction
  • Isolated Tx. 4-20mA output for remote monitoring or recording.
  • Consent contact input to enable/disable the control outputs
  • Bright Red LED display for clear viewing

 

Relay Logic

  • Reduction Relay ON for ORP > Set Limit
  • Oxidation Relay ON for ORP < Set Limit
  • Contact rating 5A at 220V AC

 

Front Panel

  • One membrane switch to press and read Oxid. Limit
  • A second membrane switch to read the Reduc. Limit
  • Screw type trimpot to adjust the Calibration Zero
View Complete Details

2 Set Point Digital Conductivity Controller

  • Min. Order (MOQ) 1 Piece
  • Display 3½ Digit LCD
  • Resolution 0.1μs To 0.1ms
  • Accuracy ± 0.5% Of Full Scale
  • Sensor Contact Type With Cell Constant 1.0
  • Temperature Uses PT100 Precision Temperature Sensor
  • Limit Setting 2 Nos. 10 Turn Precision Trimpots On Front Panel
  • Recorder Output 0-2V For The Selected Range
  • Supply 110V AC/220V AC ± 15% Internally Selectable
  • Size Front Fascia - 96mm X 96mm
  • Cabinet Flame Retardant Grade Plastic Enclosure

Features

  • Precision indication of conductivity
  • Automatic Temperature Compensation
  • 4 Step Range selection 0.1s to 199.9ms
  • 2 independent Set Points with High and Low logics for on-line control
  • Front Panel touch type membrane switch to read the limits set
  • Voltage corresponding to Conductivity available for external recorder
  • Cell Adjust on front panel for calibration.

Range

  • a. 199.9s
  • b. 1999s
  • c. 19.99ms
  • d. 199.9ms

The range is selectable from the rear and can be calibrated by Cell Adj at the front for individual range.

Compensation

The Compensation is internally set at 2% per C

NOTE: If PT100 is not available, then fix a simulated resistance of PT100 @ 25C approx. 110. Instrument will not work otherwise.

View Complete Details

100-ORP Dual Limits And Dual Alarms ORP Controller

  • Min. Order (MOQ) 1 Piece
  • Type Orp Controllers
  • Material Plastic
  • Packaging Box
  • Usage Monitoring And Controlling ORP Levels
  • Power Source Electric
  • Display LCD Display
  • Dimensions 6 X 4 X 2 Inches
We are a leading Manufacturer, Exporter, and Supplier offering the 100-ORP Dual Limits and Dual Alarms ORP Controller. Made of durable plastic, this product comes in a box packaging and features an electric power source. The LCD display provides clear readings for monitoring and controlling ORP levels. With dimensions of 6 x 4 x 2 inches, this ORP controller is ideal for various industrial applications requiring precise ORP measurement. Trust our reliable product to ensure accurate results and efficient performance in maintaining water quality.
View Complete Details

Model 121pH PH Controller

  • Min. Order (MOQ) 1 Piece
  • Type PH Controller
  • Display 3½ Digit Red, 0.8” Character Height LED Display
  • Accuracy 0.5% ± 1 Digit
  • Weight 700gms
  • Range 0.00 To 14.00 PH
  • Auto Temp 0-100˚C Using PT100 Ext. Sensor Compensation
  • Calibration Standard PH-7 : 7.00 ± 1, Slope PH-4 : 4.00 ± 1
  • Input Impedance >1012 Ω
  • Supply 220V AC ±10% @ 50/60Hz
  • Size Front Facia – 96mm X 96mm X 40mm, Cut Out – 92mm X 92mm
  • Enclosure Plastic ABS

Features

  • Accurate pH display with calibration facility on front panel.
  • Large 0.8” Red 7 Segment Display
  • Auto Temp Compensation using external PT100
  • Digital calibration for pH-7 and pH-4
  • Slim enclosure of only 40mm depth
View Complete Details

Model 112pH PH Controller

  • Min. Order (MOQ) 1 Piece
  • Type PH Controller
  • Display 3½ Digit Red, 0.8” Character Height LED Display
  • Accuracy 0.5% ± 1 Digit
  • Weight 700gms
  • Range 0.00 To 14.00 PH
  • Auto Temp 0-100˚C Using PT100 Ext. Sensor Compensation
  • Relay Outputs Contact Rating 5A At 220V AC
  • Relay Logic Acid Relay ON For PH> Set Limit + Hysterisis, Base Relay ON For PH < Set Limit – Hysterisis
  • Calibration Standard PH-7 : 7.00 ± 1, Slope PH-4 : 4.00 ± 1
  • Input Impedance >1012 Ω
  • Supply 220V AC ±10% @ 50/60Hz
  • Size Front Facia – 96mm X 96mm X 50mm, Cut Out – 92mm X 92mm
  • Enclosure Plastic ABS

Features

  • Accurate pH display with calibration facility on front panel.
  • Large 0.8” Red 7 Segment Display
  • Auto Temp Compensation using external PT100
  • Independent 2 Set Point controller with separate relays for each set limit
  • Digital calibration for pH-7 and pH-4
  • Slim enclosure of only 50mm depth
View Complete Details

150-ORP Single Set With Band-type Alarm ORP Controller

  • Min. Order (MOQ) 1 Piece
  • Accuracy 0.5% ± 1 Digit
  • Display 3½ Digit LCD
  • Calibration Zero Adjust Range ± 30mV
  • Range -1999mV To +1999mV
  • Set Limits 0 To 1999mV For Oxidation/Reduction
  • Input Impedance >1012 Ω
  • Tx. Output 4-20mA Isolated For 0-1999mV
  • Consent Contact Input From PH Controller. If Open, Cuts Off All Relay Outputs
  • Supply 110V/220V AC ±10% @ 50/60Hz
  • Size Front Facia 96mm X 96mm, Cut Out 92mm X 92mm
  • Enclosure Plastic (ABS) Flame Retardant
  • Weight 800gms

Features

  • Accurate ORP display with calibration facility on front panel
  • One set limit and other window alarm alarm limit with separate relays for Oxidation and alarms
  • Isolated Tx. 4-20mA output for remote monitoring or recording.
  • Consent contact input to enable/disable the control outputs
  • LCD display for low voltage consumption

 

Relay Logic

  • Oxidation Relay ON for ORP < Set Limit
  • Alarm Relay ON for ORP < Set Limit – Alarm and
  • ORP > Set Limit + Alarm
  • Contact rating 5A at 220V AC

 

Front Panel

  • One membrane switch to press and read Oxid. Limit
  • A second membrane switch to read the Alarm. Limit
  • Screw type trimpot to adjust the Calibration Zero
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us