Our Products
Electrical Components
2 Products availableClamps
2 Products availableLeading Manufacturer, Supplier & Retailer of Power Quality Analyzer, Battery Analyzer, CT PT Analyzer, Single Phase Power Quality Analyzer and Portable Three Phase Power Quality Analyser.
Power Quality Analyzer is used to measure log power quality parameters as defined by IEC 61000-4-30 (class A). Our Power Quality Analyzer facilitates steady-state voltage deviation. In addition, it comes with long-term and short-term flicker perceptibility. We have gained many accolades for exporting and supplying high reliable and durable Power Quality Analyzer.
Instrument Ccreen Shots
Measured Parameters Can Be Applied For
Power quality parameters (under- and overdeviation of voltage, frequency deviation as defined by IEC 61000-4- 30, class A |
AC power certification»; measurement results can be used in arbitration as a proof of compliance/non-compliance of AC power to the quality declared by a distributor |
---|---|
Accidental events : • voltage interruptions • dips, • swells |
Detection and analysis of emergency situations Short circuits, power cutoffs, distorting loads, overloads etc. |
Active power of: • harmonics • negative sequence • zero sequence |
Active power of: • harmonics • negative sequence • zero sequence |
• Voltage (0.1–600V), • Current (0.01–3500A), • Active, reactive and apparent power • Power factor |
Energy savings Logging of these values make it possible to build detailed graphs of consumer demand (consumer load graphs) and achieve energy savings by discovering energy wastes and, e.g., deciding on measures for reactive load compensation Energy efficiency classification Logging of power consumption data makes it possible to classify appliances with respect to power consumed in various operation modes |
Active (kWh) and reactive (kVarh) energy (export and import), phase and phase-to-phase angles for currents and voltages, vector diagram |
Inspection of meter reading and billing systems Check of meter’s connectivity and performance; testing of AMR systems |
Active energy (kWh) (measured synchronously by two class A instruments) |
Determining energy losses in power transmission lines Makes it possible to localize points with limits-exceeding energy losses (focusing on either technical or commercial aspect) |
This is an advanced Battery resistance tester. It can be used for evaluation of perfomrance of single battery cell and the string of battries.
The battery resistance tester has powerful data management capability. User and open and playback the data records, Send data to U diisk, Delete , format the data and such management functions are available.
System management function include clock settings. Parameter calibration. Language Selection. Waveform test, system updates and software version information.
Instructions for use the tester are available onboard : to provide users with help information, all problems are summarized as basic knowledge by type. On-site wiring information is available in the help as well as information about tester operation. tester maintenance, etc.
Specifications:
Resistance range: 0.0 mOhm to 120 mOhm
Voltage range : 0.000V to 20 V
Resolution :
Resistance 0.001 mOhm
Voltage : 1 mV
Accuracy:
Resistance : 1 %
Voltage : 0.5%
Display type: TFT LCD Touch screen
Display size : 4.3", 272 x 480
Tester weight: 450 gm
Tester size: 18.6 x 9.8 x 4 cm
Memory capacity: 100000 test data items.
Internal power supply : 4000 mAH lithium Ion Battery
Operation time on full battery capacity: Between 8-12 hours
External Power supply : 100-240 V ac/ 5 V DC- 1 A Power adopter- charger
Communication interface : USB
Major features:
Test reports can be imported in excel and word files
4 wire test clamps are available
4 wire test probes are available
Battery resistance tester can be order with A) Set of Test clips B) Set of Test Probes or C) Set of Test clips and Set of Test probes.
Additional Information:
Delivery Time : 4-6 weeks
The CT PT Analyzer conducts examinations based on excitation characteristics, transformation ratio, polarity, demagnetize, and 5 and 10 error curves, while conducting a secondary circuit check. The CT PT Analyzers withstand power frequency tests for alternating current and secondary load. As an Exporter and Supplier of CT PT Analyzer, the company offers the best equipment for field testing of CT and PT protection and metering types. The LCD display, integrated thermal printer, and USB port are some of the key components of the CT PT Analyzer.
Functions for testing
Functions for testing PT
Tekon550 power quality analyzer is the world's only single-phase power analyzer that can measure 1p2w, 3p3w (balance), 3p3w (imbalance), 3p4w by sequential measurement method.
Tekon550 also allows laboratory personnel, production facility maintenance professionals and electricians to troubleshoot and benchmark power quality issues in their daily jobs.
Features :
Tekon550 can be powered by NiMh battery pack or with power adaptor having internal charger. Tekon550 unit has built in real time clock as well as back light function.
Additional Information:
Payment Terms : T/T
TEKON 560 Series power Quality analyzers are hand held instruments that accurately measure, diagnose and analyze electrical power characteristics and parameters of power distribution and communication related systems. By incorporating a 7-inch wide touch screen into its lightweight design, they maximize user convenience, allowing the user to perform power quality logging and analysis.
The system allows you in the most effective and easiest manner to perform measurement, data storage analysis and output via the 7" wide LCD screen, in addition a function of transferring measurement data to remote locations by using a mobile app.
Measurement functions :