    • Accuracy± 0.5% of measured value (calibrated) at reference conditions
    • Repeatability± 0.2% of span
    • Media PressurePN 40 upto DN 80, PN 16 upto DN 200, PN 10 upto DN 600
    • Response Time5 seconds 
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 19 Years
    • building Nature of Business Retailer
    • Year of Establishment 2004

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Accuracy± 0.5% of measured value (calibrated) at reference conditions
    • Repeatability± 0.2% of span
    • Media Temperature (PTFE)0o - 180o C with Remote transmitter 0o - 120o C with Integral transmitter 0o - 90o C max for other liners
    • LinerPTFE / Neoprene / Polyurethane
    • Response Time5 seconds 
    • For Flow between 20 to 100%± 1% of measured value (normal)
    • LED Display4 Digit Indication for Flow Rate and 8 Digit Indication for Totaliser Programming from Front Keyboard for Engineering Units
    • For Flow between 0 to 20%Refer Error Diagram below
    • Ambient Temperature Range0o - 50o C
    • Ingress ProtectionIP - 65 (IP - 68 on request)
    • Coil HousingCarbon Steel / SS, Epoxy painted
    • Flow Velocity Range0.3 to 10 m/s
    • Power Consumption20 VA
    • Effect of Power SupplyLess than 0.1% per 10% Voltage variation
    • Suitable for Pipe SizesDN 10 to DN 600
    • Effect of Ambient TemperatureLess than 0.2% per 1o C
    • Maximum Load Resistance1000 Ω
    • ElectrodeSS / Hastelloy C / Ta / Ti / Pt
    • TransmitterCast Aluminium (LM6), Epoxy painted
    • Power SupplyNominal
    • Flange / End Connection Std.DIN / ANSI / BS / SMS / TRI-CLAMP
    • Analog Output (Isolated)4-20 mA DC / 0-20 mA DC
    • Pulsed Output (Optional)Low Pulsed Rate Output 10 to 36000 pulses per hour
    • Ambient Temperature25o C + 2o C
    • Communication Port (Optional)RS - 232 / RS - 485 MODBUS RTU Protocol
    • Media PressurePN 40 upto DN 80, PN 16 upto DN 200, PN 10 upto DN 600
    • Effect of Load ResistanceLess than 0.1% of span
    • Media Conductivity (Min.)10 μS/cm (Consult factory for 5 μS/cm)
    • Load Resistance500 Ω
    • End Connections / FlangesCarbon Steel / SS 304 / SS 316 / SS 316L
    • Cable Gland Entry1/2" NPT (F)
    • Materials : 
    • Power Supply110 / 240V AC ± 15%, 50Hz
    • PipeSS 316 (Non - magnetic )

    Crystal Series 6400 is a new range of Bipolar Pulsed DC Full Bore Type Electromagnetic Flowmeters. It is suitable for pipes with diameters of 10 mm to 600 mm. They are based on Faraday’s law of Electromagnetic Induction. The meter features flanged construction and is available with choice of Liner and Electrode materials. Series 6400 has excellent accuracy and flow rangeability. The meter is suitable for use on wide range of corrosive and aggressive range of conductive liquids.

    Salient Features
    • Based on Faraday’s law of Electromagnetic Induction.
    • Suitable for pipe sizes of diameters 10 mm to 600 mm
    • Coil Assembly in hermetically sealed Welded construction
    • Choice of PTFE / Neoprene Rubber / Polyurethane liners
    • Integral or Remote Transmitter
    • Field interchangable electronics
    • Optional LED display for Flow Rate or Totaliser indication in Engineering Units
    • No pressure loss
    • High linerarity due to characteristic magnetic field
    • Absolute Zero stability and noise elimination
    • Measurement independent of liquid properties

     

    Operations

     

    Electromagnetic Flowmeters are based on Faraday’s law of Electromagnetic Induction.
    In a Electromagnetic Flowmeter, magnetic field is generated by a set of coils. As the conductive liquid passes through the electromagnetic field, an electric voltage is induced in the liquid, which is directly proportional to its velocity. This induced voltage is perpendicular to both the liquid flow direction and the electromagnetic field direction. The voltage sensed by the electrodes is further processed by the transmitter to give standardised output signal or displayed in appropriate Engineering Units on LED Display.
    The flux density of the electromagnetic field in a given Flowmeter and the distance between the electrodes are constant, therefore, the induced voltage is only a function of liquid velocity.



    Applications
    Chemical, PetrochemicalDrug IndustriesSteel Industries
    Process IndustriesSugar IndustriesMining Industries
    Fertilizer IndustriesBeverage IndustriesDredging Industries
    Pharmaceutical IndustryPaper and Pulp IndustriesWater and Waste-Water Management
    Food IndustryAluminum IndustriesAnd many others
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    Looking for ELECTROMAGNETIC FLOWMETER REMOTE TYPE?

    Quantity
    Seller Contact Details
    To list your productBoost Your Business Visibility WorldwideRegister Now
    To list your productBoost Your Business Visibility WorldwideRegister Now
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice