rhp-2d22 dwyer humidity temperature transmitter
rhp-2d22 dwyer humidity temperature transmitter, outside air with sintered filter, 0-10v rh & temp
description
the series rhp temperature and humidity transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or rtd output. The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants.
housing design - outside air with sintered filter
products information
manufacturer:dwyer
part number:rhp-2d22
short description:rhp-2d22 - humidity/temperature transmitter, 3%, outside air with sintered filter, 0-10v rh and temperature output
product series:dwyer rhp series humidity/temperature transmitter
temperature type:humidity/temperature sensors
sensor type:outdoor sensor
accuracy:2%
relative humidity range:0 to 100%
accuracy (temp):+/-0.2c at 25c
connection:conduit connection: 1/2" nps;
electrical connection: removable screw terminal block
output(s):0 - 10 v (rh); 0 - 10 v (temperature)
voltage:15 - 35 vdc or 15 - 29 vac
max temperature:-40 to 140
construction:pbt housing
housing type:rhp series duct mount w/membrane filter
standards/approvals:ce approved
dimensions:3-7/16" x 11.59"
additional products or requirements:related items: a-452, a-453, rhrs
used with:air handling economizers
applications:for outdoor temperature and relative humidity reference, pool room humidity monitoring
Additional Information:
Payment Terms : L/C, D/A, D/P
Delivery Time : 5-6 Week
rhp-3s22 dwyer humidity temperature transmitter
rhp-3s22 - dwyer humidity/temperature transmitter, outside air with sintered filter, 0-10v rh & temp
description
the series rhp temperature and humidity transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or rtd output. The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants.
housing design - outside air with sintered filter
products information
manufacturer:dwyer
part number:rhp-3s22
short description:rhp-3s22 - humidity/temperature transmitter, 3%, outside air with sintered filter, 0-10v rh and temperature output
product series:dwyer rhp series humidity/temperature transmitter
temperature type:humidity/temperature sensors
sensor type:outdoor sensor
accuracy:3%
relative humidity range:0 to 100%
accuracy (temp):+/-0.2c at 25c
connection:conduit connection: 1/2" nps;
electrical connection: removable screw terminal block
output(s):0 - 10 v (rh); 0 - 10 v (temperature)
voltage:15 - 35 vdc or 15 - 29 vac
max temperature:-40 to 140
construction:polycarbonate housing
housing type:rhp series osa w/sintered filter
standards/approvals:ce approved
dimensions:5-1/8" x 2-1/4" x 6-25/32"
additional products or requirements:related items: a-452, a-453, rhrs
used with:air handling economizers
applications:for outdoor temperature and relative humidity reference, pool room humidity monitoring
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 5-6 Week
RHP-3O22 DWYER Humidity Temperature Transmitter
RHP-3O22 - DWYER HUMIDITY/TEMPERATURE TRANSMITTER, 3%, OSA (OUTSIDE AIR)
DESCRIPTION
The Series RHP Temperature and Humidity Transmitter Combine The Voltage or Current Humidity Transmitter Output With a Passive Temperature Thermistor or RTD output. The Polymer Capacitance Humidity Sensor is Not Affected By Condensation, Fog, High Humidity, Or Contaminants.
Housing Design - Outside Air
PRODUCTS INFORMATION
MANUFACTURER:Dwyer
PART NUMBER:RHP-3O22
SHORT DESCRIPTION:RHP-3O22 - Humidity/Temperature Transmitter, 3%, OSA (Outside Air), 0-10V RH and 0-10V Temperature Output
PRODUCT SERIES:Dwyer RHP Series Humidity/Temperature Transmitter
TEMPERATURE TYPE:Humidity/Temperature Sensors
ACCURACY:3%
RELATIVE HUMIDITY RANGE:0 - 100%
ACCURACY (TEMP):+/-0.2C at 25C
CONNECTION:Electrical Connection: Removable Screw Terminal Block, Conduit Connection: 1/2"
OUTPUT(S):0 - 10 V (RH), 0 - 10 V (Temperature)
VOLTAGE:15 - 35 VDC or 15 - 29 VAC
MAX TEMPERATURE:-40 to 140F
CONSTRUCTION:Polycarbonate
MOUNTING OPTIONS:OSA (Outside Air)
HOUSING TYPE:RHP Series OSA (Outside Air)
STANDARDS/APPROVALS:CE Approved
DIMENSIONS:5-1/8" x 2-15/64" x 6-25/32"
ADDITIONAL PRODUCTS OR REQUIREMENTS:Related Items: A-452, A-453, RHRS
APPLICATIONS:For Air Economizers, Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 5-6 Week
RHP-3D11 DWYER Humidity Temperature Transmitter
The Series RHP Temperature and Humidity Transmitter combine the Voltage or current Humidity Transmitter output with a passive temperature thermistor or RTD output. The polymer capacitance humidity sensor is not affected by condensation, fog, high humidity, or contaminants. The humidity sensors are available with 2% or 3% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display. Application Note: For duct mount installations, the sintered filter option should be ordered for applications where the Humidity Transmitter is mounted in the supply air duct after the fan and cooling coils.
Availability: Item ships in about Ships in 4-6 weeks
Product Highlights
Duct mount
3% RH/temperature transmitter
4-20 mA RH output
4-20 mA temperature output
OTHER CONFIGURATIONS AVAILABLE
PRODUCT SPECIFICATIONS
Relative Humidity Range: 0 to 100% RH.
Temperature Range: -40 to 140F (-40 to 60C).
Accuracy, RH: RHP-2XXX 2% 10-90% RH @ 25C; RHP-3XXX 3% 20-80% RH @ 25C; RHP-5XXX 5% 20-80% RH @ 25C.
Accuracy, Thermistor Temp Sensor: 0.2C @ 25C (0.36F @ 77F).
Accuracy, RTD Temp Sensor: DIN Class B; 0.3C @ 0C (0.54F @ 32F).
Hysteresis: 1%.
Repeatability: 0.1% typical.
Temperature Limits: -40 to 140F (-40 to 60C).
Storage Temperature: -40 to 176F (-40 to 80C).
Compensated Temperature Range: -4 to 140F (-20 to 60C).
4-20 mA Loop Powered Models: Power Requirements: 10-35 VDC. Output Signal: 4-20 mA.
0-5/10V Output Models: Power Requirements: 15-35 VDC or 15-29 VAC. Output Signal: 0-10V @ 5 mA max.
Response Time: 15 seconds.
Electrical Connections: Removable screw terminal block.
Conduit Connection: Duct Mount: 1/2" NPS; OSA: 1/2" (22.3 mm).
Drift:
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 5-6 Week
Series RHP Humidity/Temperature Transmitter
Passive Temperature Outputs, Sintered Filter Options
The Series RHP Temperature and Humidity Transmitter combine the voltage or current humidity transmitter output with a passive temperature thermistor or RTD output. Featuring polymer capacitance humidity sensors, models are available in 2%, 3% or 5% accuracies. Duct mounted transmitters are available with an optional two-line alpha numeric LCD display.
Product Applications
Air Economizers, Outdoor Temperature and Relative Humidity Reference, Pool Room Humidity Monitoring
Model Description
RHP-2D10:Duct mount 2% RH transmitter with 4-20 mA RH output.
RHP-2D11:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output.
RHP-2D11-LCD:Duct mount 2% RH/temperature transmitter, 4-20 mA RH output and 4-20 mA temperature output, with LCD.
RHP-2D1A:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K Curve A passive temperature output.
RHP-2D1B:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K @ 25C thermistor temperature output.
RHP-2D1D:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 100 Ohm RTD Curve D passive temperature output.
RHP-2D1E:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 1K Ohm RTD DIN 385 temperature output.
RHP-2D1F:Duct mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output.
RHP-2D20:Duct mount 2% RH transmitter with 0-10 VDC RH output.
RHP-2D22:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 0-10 VDC temperature output.
RHP-2D22-LCD:Duct mount 2% RH/temperature transmitter, 0-10 VDC RH output and 0-10 VDC temperature output, with LCD.
RHP-2D2A:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K Curve A passive temperature output.
RHP-2D2B:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 10K @ 25C thermistor temperature output.
RHP-2D2D:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 100 Ohm RTD Curve D passive temperature output.
RHP-2D2E:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 1K Ohm RTD DIN 385 temperature output.
RHP-2D2F:Duct mount 2% RH/temperature transmitter with 0-10 VDC RH output and 20K NTC thermistor temperature output.
RHP-2M11:Sintered filter duct mount humidity/temperature transmitter with 2% sensor, 4 to 20 mA output for humidity and temperature.
RHP-2M22:Sintered filter duct mount humidity/temperature transmitter with 2% sensor, 0 to 10 V output for humidity and temperature.
RHP-2O10:OSA 2% RH transmitter with 4-20 mA RH output.
RHP-2O11:OSA 2% RH/temperature transmitter with 4-20 mA RH output and 4-20 mA temperature output.
RHP-2O1A:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type III NTC thermistor temperature output.
RHP-2O1B:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 10K type II NTC thermistor temperature output.
RHP-2O1D:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt100 RTD temperature output.
RHP-2O1E:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and Pt1000 RTD temperature output.
RHP-2O1F:OSA mount 2% RH/temperature transmitter with 4-20 mA RH output and 20K NTC thermistor temperature output.
RHP-2O20:OSA 2% RH transmitter with 0-10 VDC RH output.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 5-6 Week
Medical Hepa Filters
We Manufacture And Supply a Wide Range of HEPA Filters Which Has High Filtration Efficiency. These are Manufactured by Hemmed edges of Aluminum Separators in order to Provide Rigidity & uniform Air Flow. We do Quality Analysis and Testing of these Industrial HEPA Filters before we Handover this to our Valuable Clients. We have Specialized Team of Experts Who Do Quality Checking Under Certain Parameters that Meets International Standards.
Salient Features Are As Follows:
Aluminum, S.S and G.I is Used to Make The Body of HEPA filter
Used in Biomedical Purpose,
Vacuum Cleaners,
Nuclear Industry,
Aerospace,
Nuclear Power,
Pharmaceutical Processing,
Health Care,
Hospitals,
Nuclear Fuels, and Electronic Micro Circuitry (Computer Chips).
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 7-10 Day