Our Product / Services
Speed, Simplicity and Affordability
The new OHAUS MB23 and MB25 Basic Moisture Analyzers combine high quality and durable construction into a sleek, compact design. The MB23 and MB25 offer dependable, accurate, results for a wide
variety of applications.
Standard Features Include:
Industry Leading Quality and Support
All OHAUS MB Series Moisture Analyzers are manufactured under an ISO 9001:2000 Registered Quality Management System. Our rugged construction and stringent quality control have been hallmarks of all OHAUS products for over a century.
Outline Dimensions
Specifications
Model | MB23 | MB25 |
---|---|---|
Capacity | 110g | |
Repeatability (Std Dev) (g) | 0.3% (3g sample) 0.2% (10g sample) |
0.2% (3g sample) 0.05% (10g sample) |
Readability | 0.1% / 0.01g | 0.05% / 0.005g |
Sample Size | 3g to 20g typical, 0.5g min. | |
Interface | Bidirectional RS-232 | |
Timer | 1 - 99 minutes, 30-second increments to 60 minutes | |
Heating Technology | Infrared (no glass) | Halogen |
Temperature Range | 50°C to 160°C in 5° increments | |
Power | 100 to 240 VAC, 50/60 Hz | |
Tare Range | To capacity by subtraction | |
Operating Temperature Range | 5° to 40°C | |
Display Type | Custom backlit LCD | |
Displays | % moisture or % solids or weight (g), temperature, time | |
Pan Size (Diameter) | 90 mm | |
Dimensions (W x H x D) | 17 x 13 x 28 cm | |
Net Weight | 2.3 kg | |
Shipping Weight | 3.9 kg | |
Included Accessories | ||
Sample Pans (Quantity 50) | Standard | |
In Use Cover | Standard | |
Sample Pan Handler | Optional (PN 11113873) | Standard |
Models are CE, CSA/UL and FCC approved
Details
Options and Accessories | Ohaus Number |
Security Locking Cable | 80850000 |
Security Lock (Kensington® type) | 80850043 |
Temperature Calibration Kit | 11113857 |
50g M1 Calibration Weight | 11117146 |
Sample Pans (80/Box) | 80850086 |
Pads, Glass Fiber (200/Box) | 80850087 |
Reusable Sample Pans (3/pk) | 80850088 |
STP103 Thermal Printer EU | 80251993 |
STP103 Thermal Printer UK | 80251994 |
CBM910 Impact Printer EU | 80252043 |
SRP275 Impact Printer UK | 80251989 |
Cable, STP103 | 80252581 |
Cable, CBM910 | 80252571 |
Cable, SRP275 | 21253677 |
Collect Software | 80500746 |
MY Q HYDROSTATIC PRESSURE TESTER (MANUAL MODEL)
Based in Delhi, My Q Instruments has been recognized for offering the best machine calibration service. We have a team of calibration engineers who specialize in ensuring the instruments and machines are calibrated well, exactly for their standard readings and optimum tolerance range. Our team ascertains that all the incorrect measurements are carefully catered to so that production line is not at all compromised and high-quality products can be produced on a timely basis.
Features :
Features :
Technical Specifications
Model | 603 | 405 | 410 | 420 |
---|---|---|---|---|
Tank Capacity(liter) | 3.3 | 5.7 | 10 | 20 |
Features :
My QShade Card-Winding Machine consists of a set of grips between which the card is held with the help of knurling bolts. There is an arrangement of gears to rotate both grips at a time. Yarn is wind over the shade card at equal spacing under a desired tension. The yarns are guided on the shade card with the help of yarn guides, which are moves parallel to the shade card with the help of the worm / worm wheel and cam/ follower mechanism. The guide is positively linked to the rotation of the shade card with the help of the worm/ worm wheel, shaft and cam/ follower mechanism. There are a set of spring loaded adjustable tensioning arrangement provide the desired tension to the yarn. For holding the reels, there is a stand on which the holding pins and guides for yarn etc. are mounted for easy movement of the yarns.
The equipment is built on the fabricated base. It is finished in metallic or deco painting and bright chrome/ zinc plating to give it a corrosion resistance finish.
Features :
Accuracy - For refractive index 0.001 by direct reading on scale & +0.0001 by estimation. For sugar solution 0.05% by direct reading scale & 0.1% by estimation.
Features :
Details :
The MYQ MAGNETIC STIRRER is specially designed for textile Laboratories to heat liquids continuously at high temperature.
This Evaluation Booard is Designed For evaluation of Smoothness in Appearance of Flat fabric and Seams and the Retention of Pressed Or crease in arments and other Texttile Products after Repeated Home Laundering. this is also Used to Evaluate the Wrinkling Recovery of The fabrics After Undertaking the Wrinkle Recovery test.
Equipment Details
the Myq Viewing Board (aatcc)consists of a Wide Board At 85° with the Cool white fluorescent Lamp Fixed At Top. Aspear 500 watt Flood Lamp with Standard
condition, a Light Shield is also Provided to Minimize the Interference of Flood lamplight Directly Going to the Viewer eye. the Board is Duly Painted as Per grey Chip No.2 of Aatcc Staining Grey scale to Meet the Specification Of american Standards.
Salient Features
Test Method
AATCC- 88B/88C/124/128/143/178
Technical Detals
Power Supply | 220/230v, 50hz, Single phase, 50hz, Ac Supply |
---|---|
Top Light Source (cwf 4) | 04 Nos (36watts) |
Reflector Flood Lamp | 500watt |
Overall Dimensions | 2350(l) ×2311(w) ×1803(h)mm 92.5(l) ×91(w) ×71(h) |
Net Weight of the Unit | 150 Kg(approx )(330lb) |
Accessories
Main unit | 01 No. |
Specimen Holder Board | 01 No. |
Fluorescent Reflector | 01 No. |
Flood lamp (500watt) | 01 No. |
Tube lights (CWF 4°) | 01 No. |
Light shield | 01 No. |
Top light unit | 01 No. |
Detailed user’s manual | 01 No. |
Calibration certificate | 01 No. |
My Q is one of the reputed manufacturers, suppliers, and traders of Home Furnishing Needle Detector. Massively used for garment, shoes, home furnishing Items and toys, these efficient machines come with user-friendly operating system. In the proffered series, magnetic induction method is used for detection.
Features:
Technical Specifications
Model Name | MyQ-680CE-100 | MyQ-680CE-200 | MyQ-680CE-300 |
---|---|---|---|
Detecting Method | Magnetic Induction | Magnetic Induction | Magnetic Induction |
Detecting Ability | 0.8/1.0mm(Dia)FE | 1.5 mm (Dia) FE | 2.5 mm (dia)FE |
Detecting Adjustment | Step less adjustment | Step less adjustment | Step less adjustment |
Detecting Width | 600 mm | 600 mm | 600 mm |
Detecting Height | 100 mm | 200 mm | 300 mm |
Alarm Mode | Buzzer & Belt Stops | Buzzer & Belt Stops | Buzzer & Belt Stops |
Belt Speed | 30 M/min | 30 M/min | 30 M/min |
Power Supply | 220v.50HZ, single phase | 220v.50HZ, single phase | 220v.50HZ, single phase |
Rated Output | 110 W | 110 W | 110 W |
Dimension (LXWXH) | 1650(L)X1050(W)X900(H)mm | 1650(L)X1050(W)X900(H)mm | 1650(L)X1050(W)X900(H)mm |
Weight | 200 kg Approx | 250 kg Approx | 300 kg Approx |
Colour Matching Cabinet is used for Colour Matching under different light sources the equipment is tted with ve Light Sources as per Intemational Standards.
Supplied with
A Muffle furnace in historical usage is a furnace in which the subject material is isolated from the fuel and all of the products of combustion, including gases and flying ash. After the development of high temperature electric heating elements and widespread electrification in developed countries, new muffle furnaces quickly moved to electric designs.
Technical Details
Specification | MYQMF S/G-2 | MYQMF S/G-4 | MYQMF S/G-7 |
Temperature | Working Temperature: 950°C (or as per requirements) | ||
Maximum Temperature: 1000°C (or as per requirements) | |||
Internal Size (W x D x H) cm | 22 x 10 x 10 | 25 x 12 x 12 | 30 x 15 x 15 |
External Size (W x D x H) cm | 55 x 70 x 75 | 65 x 75 x 75 | 70 x 90 x 85 |
Shipping Weight - kg (lb) | 90 (198) | 105 (231) | 115 (253) |
Power (Watts) | 1800 | 2200 | 3500 |
Material | Inner Chamber: High temperature resistive ceramic | ||
Outer Chamber: Mild Steel Powder Coated/ SS 304 Grade |
Details
Siedentopf observation head inclined at 30 degree rotatable at 360
Diopter adjustment ring on ocular tube. Interpupillary distance from 55mm to 75mm
Eyepiece EWF 10x fov 18MM
Objectives E plans achromatic 4X, 10X, 40X, 100 oil
Mechanical body – co-axial focusing system. Pre-focusing lever & tension adjustment ring. The slow motion has 1Div = 0.002 mm
Reverse angle quadruple nosepiece revolves on ball bearing
Mechanical stage size 125mm x 135mm having low positioned co-axial control on ball bearing
Built in base illumination system with 6V /20w halogen bulb and power supply
Cross movement 55mm x 74mm
Stage condenser-abbe condenser N.A 1.25 swings out filter, iris diaphragm.
Hidg resolution digital camera eyepiece- high resolution 1282 x 1024 CCD digital camera. It adopt it high performance USB. The transmission speed is 30 f/s.
MYQ Melt Flow Indexer, often abbreviated as "MFI", is an affordable-price tabletop instrument used to test the melt flow resistance (MFR) of a wide range of thermo-plastic materials. The tester conforms to all National and International melt flow resistance standards, including BS EN ISO 1133 and ASTM D1238. Any temperature within 120°C-450°C (248°F-842°F) can be accurately controlled.
Included weights
Features
Accessories
The Melt Flow Indexer is supplied with all the accessories and weights necessary for maintenance and operation. Nothing else to buy!
My Q Laboratory Padding Mangle is a versatile laboratory machine with wide applications in Dyeing, Printing & Finishing processes. By simulating the production level process parameters on laboratory scale satisfactory results can be obtained with JK &PC. Padding Mangle. Two bowl Vertical Padding Mangle has bowls coated with synthetic rubber. In standard supply, shore hardness of the rubber is 70 shore hardness.
My Q magna scope is useful to evaluate dyeing, printing , weaving defects or constructional difference in any type of fabrics. Light source from top & bottom facilities in the assessment.
Magnification- 10 x
Total weight 11 kg (approx)
My Q handy metal detector is useful to detect exact position of broken needle or any ferrous particle in garments. Highly accurate, hand held model for spot detecting.
Sensitivity - 1.2 mm
My Q AATCC Perspirometer Helpful for determining the resistance of the color of Textiles of all kinds and in all forms to the action of Human perspiration. Color Fastness of Dyed or printed fabrics, against perspiration, is determined by exposing the fabric sample to the action of both alkaline and acidic reagents, while in contact with undid adjacent fabrics on both sides. The test specimen along with adjacent fabric is placed between plastic (Acrylic) Separator plates, under a fixed load, inside an Incubator maintained at 37 C.
Accessories
Features of Perspirometer:
Details :
Details :
Delhi Based, My Q Instruments has been recognized for offering the best machine repairing service. We are working with an affluence of technical expertise and professionalism, our provided solutions comply with the codes of international quality norms. We have a team of engineers who are specialize in ensuring the machines are repaired well, exactly for their standard readings and optimum tolerance range.
We are the main supplier of this product.
We are the main supplier of this product.