My ExportersIndia

For Buyer

For Seller

For Help

Our Product / Services

  1. Calibration Equipment 16 Products / Services available
  2. Calibrators And Monitoring Systems 16 Products available
  3. Calibrators 6 Products / Services available
  4. Digital Indicator 5 Products available
  5. Calibrating Machine 5 Products available
  6. PH Meter 5 Products available
  7. Laboratory Bath 3 Products available
  8. Pressure Gauges 3 Products available
  9. Electronic Test Instruments 3 Products available
  10. Moisture Meter 2 Products available
  11. Thermocouple 2 Products available
  12. Process Control Equipment 2 Services available
  13. Measuring Instruments & Equipment 2 Products available
  14. Electronic Timers 2 Products available
  15. Laboratory Equipments 2 Products available
  16. Limit Controller 2 Products available
  17. Industrial Humidifier 1 Products available
  18. Differential Pressure Gauge 1 Products available
  19. Variable Frequency Drives 1 Products available
  20. Brake Master Cylinder 1 Products available
  21. Tachometers 1 Products available
  22. Analytical Instruments 1 Products available
  23. Communications Transmitters 1 Products available
  24. Food & Bakery Display Counter 1 Products available
  25. Calibration Services 1 Services available
  26. Level Controllers 1 Products available
  27. Sensors 1 Products available
  28. Switches And Switch Boxes 1 Products available
  29. Surveillance Systems 1 Products available
  30. Electric Counter 1 Products available
  31. Scientific Instruments 1 Products available
  32. Reverse Osmosis Plant Parts 1 Products available

Calibrating Machine

Leading Manufacturer, Supplier & Retailer of Infrared Black Body Calibrator BCAL 502, High Precision Pressure Calibrator, High Precision Pressure Calibrator PCAL 1300/0.350mbar, Pressure Calibrator PCAL 1300/700 and Infrared Black Body Calibrator BCAL 1502.

Infrared Black Body Calibrator BCAL 502

89,000 / Piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name SANSEL
  • Driven Type Electric
  • Condition New
  • MODEL BCAL : 502
  • Display : 4+4 digit 7 segment LED Display
  • Temperature Range : 50 to 500 °C
  • Resolution : 0.1°C
  • Stability : ± 0.2 °C
  • Uniformity in aperture area: ± 0.5°C@50°C, ± 1.7@250°C , ± 2.5@500°C
  • Heating Time (to Max) : 40 Minutes
  • Cooling  Time (to Max) : 40 Minutes to 100°C
  • Aperture area : 25 mm
  • Emissivity : 0.950
  • Power Supply : 230V AC ± 10% / 50Hz (Optional 110V AC)
  • Power Consumption : 500 VA
  • Instrument Weight : 4.5 kg

Additional Information:

Delivery Time : 28 days

View Complete Details

High Precision Pressure Calibrator

56,000 / Nos Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Operating Type Automatic
  • Pressure Low Pressure
  • Condition New
  • Brand Name SANSEL

Exact Pressure Measurement and Monitoring are Must in Applications Crucial to Operational Safety of Machinery and Industrial Installations. Regular Inspection of the Pressure gauges / sensor / transmitters / indicators Used in these Applications is Absolutely Essential for Economic and Technical - Safety Reasons and is Already Prescribed as Obligatory in Many Sectors

Description:

“SANSEL” PCAL 1300 / 2 is a Micro controller based precision pressure calibrators generates true reference pressure. Connect the gauge to be calibrated in the calibrator. Set the pressure using respective pump when stabilization.

Specifications:

  • Model : PCAL 1300 / 2 bar
  • Range (bar) : −0.9 to 2 bar
  • Pressure Media : Air
  • Pressure Pump : PVP – 01, 02
  • Display : 128 × 64 COG Graphic LCD with White LED Back Light
  • Instrument Port (at Pump) : 3/8” BSP Female
  • Test Port (at Pump) : ¼” BSP Female
  • Instrument Port : 3/8” BSP Male
  • Pump Dimension in mm (Approx.) : PVP – 01 (230 × 220 × 70 mm (H × W × D)), PVP – 02 (230 × 140 × 65 mm (L × B × H))
  • Resolution (bar) : 6 Digit User Selectable
  • Instrument Port (Extended) : ¼” BSP Male × 10 mm Long
  • Instrument Dimension : 100 × 100 × 55 (W × H × D) mm
  • Instrument Weight : 400 gms (Approx.)
  • Stability Time : 1 to 2 mins
  • Accuracy : ± 0.05% FS
  • Pressure Units (Selectable)* : bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mHO, ftHO, inHO, cmHO, mmHO
  • Pressure Zero : One Touch Zero Provided on Front Key
  • Pressure Peak : Maximum & Minimum with User Reset Option
  • Pressure Overflow : FS × 2 (Max.)
  • Pressure Burst : FS × 3 (Max.)
  • Temperature Measure : RTD – PT100 (2, 3, 4 Wire Selectable)
  • Temperature Range : −199.999 to 850.000
  • mA Measure : 0–24 mA (Scalable)
  • Display Scale : −99999 to 99999 Counts (for mA Measure Input)
  • Switch Test : Provided
  • Display Hold : One Touch Hold Provided on Front Key
  • Power Supply : 9 V DC ±5% / 600 mAh Rechargeable Battery with Battery Life 20 Hours without Backlight (or) 9 V DC Adapter / 230 V AC Supply Operated
  • Pump Weight (gms) (Approx.) : PVP – 01 (1.1 kg), PVP – 02 (750 gms)
  • PC Interface (Optional) : RS-485 (2 Wire) (Note: Connect to PC using USB to RS-485 Converter Supplied along with PC Software)
  • PC Software (Optional) : Windows Based Semi-Automatic Calibration Software (Optional)

Additional Information:

Delivery Time : 28 days

View Complete Details

High Precision Pressure Calibrator Pcal 1300/0.350mbar

45,000 / Nos Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Condition New
  • Brand Name SANSEL
  • Usage Liquid Pressure, Measuring Gas
  • Automatic Grade Automatic

Exact Pressure Measurement and Monitoring are Must in Applications Crucial to Operational Safety of Machinery and Industrial Installations. Regular Inspection of the Pressure gauges / sensor / transmitters / indicators Used in these Applications is Absolutely Essential for Economic and Technical - Safety Reasons and is Already Prescribed as Obligatory in Many Sectors

Description:

“SANSEL” PCAL 1300 / 0.350 mbar is a Micro controller based precision pressure calibrators generates true reference pressure. Connect the gauge to be calibrated in the calibrator. Set the pressure using respective pump when stabilization.

Specifications:

  • Model: Pcal 1300 / ± 350 mbar
  • Range (bar): ± 350 mbar
  • Pressure media: Air
  • Pressure pump: PVP – 01
  • Display: 128 × 64 COG Graphic LCD with White LED Backlight
  • Test Port (at pump): ¼” BSP Female
  • Instrument port (at pump): 3/8” BSP Female
  • Instrument Port: 3/8” BSP Male
  • Pump dimension in mm (Approx.): 230 × 220 × 70 mm (H × W × D)
  • Resolution (bar): 6 digit user selectable
  • Instrument dimension: 100 × 100 × 55 (W × H × D) mm
  • Instrument Weight: 400 gms (Approx.)
  • Stability time: 1 to 2 mins
  • Accuracy: ± 0.05% FS
  • Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, cmHO, mmHO
  • Pressure Zero: One touch zero provided on front key
  • Pressure Peak: Maximum & minimum with user reset option
  • Pressure overflow: FS X 2 (Max.)
  • Pressure burst: FS X 3 (Max.)
  • Temp.Measure: RTD - PT 100 (2, 3, 4, wire selectable)
  • Temp. Range: -199.999 to 850.000
  • mA Measure: 0-24 mA (scalable)
  • Display scale: -99999 to 99999 counts (for mA measure input)
  • Switch test: Provided
  • Display Hold: One touch hold provided on front key
  • Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
  • Pump Weight (gms) (Approx.): 1.1 kg
  • PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
  • PC Software (optional): Windows-based semi-automatic calibration software (optional)

Additional Information:

Delivery Time : 28 days

View Complete Details

Pressure Calibrator Pcal 1300/700

65,000 / Nos Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Pressure High Pressure
  • Condition New
  • Brand Name SANSEL

Exact Pressure Measurement and Monitoring are Must in Applications Crucial to Operational Safety of Machinery and Industrial Installations. Regular Inspection of the Pressure gauges / sensor / transmitters / indicators Used in these Applications is Absolutely Essential for Economic and Technical - Safety Reasons and is Already Prescribed as Obligatory in Many Sectors.

Description:

“SANSEL” PCAL 1300 / 700 is a Micro controller based precision pressure calibrators generates true reference pressure. Connect the gauge to be calibrated in the calibrator. Set the pressure using respective pump when stabilization.

Applications in

Energy - Production and Energy -Distribution Sectors

Glass, Ceramic, Semi Conductor Industries

Steel Material Processing Industries

Calibrators laboratories etc,

Specifications:

  • Model: Pcal 1300 / 700 bar
  • Range (bar): 0 to 700 bar
  • Pressure media: Oil & Water
  • Pressure pump: CT – 02
  • Display: 128 × 64 COG Graphic LCD with White LED Backlight
  • Resolution (bar): 6 digit user selectable
  • Instrument Port: ½” BSP Male x 10 mm long
  • Instrument dimension: 100 × 100 × 55 (W × H × D) mm
  • Instrument Weight: 400 gms (Approx.)
  • Stability time: 1 to 2 mins
  • Accuracy: ± 0.05% FS
  • Pressure units * (selectable): bar, mbar, MPa, kPa, Pa, PSI, kg/cm², inHg, cmHg, mmHg, mHO, ftHO, inHO, cmHO, mmHO
  • Pressure Zero: One touch zero provided on front key
  • Pressure Peak: Maximum & minimum with user reset option
  • Pressure overflow: FS X 2 (Max.)
  • Pressure burst: FS X 3 (Max.)
  • Temp.Measure: RTD - PT 100 (2, 3, 4, wire selectable)
  • Temp. Range: -199.999 to 850.000
  • mA Measure: 0-24 mA (scalable)
  • Display scale: -99999 to 99999 counts (for mA measure input)
  • Switch test: Provided
  • Display Hold: One touch hold provided on front key
  • Power Supply: 9V DC ±5% / 600 mAh Rechargeable battery with battery life 20 hours without backlight (or) 9V DC adapter / 230V AC supply operated
  • Pump Weight (Approx.): 14 kg
  • PC Interface (optional): RS-485 (2 wire) (Note: connect to PC using USB to RS 485 converter supplied along with PC software)
  • PC Software (optional): Windows-based semi-automatic calibration software (Optional)

Additional Information:

Delivery Time : 28 days

View Complete Details

Infrared Black Body Calibrator BCAL 1502

3.68 Lakh / Piece Get Latest Price
  • Min. Order (MOQ) 1 piece
  • Brand Name SANSEL
  • Driven Type Electric
  • Condition New

SANSEL Series BCAL 1502 is a Micro controller Based Precision Temperature Calibrators Generates True Reference Temperature. The Temperature Controller of the Calibrators Uses a Auto Tune PID Control Algorithm. Infra red thermometer & online pyrometer calibration is performed by comparison of the temperature measured by UUC and target temperature indicated by the calibrator or using standard pyrometer. Focus the Unit Under Calibration (UUC) to be Calibrate to the target point given in BCAL 1502. Set the Temperature from the Touch screen display. Both True and set Temperature can be read. When Stabilization Occurs, Simply Read the Temperature and re-Calibrate the UUC.

Specifications:

  • Model: BCAL 1502
  • Display: 4.3 inch True TFT LCD Display with Touch screen
  • Temperature Range: 500 to 1500 C
  • Resolution: 0.1C
  • Stability: 1C
  • Radial Uniformity: 1% of reading
  • Bath Temperature Control: Digital Temperature Controller with Auto Tune PID Algorithm
  • Temperature readout: C
  • Aperture area: 30mm
  • Emissivity: 0.950
  • Power supply: 230V AC 10% / 50Hz (Optional 110V AC)
  • Power Consumption: 4 KVA
  • Dimension (W*D*H) (Approx.): 580mm W x 450mm D x 390mm H
  • Instrument Weight (Approx): 45 kg

Additional Information:

Delivery Time : 28 days