Our Products
Series MAFS Metal Averaging Flow Sensor
Blade Profile Provides Enhanced Performance and Minimal Flow Disruption
The SERIES MAFS Metal Averaging Flow Sensor is ideal for use with Dwyer Instruments, Inc. precision air velocity gages, transmitters and switches. The Series MAFS uses evenly distributed total and static pressure measuring points to deliver an accurate measurement of velocity pressure in a duct.
Product Applications
VAV air flow measurement
Fume hood exhaust flow verification
HVAC retrofit air flow measurement
ModelDescription
MAFS-04Averaging air flow sensor, 4" probe
MAFS-06Averaging air flow sensor, 6" probe
MAFS-08Averaging air flow sensor, 8" probe
MAFS-10Averaging air flow sensor, 10" probe
MAFS-1000MMAveraging air flow sensor, 1000mm probe
MAFS-100MMAveraging air flow sensor, 100mm probe
MAFS-12Averaging air flow sensor, 12" probe
MAFS-125MMAveraging air flow sensor, 125mm probe
MAFS-14Averaging air flow sensor, 14" probe
MAFS-1500MMAveraging air flow sensor, 1500mm probe
MAFS-16Averaging air flow sensor, 16" probe
MAFS-1600MMAveraging air flow sensor, 1600mm probe
MAFS-160MMAveraging air flow sensor, 160mm probe
MAFS-18Averaging air flow sensor, 18" probe
MAFS-20Averaging air flow sensor, 20" probe
MAFS-2000MMAveraging air flow sensor, 2000mm probe
AFS-200MMAveraging air flow sensor, 200mm probe
AFS-22Averaging air flow sensor, 22" probe
MAFS-24Averaging air flow sensor, 24" probe
MAFS-250MMAveraging air flow sensor, 250mm probe
MAFS-26Averaging air flow sensor, 26" probe
MAFS-28Averaging air flow sensor, 28" probe
MAFS-30Averaging air flow sensor, 30" probe
MAFS-300MMAveraging air flow sensor, 300mm probe
MAFS-315MMAveraging air flow sensor, 315mm probe
MAFS-32Averaging air flow sensor, 32" probe
MAFS-34Averaging air flow sensor, 34" probe
MAFS-36Averaging air flow sensor, 36" probe
MAFS-38Averaging air flow sensor, 38" probe
MAFS-40Averaging air flow sensor, 40" probe
MAFS-400MMAveraging air flow sensor, 400mm probe
MAFS-42Averaging air flow sensor, 42" probe
MAFS-44Averaging air flow sensor, 44" probe
MAFS-450MMAveraging air flow sensor, 450mm probe
Specifications
Service:Clean air.
Wetted Materials:Aluminum AA6063.
Accuracy:400 to 9000 FPM (45.7 m/s): 2% FS; 3% FS for 6" and 48" length models.
K-Factor:0.81, 0.80 for 6" (160 mm) and 48" (1200 mm) lengths, 4" (100 mm) length=0.82.
Max. Temperature:400F (204C); Gasket: -31 to 230F (-35 to 110C).
Minimum Design Flow:400 fpm (2 m/s).
Maximum Design Flow:12, 000 fpm (60.91 m/s).
Process Connections:Dual barb for 3/16" or 1/4" ID tubing.
Straight Run Requirements:5 diameters or longest side dimensions.
Agency Approvals:Meets the technical requirements of EU Directive 2011/65/EU (RoHS II).
Features
Blade design limits disruption of air stream
Lightweight aluminum construction
Flange mount for rectangular or square ducts
Related Products
Series DH Digihelic Differential Pressure Controller
Series MS Magnesense Differential Pressure Transmitter
Series DHII Digihelic Differential Pressure Controller
Series DH3 Digihelic Differential Pressure Controller
Series MS2 Magnesense II Differential Pressure Transmitter
Feature : Easy To Install, Proper Working, Superior Finish
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Outdoor Temperature Sensors (Series TE-OND/TE-RND/TE-OSA)
Series TE-OND/TE-RND/TE-OSA Outdoor Temperature Sensors
Protection Against Radiated Heat, Weatherproof Housing
The Series TE-OND/TE-RND/TE-OSA Outdoor Air Temperature Sensors are offered in two different configurations to increase measurement accuracy by reducing radiated heat effects. For applications where the north side of the building is accessible, the TE-OND/TE-OSA can be used to protect against low levels of radiated heat. If the sensor must be mounted in direct sunlight or a more precise measurement is required, our six plate radiation shield mounts over the temperature probe. The TE-RND radiation shield models can be surface or pipe mounted. All models include removeable terminal blocks to simplify wiring.
ModelDescription
TE-OND-AOutside air temperature sensor, 10K Type III thermistor
TE-OND-BOutside air temperature sensor, 10K Type II thermistor
TE-OND-COutside air temperature sensor, 3K thermistor
TE-OND-DOutside air temperature sensor, Pt100 RTD sensor
TE-OND-EOutside air temperature sensor, Pt1000 RTD sensor
TE-OND-FOutside air temperature sensor, 20K thermistor
TE-OND-QOutside air temperature sensor, 10K Type III thermistor with 11K shunt
TE-OSA-AOutside air temperature sensor, 10K type III thermistor
TE-OSA-BOutside air temperature sensor, 10K type II thermistor
TE-OSA-COutside air temperature sensor, 3K thermistor
TE-OSA-DOutside air temperature sensor, PT100 RTD
TE-OSA-EOutside air temperature sensor, PT1000 RTD
TE-OSA-FOutside air temperature sensor, 20K thermistor
TE-OSA-QOutside air temperature sensor, 10K type III thermistor with 11K shunt
TE-RND-AOutside air temperature sensor with radiation sheild, 10K Type III thermistor
TE-RND-BOutside air temperature sensor with radiation shield, 10K Type II thermistor
TE-RND-COutside air temperature sensor with radiation shield, 3K thermistor
TE-RND-DOutside air temperature sensor with radiation shield, Pt100 RTD sensor
TE-RND-EOutside air temperature sensor with radiation shield, Pt1000 RTD sensor
TE-RND-FOutside air temperature sensor with radiation shield, 20K thermistor
TE-RND-QOutside air temperature sensor with radiation shield, 10K Type III thermistor with 11K shunt
Specifications
Accuracy:Thermistor temperature sensor: 0.22C @ 25C (0.4F @ 77F);
RTD temperature sensor: DIN class A: 0.15C @ 0C (0.28F @ 32F).
Temperature Limits:Operating: -40 to 302F (-40 to 150C).
Sensor Curves:See Resistance vs. Temperature Table.
Housing Material:Polycarbonate.
Enclosure Rating:TE-OND/TE-RND: NEMA 4X (IP65); TE-OSA: NEMA 3R (IP54).
Weight:0.65 lb (295 g).
Ambient temperature : Operating: -40 To 302F (-40 To 150C).
Certification : YAS
Application : Building Is Accessible
Warranty : 1yrs
Color : Light White
Type : Outdoor Temperature Sensors
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Occupancy Sensor
The Model OSC-200 Omnidirectional Occupancy Sensor automatically controls a HVAC ventilation system. A spherical Fresnel lens provides a 360 detection zone with the use of infrared technology. The integrated dual delay processor saves energy by eliminating false activation due to short-term occupancies. The Model OSC-200 is designed to be ceiling mounted, and is pre-wired for ease of installation.
Features:
Delay processor suppresses switch activation during momentary occupancy
Applications:
Lighting control
Building energy conservation
Install Base Unit:
Determine the location of the sensor according to the detection pattern shown in Figure 1a.
Remove the cover screw to open the sensor housing as shown in Figure 1b.
Remove the circuit board by bending the tab outward (Figure 1b.)
Screw the base of the sensor housing to the ceiling through the knockout holes
Wiring:
Model OSC-200 is pre-wired for ease of use with 22AWG colored wires. Connect the wires as showin in figure 2
Walk Test:
Before beginning test, make certain that the On and Off Delay jumpers (located on the circuit board) are connected in the A positions as shown in Figure 3. If they are not, follow the procedure under the section titled On/Off Delay Settings to rearrange the jumpers to location A. Replace the sensor housing and tighten screw.
Storage And Cleaning:
The sensor lens is the most delicate part of the Occupancy Sensor. The lens should be kept clean at all times, care should be taken when cleaning the lens using only a soft cloth or cotton swab with water or medical alcohol. Allow the lens to fully dry before using the sensor. The sensor should be installed or stored in an area of room temperature between -4 and 140F (-20 to 60C).
Maintenance:
After final installation of the unit, no routine maintenance is required. The Model OSC-200 is not field serviceable and should be returned if repair is needed (field repair should not be attempted and may void warranty). Be sure to include a brief description of the problem plus any relevant application notes. Contact customer service to receive a return goods authorization number before shipping.
Warranty : 1year
Application : Lighting Control
Brand Name : DWYER USA
Condition : New
Type : Occupancy Sensors
Detectable Speed:0.33 to 9.8 ft/sec (0.1 to 3.0 m/sec). : Control Output Rating:SPDT, 0.2A at 30 VDC.
Ambient Operating Temperature:-4 to 140F (-20 to 60C). : Power Consumption:Standby: 5 mA, Operating: 18 mA.
Mounting Height:7.9 to 13.8 ft (2.4 to 4.2 m). : Power Requirements:22 to 26 VAC/DC.
Infrared Sensor:Dual element. : Range:34.4 ft (10.5 m) Diameter at 13.8 ft (4.2 m) mount height.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Series AFG Averaging Flow Grid
cost effective air flow station for ducts up to 60"
the series afg flow grid is an outstanding simple yet accurate cost effective alternative to other duct mounted pressure sensors. Once installed and connected to a suitable measuring instrument, the device will provide years of trouble free monitoring of both air and gas flow. Installing the afg flow grid is quick and easy, the afg is supplied in kit form to allow both workshop and on-site installation into a wide range of square and circular ducts up to approximately 60".
the afg flow grid is a fundamental pressure sensing device designed to transmit a continuous differential pressure signal. When this output is connected to a suitable measuring instrument (i.e., manometer, pressure transducer, etc.), it may be used to determine air velocity and volume flow rate.
how the afg flow grid works
the afg flow grid consists of two tubes mounted diagonally across a square or rectangular duct, or diametrically across a round duct. The tubes are drilled with a series of equi-spaced holes.
the holes in one tube face directly upstream and sense total pressure, while the pairs of holes in the second tube also face forward but at an included angle of 79 degrees, sensing static pressure. The total and (sub) static pressures are averaged along the length of each tube and provide pressure signals at connectors outside the duct wall. The pressure differentials across these connectors constitute the output signal.
product applications
to display differential pressure, velocity or volume flow using a micro manometer, gage, or transmitter
to give a warning of over or under flow rate using a pressure switch
to control air supply in a system by connecting the grid to a pressure transmitter with an electrical output which can be used to feed into a control system
to display differential pressure on a simple fluid manometer to give visual indication of changes in volume flow rate in the duct
modeldescription
afg-1averaging flow grid, 5/16" (8 mm) tube diameter, 27" (688 mm) tube length.
afg-2averaging flow grid, 5/8" (16 mm) tube diameter, 59-4/5" (1518 mm) tube length.
specifications
service:monitor air or compatible gas flow.
wetted materials:304 ss, pvc, polyurethane, acetyl plastics, and neoprene rubber.
accuracy:5%.
maximum temperature:176f (80c).
velocity range:295.2 ft/min to 5904 ft/min (1.5 to 30 m/sec).
diameter of tubes:5/16" (8 mm) or 5/8" (16 mm).
maximum duct diagonal:60.4" (153.4 cm).
maximum duct diameter:59.4" (150.9 cm).
process connections:5/16" barbed.
weight:afg-1: 1 lb (454 g); afg-2: 3 lb (1361 g).
features
kit complete with 2 probes and installation hardware
trimmable length for any duct size up to 60"
alternative to costly air flow stations
Material : And Neoprene Rubber.
Feature : Easy To Install, High Quality, Quality Approved
Packaging Type : Carton
Type : Series AFG Averaging Flow Grid
Finishing : Polished
Use : Monitor Air Or Compatible Gas Flow.
Color : Silver
Condition : New
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Wall Mount Temperature Sensor (Series TE-E/N)
Wall Mount Temperature Sensor
Series TE-E/N Wall Mount Temperature Sensor
Discrete Wall Mount Housing
The Series TE-E/N Wall Mount Temperature Sensor provides a low cost temperature input for any building management system. With large vents in the housing for proper air flow, the sensor accurately measures the ambient temperature in hotel rooms or office buildings. Multiple mounting holes on the wall plate allow for mounting to numerous surfaces.
Product Applications
Room temperature monitoring
Building automation
ModelDescription
TE-END-AEU Wall Mount Temperature Sensor, 10K Ohm Type III Sensor
TE-END-B EU Wall Mount Temperature Sensor, 10K Ohm Type II Sensor
TE-END-C EU Wall Mount Temperature Sensor, 3K Ohm Sensor
TE-END-DEU Wall Mount Temperature Sensor, Pt100 Ohm RTD Sensor
TE-END-E EU Wall Mount Temperature Sensor, PT1K Ohm RTD Sensor
TE-END-F EU Wall Mount Temperature Sensor, 20K Ohm Sensor
TE-NND-ANA Wall Mount Temperature Sensor, 10K Ohm Type III Sensor
TE-NND-BNA Wall Mount Temperature Sensor, 10K Ohm Type II Sensor
TE-NND-CNA Wall Mount Temperature Sensor, 3K Ohm Sensor
TE-NND-DNA Wall Mount Temperature Sensor, Pt100 Ohm RTD Sensor
TE-NND-ENA Wall Mount Temperature Sensor, PT1K Ohm RTD Sensor
TE-NND-FNA Wall Mount Temperature Sensor, 20K Ohm Sensor
TE-NND-QNA Wall Mount Temperature Sensor, 10K Ohm Type III with 11K Ohm shunt
Specifications
Accuracy:Thermistor temp sensor: 0.22C @ 25C (0.4F @ 77F); RTD temp sensor: DIN class B; 0.3C @ 0C (.54F @ 32F).
Temperature Limits:-40 to 140F (-40 to 60C).
Housing Material:ABS plastic.
Weight:0.3 lb (136 g).
Features
North American or European housing aesthetic options
Uniform look matches other Dwyer wall mount devices
Universal mounting plate meets various installation requirements
Related Products
Series RHP-W Wall Mount Humidity/Temperature/Dew Point Transmitter
Series RHP-W Wall Mount Humidity/Temperature/Dew Point Transmitter
Series CDT Carbon Dioxide/Temperature Transmitter
Series CDT Carbon Dioxide/Temperature Transmitter
Series CDTR Carbon Dioxide/RH/Temperature Transmitter
Series CDTR Carbon Dioxide/RH/Temperature Transmitter
Type : Wall Mount Temperature Sensor
Warranty : 1yrs
Ambient temperature : -40 To 140F (-40 To 60C).
Application : Room Temperature Monitoring
Certification : YES
Color : Grey
Housing: Material:ABS plastic. : Weight:0.3 lb (136 g).
Brand:Dwyer USA : Temperature Range:-40 to 140 Degree F (-40 to 60 Degree C)
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
series pafs-1000 averaging flow sensor
ideal for sensing fan flow rates
the series pafs-1000 averaging flow sensor is ideal for sensing differential pressure in the inlet section of variable air volume terminal units and fan terminal units. Units can also be used to sense differential pressure at other locations in the main or branch duct systems.
the "h" port senses total pressure and the "l" port senses static pressure. The difference between these signals is the differential, or velocity pressure. For models pafs-1002 to pafs-1005, up to four sensing points and lengths of 3-5/32" to 9-29/32" (8.02 to 25.26 cm) to accommodate box size diameters of 4" to 16" (10.16 to 40.64 cm) are available. For models pafs-1006 to pafs -1011, up to 10 sensing points and lengths from 12-1/2" to 23-29/32" (31.75 to 60.72 cm) are available to accommodate appropriately sized duct dimensions.
product applications
zone control in hvac systems
modeldescription
pafs-1002averaging flow sensor, 3-5/32" (8.02 cm) insertion length.
pafs-1003averaging flow sensor, 5-13/32" (13.73 cm) insertion length.
pafs-1004averaging flow sensor, 7-21/32" (19.55 cm) insertion length.
pafs-1005averaging flow sensor, 9-29/32" (25.26 cm) insertion length.
pafs-1006averaging flow sensor, 12-1/2" (31.75 cm) insertion length.
pafs-1007averaging flow sensor, 14-3/4" (37.47 cm) insertion length.
pafs-1008averaging flow sensor, 17-1/8" (43.50 cm) insertion length.
pafs-1009averaging flow sensor, 19-13/32" (49.29 cm) insertion length.
pafs-1010averaging flow sensor, 21-21/32" (55.01 cm) insertion length.
pafs-1011averaging flow sensor, 23-29/32" (60.72 cm) insertion length.
specifications
service:air and compatible gases.
wetted materials:abs/polycarbonate (ul94-5v).
temperature limits:operating: 40 to 120f (4 to 49c); storage: -40 to 140f (-40 to 60c).
process connection:1/4" (6 mm) id, 3/8" (10 mm) od tubing.
mounting orientation:integral flange with gasket.
weight:1 oz (28 g).
agency approvals:meets the technical requirements of eu directive 2011/65/eu (rohs ii).
Certification : yas
Operating Temperature : Operating: 40 to 120F (4 to 49C); Storage: -40 to 140F (-40 to 60C).
Name : Series PAFS-1000 Averaging Flow Sensor
Warranty : 1yr
Type : Series PAFS-1000 Averaging Flow Sensor
Feature : Easy To Install, Proper Working
Application : Air and compatible gases.
Brand Name : DWYER USA
Usage : Air and compatible gases.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Insertion Electromagnetic Flow Sensor
Series EFS2 Insertion Electromagnetic Flow Sensor
No Moving Parts, Durable, Easy Installation & Maintenance, 1 to 12" Pipe (25 to 305 mm)
The SERIES EFS2 Insertion Electromagnetic Flow Sensor is designed for pipe sizes from 1 to 12" and comes in three different materials (stainless steel, brass and PVC). There are a variety of custom fittings to choose from to ensure accurate fitting in the pipe. The Series EFS2 is useful for any applications where moving parts would be a problem, such as dirty liquids. It can handle applications where there are rapid changes in viscosity and flow. Other applications include small pipes and chemical metering pumps.
PRINCIPLE OF OPERATION:The EFS2 is a liquid flow meter that uses the conductivity of fluids to measure flow rate. Liquid flow through its magnetic field produces a voltage that is measured and translated into an output signal. It has a pulse frequency output which can be used with the Series RTI to indicate flow rate and total, as well as the Series BAT signal converter which provides an analog signal.
ACCESSORIES :Series BAT, Blind Analog Transmitter, converts pulse output to 4 to 20 mA analog output. Unit is loop powered, fits on the enclosure of the meter, and is fields spannable.Series RTI2, Rate Total Indicator, converts pulse output to 4 to 20 mA analog output with local flow rate and totalization display. Unit is loop powered, can fit on the enclosure of the meter, and provides a high/low flow alarm.Series PWD, Pulse Divider, for use with pacing electronic metering pumps. Unit divides the input frequency to any number from 1 to 9999 with the use of rotary switches to suit a number of metering pump inputs.
Product Applications, Contaminated liquid flow monitoring, Flow of conductive liquidsWater & wastewater treatment
Industrial systems
Irrigation applications
Telemetry applications
Specifications
Service:Compatible clean or dirty non-coating, conductive liquids.Range:0.28 to 20 ft/s (0.08 to 6.09 m/s).Wetted Materials:Sensor: 316 SS, brass or PVC;Electrodes: Hastelloy, metal;
Electrode Cap: PVDF;O-ring: EPDM (fluoroelastomer optional).
Accuracy:1% FS.
Temperature Limits:Process: Brass/SS: 32 to 200F (0 to 93C);
PVC: 32 to 130F (0 to 55C);
Ambient: 0 to 160F (-17 to 72C).
Pressure Limits:Brass/SS: 200 psi (13.8 bar);
PVC: 150 psi (10 bar).
Process Connection:See Series EFF.
Output:Current sinking, square wave pulse, opto-isolated, 550 Hz @ 20 ft/s.
Power Requirements:12 to 25 VDC @ 250 mA; (12 to 25 VDC @ 40 mA (max. 250 mA) - LOP option).
Electrical Connection:Terminal block.
Conductivity:20 microSiemens/cm.
Enclosure Material:Housing: Die-cast powder-coated aluminum.
Enclosure Rating:NEMA 4X (IP66).
Weight:3 lb (1361 g)
Type : Series EFS2 Insertion Electromagnetic Flow Sensor
Material : Brass Or PVC
Body Material : Sensor: 316 SS, Brass Or PVC; Electrodes: Hastelloy, Metal; Electrode Cap: PVDF; O-ring: EPDM, Condition : New, Application : Conductive Liquids., Color : Blue, Lining Material : Sensor: 316 SS, Brass Or PVC; Electrodes: Hastelloy, Metal; Electrode Cap: PVDF; O-ring: EPDM, Usage : Compatible Clean Or Dirty Non-coating, Conductive Liquids.
Power : 12 To 25 VDC @ 250 MA; (12 To 25 VDC @ 40 MA (max. 250 MA) - LOP Option).
Brand Name : DWYER USA, Warranty : 1year
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Magnetic Inductive Flow Sensor (Series MFS)
series mfs magnetic inductive flow sensor
no moving parts, frequency and 4 to 20 ma output, maintenance-free
the series mfs magnetic inductive flow sensor is a compact, low cost alternative to paddle wheel sensors. Unlike sensors with moving parts, the mfs can be applied in applications dealing with contaminated media. This series provides a reliable measuring technique, an obstruction free pipe cross-section, as well as a quick response time, making this series ideal for interference free operation. Any change in temperature, density, viscosity, concentration or electrical conductivity of the liquid, does not affect the output signal of this magnetic inductive flow sensor. This, in addition to its long-life cycle, makes this series perfect for accurate reversible gauging of volume flow of conductive liquids in closed piping.
principles of operation
the measuring pipe is in a magnetic field. If an electrically conductive medium with a certain flow passes through the pipe, it passes at a right-angle to the magnetic field, creating a voltage which is proportional to the average flow velocity and picked up by two electrodes within the mfs. A frequency output signal is obtained that is proportional to the flow (analog output option available).
product applications
contaminated liquid flow monitoring
flow of conductive liquidswater & wastewater treatment
industrial systems
irrigation applications
specifications
service:water and other conductive liquids.
wetted materials:electrodes: 316 ti ss; process connections: 316 ti ss; measuring pipe: peek-gf30; gasket: epdm.
accuracy:2% of reading.
repeatability:1%.
temperature limits:process: 32 to 194f (0 to 90c); ambient: 41 to 158f (5 to 70c).
pressure limits:232 psi (16 bar).
response time:< 500 ms.
power requirements:24 vdc 10%.
output:frequency: square-wave, npn; analog: 4 to 20 ma.
loop resistance:250 .
current consumption:max 80 ma.
minimum conductivity of medium:50 s/cm.
flow indication:led green, flow proportional blinking.
enclosure rating:nema 4 (ip65).
process connection:see model chart on catalog page.
electrical connection:plug connector m12x1.
weight:mfs-1x: 1.5 lb (0.68 kg); mfs-2x: 1.7 lb (0.77 kg); mfs-3x: 1.9 lb (0.87 kg).
agency approval:ce.
features
long life cycle with no moving parts to wear or break
can be applied in applications dealing with contaminated media with no mechanical component in the flow
obstruction free pipe cross-section yields low pressure drop
unaffected by change in temperature, density, viscosity or concentration
accessories
model numberdescription
mfs-c34 pin cable socket m12x1 connect, 9.8 ft (3 m)
mfs-c54 pin cable socket m12x1 connect, 16.4 ft (5 m)
mfs-c104 pin cable socket m12x1 connect, 32.8 ft (10 m)
related products
series ppm pulse panel meter
series bat blind analog transmitter
series mfs2 magnetic inductive flow sensor
Application : Water And Other Conductive Liquids.
Brand Name : DWYER USA
Condition : New
Usage : Water And Other Conductive Liquids.
Material : 316 TI SS
Warranty : 1year
Power : 24 VDC 10%.
Type : Magnetic Inductive Flow Sensor
Color : Black
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Paddle Wheel Flow Sensor
Series PFT Paddlewheel Flow Sensor
Non-Magnetic Sensing, Adjustable for 1-1/2 to 40" (38.1 to 1016 mm) Pipe, Pulse or 4 to 20 mA
The Series PFT Insertion Paddlewheel Flowmeters are used to monitor liquid flow rates in pipes from 1-1/2 to 40" and is available in brass or 316 SS body. The unit outputs a frequency proportional pulsed or 4 to 20 mA output. The pulse models are a square wave output signal with frequency proportional to the flow velocity and the 4 to 20 mA models have a linear output of the velocity with 4 mA equal to 0 ft/s and 20 mA equal to 25 ft/s.
Product Applications
Irrigation, Ground water remediation,
Cooling systems,
Pump protectionLeak detection,
Filtration systems
Model Description
PFT-IAN-B111-S-Insertion paddlewheel flow sensor, 4-20 mA output, brass body, 1-1/2" NPT connection, FKM seals, tungsten-carbide shaft, PTFE bearing.
PFT-IAN-S111-S-Insertion paddlewheel flow sensor, 4-20 mA output, 316SS body, 1-1/2" NPT connection, FKM seals, tungsten-carbide shaft, PTFE bearing.
PFT-IDN-B111-S-Insertion paddlewheel flow sensor, pulse output, brass body, 1-1/2" NPT connection, FKM seals, tungsten-carbide shaft, PTFE bearing.
PFT-IDN-S111-S-Insertion paddlewheel flow sensor, pulse output, 316SS body, 1-1/2" NPT connection, FKM seals, tungsten-carbide shaft, PTFE bearing.
Specifications
Service:Water-based fluids.
Range:1.2 to 25 ft/s (0.37 to 7.62 m/s).
Wetted Materials:Body and fitting:Brass or 316 SS;Fitting O-ring:FKM standard, silicone or Buna-N optional;Impeller:316 SS;Shaft:tungsten carbide standard or 316 SS optional;Bearing: PTFE standard.
Linearity:1.0% of FS.
Repeatability:0.5% of FS.
Temperature Limits:-40 to 212F (-40 to 100C).
Pressure Limits:400 psig (27.6 bar) @ 100F (37.8C), 325 psig (22.4 bar) @ 212F (100C).
Process Connection:1-1/2" NPT male standard, 2" NPT male optional.
Output:> Pulse: NPN open collector with square wave output, rated 60 V @ 50 mA maximum.
Frequency: 3.2 to 200 Hz. Pulse Width: 2.5 msec 25%.
4 to 20 mA: 4 mA is 0 ft/s, 20 mA is 25 ft/s.
Power Requirement:10 to 35 VDC.
Power Consumption:40 mA (max).
Electrical Connection:22 AWG shielded UL type PTLC rated 105C, 20'(6.1 m) long with cable gland.Can be extended up to 2000'(609 m) with similar cable.Optional UL listed burial rated cable.
Enclosure Rating:NEMA 6P (IP67) *.
Housing Materials:Brass or 316 SS.
Weight:3 lb. (1.36 kg).
Agency Approvals:CE.*Brass units IP67 only.
Features
Bearings and shaft offer excellent wear protection even in applications with particulate for long life
Weatherproof and submersible rated for irrigation applications
One unit adjustable over a large pipe size range
Multiple wetted material choices offer application versatility
Integral 4 to 20 mA output with no need for additional external components
Sensor technology uses inductive sensing to sense the blades of the impeller therefor does not use magnets allowing low flow rate monitoring with no concerns regarding magnetic material in the flow
Power : 10 To 35 VDC.
Condition : New
Warranty : 1year
Material : Brass Or 316 SS
Type : Paddle Wheel Flow Sensor
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Immersion Temperature Sensors
Series TE-I Immersion Temperature Sensors
Integral Mounting Connection, Welded Thermowells
The Series TE-I Immersion Style Temperature Sensors accurately measure water temperature inside chilled and hot water loops in HVAC systems. Thermowells are required to protect the electrical connection from the process water and to allow replacement of the sensors without draining the system.
For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.
Place your order for the immersion temperature sensors by using our Product Configurator, select one of the IBN, IBG, IBW, ITN, ITG or ITW housing options. Duct housings are also available on this configurator.
Product Applications
Chiller or boiler loops
Building automation
Specifications
Accuracy:Thermistor temperature sensor: 0.22C @ 25C (0.4F @ 77F); RTD temperature sensor DIN Class A: 0.15C @ 0C (0.28F @ 32F).
Temperature Limits:Operating: -40 to 302F (-40 to 150C).
Sensor Curves:See Resistance vs. Temperature Table.
Housing Material:Meets UL, 94 V-O polycarbonate plastic.
Thermowell Material:304 SS.
Thermowell Connections:Internal = 1/2" NPSM; External = 1/2" NPT.
Weight:5.3 oz (150.3 g).
Features
1/4 turn housing cover with chain to prevent dropping
Multiple conduit knockouts for easy installation positioning
Integral 1/2" NPSM connection for direct mounting to a thermowell
General purpose or weatherproof enclosure options
Terminal connection eliminates need for wire nuts
Related Products
Series I2-1 Immersion Temperature Probes
Series S2-1 Surface Mount Temperature Sensor
Series TTW Weatherproof Immersion Temperature Transmitter
Series TE-SNW Weather Resistant Surface Temperature Sensors
Series BTT Temperature Transmitters
Ambient temperature : Operating: -40 To 302F (-40 To 150C).
Warranty : 1yrs
Color : Grey
Certification : YES
Type : Immersion Temperature Sensors
Application : Chiller Or Boiler Loops
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Ultrasonic Level Sensor (Model ULSL)
model ulsl ultrasonic level sensor
18' (5.5 m) measuring range, non-contact transmitter, 4 spst programmable relays
the model ulsl ultrasonic level sensor provides non-contact, continuous ultrasonic level measurement of fluids for short range applications. Ultrasonic technology paired with automatic temperature compensation provides accurate and reliable measurements in almost all conditions. The model ulsl has failsafe logic that is easily configured to custom applications via free software removing the need for target calibration. Using the free software, the model ulsl can be programmed to transmit an output signal as well as set the four relays for control applications. This rugged design comes with a nema 6p submersible enclosure rating to ensure a long lasting unit.
product applications
water and wastewater
pulp and paper processing
sump and process tanks
chemical processing
food and beverage
modeldescription
ulsl-10ultrasonic level sensor, 18' (5.5 m) measuring range, non-contact transmitter, 4 spst programmable relays, 2" npt thread.
(usb adapter necessary for calibration. One adapter can program multiple units.)
specifications
service:compatible fluids.
wetted materials:sensor: pvdf; o-ring: fkm.
ranges:18' (5.5 m).
accuracy:0.2% of range.
resolution:0.079" (2 mm).
blind zone:8" (20 cm).
beam width:3" (7.62 cm).
temperature limits:process: 20 to 140f (-7 to 60c); ambient: -31 to 140f (-35 to 60c).
temperature compensation:automatic.
pressure limits:30 psi (2 bar).
power requirement:12 to 28 vdc.
output signal:4 to 20 ma, 2-wire. Invert: 4 to 20 ma or 20 to 4 ma; fail-safe: 4 ma, 20 ma, 21 ma, 22 ma, or hold last.
loop resistance:400 max.
electrical connections:4' (1.2 m) 9 conductor shielded cable.
contact type:4 spst relays.
contact rating:1 a max @ 28 vdc max.
deadband:selectable (no hysteresis, 1/4", 1/2", 1", 1/2 cm, 1 cm, 2 cm, 5 cm or not available).
process connection:process connection: 2" npt, 2" bspp (optional).
enclosure rating:nema 6p (ip68).
enclosure material:polycarbonate; gland: tpe.
mounting orientation:vertical.
memory:non-volatile.
failsafe:contact: power loss: hold last contact; power on: open, close, or last contact.
programming:free pc software download (usb adapter required).
weight:3 lb (1.36 kg).
agency approvals:ce, rohs.
features
has a 18 (5.5 m) measuring range with a 0.2% of range accuracy
via free software, units can be programmed to transmit an output signal and operate four relays for control applications
provides reliable, accurate, and non-contact level measurement of compatible liquids
non-contact technology offers no moving parts to wear, jam, corrode, or get coated like contact technologies
mapping software makes effective measuring surface only a 3" (76.2 mm) diameter column with no concerns of ladders, pipes, or other tank intrusions in the remaining sound cone
ultrasonic technology paired with automatic temperature compensation provides accurate and reliable measurements in almost all conditions
fail-safe logic is easily configured to custom applications via free software removing the need for target calibration
full nema 6p submersible enclosure rating to ensure excellent product durability
Warranty : 1yrs
Usage : Compatible Fluids.
Color : Black
Certification : YES
Voltage : 12 To 28 VDC.
Brand Name : DWYER USA
Weight : 3 Lb (1.36 Kg).
Material : Sensor: PVDF; O-ring: FKM.
Type : Ultrasonic Level Sensor
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
EOS Wireless Occupancy Sensor
the series eos wireless occupancy sensor uses en ocean technology to enable a new level of energy saving control for rooms, hallways, and other common areas. Using a pir motion sensor to detect movement in a space, the eosc models have a 360 degree viewing angle and the eosw models offer wide angle and long range lenses in the same package. The enocean technology allows for wireless communication with any other enocean-enabled devices.
features:
energy harvesting, no power supply or batter necessary
ceiling mount option for a large coverage area or flat wall/corner mount in one design
energy and cost savings by determining if lights or hvac should be turned off based on room occupancy
meets north american and european standards
applications:
lighting or hvac control
feedback to building management system that a space is occupied
model available:
modeldescription
eosca-w-eoenocean ceiling mount occupancy sensor, 868 mhz
eoscu-w-eoenocean ceiling mount occupancy sensor, 902 mhz
Usage : Feedback To Building Management System That A Space Is Occupied
Material : ABS
Condition : New
Color : Black
Power : 3 To 5 VDC
Warranty : 1year
Type : EOS Wireless Occupancy Sensor
Brand Name : Dwyer USA
Application : Industrial Use, Lighting Or HVAC Control
Range EOSC 40' (12 m) diameter; EOSW with wide angle lens 50' (15 m); EOSW with long range lens 100' (3 : Weight G 0.42 oz (12 g).
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
Particulate Sensor (Series PMS)
series pms particulate sensor
reliable operation, minimal maintenance
the pms particulate sensor employs a field-proven combination of passive-induction and protected-probe technologies. As particles flow near and around the probe, minute currents are dynamically induced into the probe by flowing particulate. A dsp processes the signal into an absolute output that is reasonably linear to mass. Protective layers over the probe work in combination with induction-sensing to ensure reliable operation with all types of particulate including moist powders and highly conductive dusts. Maintenance is minimal and there is no need for an air purge. For durability, the sensors are passive and free of electronics. The pms particulate sensor is designed to be used with the dpm particle monitor in order to be intrinsically safe.
product applications
baghouses
cartridge filters
bin vents
specifications
service:air and compatible gases, any type particulate.
wetted materials:304ss and ptfe.
temperature limits:ambient: maximum -40 to 392f (-40 to 200c) (maximum must be calculated for each application).
process:see catalog page.
pressure limits:standard: full vacuum to 10 psi (0.69 bar); optional: 100 psi (6.89 bar).
output signal:pa.
electrical connection:low noise coaxial.process connection:see catalog page.
enclosure:standard: painted cast aluminum, weatherproof, nema 4x; optional: intrinsically safe, csa.
weight:varies depending on length of probe and type of mount.
agency approvals:ce, csa.
features
durable housing that is free of electronics
minimal maintenance needed
related products
series tfls tuning fork level switch
series tfls tuning fork level switch
series dct1000 dust collector timer controller
series dct1000 dust collector timer controller
series dct500a low cost timer controller
series dct500a low cost timer controller
series cls2 capacitive level switch
series cls2 capacitive level switch
series pls paddle level switch
series pls paddle level switch
series dpm particulate monitor
series dpm particulate monitor
series dct600 timer controller
series dct600 timer controller
Application : Any Type Particulate.
Material : 304SS And PTFE.
Type : Particulate Sensor
Color : GRAY
Warranty : 1year
Condition : New
Power : 6W
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Duct And Immersion Building Automation Temperature Sensor
Series TE Duct and Immersion Building Automation Temperature Sensor
Available up to 18" Probe Length, Thermistor or RTD Outputs
The Series TE Duct and Immersion Temperature Sensor can be used to monitor air or water temperature throughout a building management system or an air handler unit. Flanged duct sensors monitor the supply or return air and provide a thermistor or RTD output to the digital controller. Immersion sensors which are supplied with compression fittings are typically used to monitor the hot or chilled water lines throughout a building. Thermowells are recommended, but not required on the immersion sensors.
For variable air volume applications, the Series TE can be configured to have 8' plenum rated cable with flying leads. Standard units come with 4" leads with an integral terminal block to eliminate carrying extra wire nuts. For housing models, multiple knockouts provide easy conduit access to any side of the housing. The 1/4 turn lid comes with a chain to prevent it from being lost during installation.
For models with resistive thermistors or RTD outputs, please click here for temperature to resistance lookup tables.
Product Applications
Building automation
VAV temperature sensing
Chiller or boiler loops
AHU monitoring
Specifications
Accuracy:Thermistor temperature sensor: 0.22C @ 25C (0.4F @ 77F); RTD temperature sensor DIN Class A: 0.15C @ 0C (0.28F @ 32F).
Temperature Limits:Operating: -40 to 302F (-40 to 150C).
Sensor Curves:See Resistance vs. Temperature Table.
Cable Rating:Plenum option includes UL listed plenum cable.
Housing Material:Meets UL, 94 V-O polycarbonate plastic.
Thermowell Material:TE-I: 304 SS.
Housing Rating:NEMA 4X (IP66) (DFW, IBW only).
Weight:5.3 oz (150.3 g).
Agency Approvals:Meets the technical requirements of EU Directive 2011/65/EU (RoHS II).
Features
Easy to mount external tab housing and flange options for duct applications
1/4 turn housing cover with chain to prevent dropping
Multiple conduit knockouts for easy installation positioning
8 plenum rated cable option
Terminal connector eliminates need for wire nuts
Related Products
Series MS Magnesense Differential Pressure Transmitter
Series MS Magnesense Differential Pressure Transmitter
Series RHP Humidity/Temperature Transmitter
Series RHP Humidity/Temperature Transmitter
Series RHP-W Wall Mount Humidity/Temperature/Dew Point Transmitter
Series RHP-W Wall Mount Humidity/Temperature/Dew Point Transmitter
Series TE-WSS Stainless Steel Wall Plate Temperature Sensor
Series TE-WSS Stainless Steel Wall Plate Temperature Sensor
Type : Duct And Immersion Building Automation Temperature Sensor
Warranty : 1yrs
Color : Light White
Application : Building Automation
Ambient temperature : Operating: -40 To 302F (-40 To 150C).
Certification : YES
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
wall mount occupancy sensor
model osw-100 wall mount occupancy sensor
wide viewing angle, easy to install
the model osw-100 wall mount occupancy sensor is an infrared sensor designed to automatically control an hvac ventilation system. A unique dual delay processor eliminates false triggers due to short-term occupancies. The model osw-100 has a wide 110 viewing angle to capture movement up to 49.2 ft (15 m) away.
modeldescription
osw-100wall or corner mount infrared dual element occupancy sensor.
specifications
infrared sensor:dual element.
range:49.2 ft (15 m).
detectable speed:0.33 to 9.8 ft/sec (0.1 to 3.0 m/sec).
control output rating:spdt, 0.2a @ 30 vdc.
ambient operating temperature:-4 to 140f (-20 to 60c).
power consumption:standby: 5 ma, operating: 18 ma.
mounting height:5.9 to 11.8 ft (1.8 to 3.6 m).
power requirements:22 to 26 vac/dc.
weight:3.2 oz (90.7 g).
agency approvals:ce.
related products
series rhp-w wall mount humidity/temperature/dew point transmitter
series rhp-w wall mount humidity/temperature/dew point transmitter
series te-wss stainless steel wall plate temperature sensor
series te-wss stainless steel wall plate temperature sensor
material : plastic, abs
application : industrial use
color : white
brand name : dwyer usa
type : occupancy sensors
condition : new
warranty : 1year
alarm range : 49.2 ft (15 m).
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week
In Flow Sensors (Series DS In Flow Sensors)
series ds in-line flow sensors
use with the dwyer differential pressure gages or transmitters
the series ds in-line flow sensors are two series of averaging pitot tubes for compatible gases and liquids that provide accurate and convenient flow rate sensing, for schedule 40 pipe, when purchased with suitable differential pressure gage with appropriate range.
the series ds-300 averaging flow sensors are designed to be inserted in the pipeline through a compression fitting and available for pipe sizes from 1 to 10" (2.5 to 25.4 cm). Accessories include adapters with 1/4" sae 45 flared ends compatible with hoses supplied with the model a-471 portable capsuhelic gage kit.
the series ds-400 averaging flow sensors are designed for insertion lengths up to 24" (61 cm) and include a pair of 1/8" npt x 1/4" sae 45 flared adapters which are compatible with hoses used in the model a-471 portable capsuhelic gage kit. The supplied solid brass mounting adapter has a 3/4" dia. Compression fitting to lock in required insertion length and a 3/4" male npt thread for mounting in a threaded branch connection (not included).
product applications
remediation
natural, flare, flue, stack gas
boiler feedwater
cooling water
superheated, saturated, or geothermal steam
combustion or compressed air
oil flow monitoring
modeldescription
ds-300-1flow sensor, 1" pipe size.
ds-300-10flow sensor, 10" pipe size.
ds-300-10-lvflow sensor, 10" pipe size, without valves.
ds-300-1-1/2flow sensor, 1-1/2" pipe size.
ds-300-1-1/2-lvflow sensor, 1-1/2" pipe size, without valves.
ds-300-1-1/4flow sensor, 1-1/4" pipe size.
ds-300-1-1/4-lvflow sensor, 1-1/4" pipe size, without valves.
ds-300-1-lvflow sensor, 1" pipe size, without valves.
ds-300-2flow sensor, 2" pipe size.
ds-300-2-1/2flow sensor, 2-1/2" pipe size.
ds-300-2-1/2-lvflow sensor, 2-1/2" pipe size, without valves.
ds-300-2-lvflow sensor, 2" pipe size, without valves.
ds-300-3flow sensor, 3" pipe size.
ds-300-3-lvflow sensor, 3" pipe size, without valves.
ds-300-4flow sensor, 4" pipe size.
ds-300-4-lvflow sensor, 4" pipe size, without valves.
ds-300-6flow sensor, 6" pipe size.
ds-300-6-lvflow sensor, 6" pipe size, without valves.
ds-300-8flow sensor, 8" pipe size.
ds-300-8-lvflow sensor, 8" pipe size, without valves.
ds-400-10flow sensor, 10" pipe size.
ds-400-10-lvflow sensor, 10" pipe size, without valves.
ds-400-12flow sensor, 12" pipe size.
ds-400-12-lvflow sensor, 12" pipe size, without valves.
ds-400-14flow sensor, 14" pipe size.
ds-400-14-lvflow sensor, 14" pipe size, without valves.
ds-400-16flow sensor, 16" pipe size.
ds-400-16-lvflow sensor, 16" pipe size, without valves.
ds-400-18flow sensor, 18" pipe size.
ds-400-18-lvflow sensor, 18" pipe size, without valves.
ds-400-20flow sensor, 20" pipe size.
ds-400-20-lvflow sensor, 20" pipe size, without valves.
ds-400-24flow sensor, 24" pipe size.
ds-400-24-lvflow sensor, 24" pipe size, without valves.
ds-400-6flow sensor, 6" pipe size.
ds-400-6-lvflow sensor, 6" pipe size, without valves.
ds-400-8flow sensor, 8" pipe size.
ds-400-8-lvflow sensor, 8" pipe size, without valves.
Warranty : 1year
Type : In Flow Sensors
Condition : New
Brand Name : DWYER USA
Color : GRAY
Pipe Sizes DS-300 1 to 10" (2.5 to 25.4 cm); DS-400 6 to 24 " (15.2 to 61 cm). : 1/8
Temperature 200 Degree F (93.3 Degree C) : Pressure Range 200 psig (13.78 bar) at 200 Degree F (93.3 Degree C
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T
Delivery Time : 4-6 week