Our Product / Services
Dwyer Instruments Partner ENVIRO TECH in India
dwyer mtl7706 zener barrier
overview
features
description
thedwyer mtl7706/7787is an intrinsically safe (is) shunt-diode barrier that can be used to communicate with and provide isolations for certaindwyer transmitters approvedfor use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.
product applications
| mtl7706 | intrinsically safezener barrier. |
| mtl7787 | intrinsically safezener barrier. |
Additional Information:
Payment Terms : T/T,
Delivery Time : 4-5 WEEK
dwyer mtl7787 zener barrier
overview
features
description
thedwyer mtl7706/7787is an intrinsically safe (is) shunt-diode barrier that can be used to communicate with and provide isolations for certaindwyer transmittersapproved for use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.
product applications
Additional Information:
Payment Terms : T/T,
Delivery Time : 4-5 WEEK
dwyer instruments 2000-500pa-asf
select the magnehelic gage for high accuracy--guaranteed within 2% of full scale--and for the wide choice of 81 models available to suit your needs precisely. Using dwyer's simple, frictionless magnehelic gage movement, it quickly indicates low air or non-corrosive gas pressures--either positive, negative (vacuum) or differential. The design resists shock, vibration and over-pressures. No manometer fluid to evaporate, freeze or cause toxic or leveling problems. It's inexpensive, too. The magnehelic gage is the industry standard to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid levels with bubbler systems and pressures in fluid amplifier or fluidic systems. It also checks gas-air ratio controls and automatic valves, and monitors blood and respiratory pressures in medical care equipment
product highlights
Additional Information:
Payment Terms : T/T,
Delivery Time : 15 day
Calibration Pump Dwyer Model A-396A
Model A-396A Calibration Pumpgenerates up to 72 psig, integral bleed fittingserves as pressure sourceto calibrate gages and transmitters or to set pressure switches. Use with manometer or other pressure standard. Includes volume adjuster enabling fine pressure control and bleed valve. Generates pressures from a fraction of an inch w.c. To 72 psig (5 bar). Includes barbed fitting, tee connector and three 36" lengths of vinyl tubing.
Model
Description
Related Products
Additional Information:
Payment Terms : T/T,
Delivery Time : 4-5 WEEK
dwyer zener barrier
series mtl7706/7787 zener barrierintrinsically safe barriers for hazardous locations
the mtl7706/7787is an intrinsically safe (is) shunt-diode barrier that can be used to communicate with and provide isolations for certaindwyer transmitters approvedfor use in hazardous areas. These barriers limit the amount of energy allowed to pass into the hazardous area, which inhibit ignition in flammable atmospheres.
product applications
| mtl7706 | intrinsically safezener barrier. |
| mtl7787 | intrinsically safezener barrier. |
Additional Information:
Payment Terms : T/T,
Delivery Time : 4-5 WEEK
model mst2-01 digital moisture meter
measures moisture, temperature and relative humiditythe model mst2-01 digital moisture meteris a high-accuracy instrument used for determining the moisture content in wood, bamboo, and other various materials. This unit also has the ability to measure ambient temperature and relative humidity. The large digital lcd makes measurements easy to read, while the hold function makes them easy to record. Themst2-01includes a protective cap, two replacement pins, and one battery.
specifications
Additional Information:
Payment Terms : T/T,
Delivery Time : 4-5 WEEK