Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Flow-Thru Conductivity Probe sensor

Listing ID #4146826

12,670 / Piece
Get Latest Price
  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

The HI3001 is a potentiometric sensor, utilizing four-ring technology to achieve accurate EC measurements. The four-ring technology allows for a wide range of measurement with a single probe as....
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • Year of Establishment 2005

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The HI3001 is a potentiometric sensor, utilizing four-ring technology to achieve accurate EC measurements. The four-ring technology allows for a wide range of measurement with a single probe as compared to amperometric two-pole probes that have a limited range and can suffer from polarization effects. The platinum sensors are protected by a PEI cover that can easily be removed for quick maintenance.

 

Internal Temperature Sensor

The integrated NTC temperature sensor of the HI3001 probe is crucial for accurate EC measurements. Since the temperature of a solution can drastically change the amount of conductance, obtaining a fast and stable temperature measurement allows for an accurately compensated EC reading.

 

Threaded Connection

The ½” front NPT threaded connection of the HI3001 allows for flow-thru mounting, while the ¾” back threads allow for submersion or pipe mounting without the need for additional hardware.

 

PVDF Body

Polyvinylidene fluoride (PVDF) is a plastic that is resistant to most chemicals and solvents. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

 

Multiple Cable Lengths

The HI3001D models feature a DIN connector for use with Hanna’s HI99XX series of wall-mounted controllers, along with varying lengths of cable.

 

HI3001D comes with a DIN connector and 3 meters (9.9’) of cable attached.

HI3001D/5 comes with a DIN connector and 5 meters (16.4’) of cable attached.

HI3001D/10 comes with a DIN connector and 10 meters (32.8’) of cable attached.


Company Details close-icon

Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2005
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Flow-Thru Conductivity Probe sensor?

Quantity
Seller Contact Details
  • Seller hanna Equipments (india) pvt ltd
  • Address Perungudi, Chennai, Tamil Nadu
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Flow-Thru Conductivity Probe sensor at Rs 12,670 / Piece in Chennai - ID: 4146826
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Flow-Thru Conductivity Probe sensor

Listing ID #4146826

12,670 / Piece
Get Latest Price
  • Supply Type Manufacturer, Exporter, Supplier
Preferred Buyer From : All over the world

The HI3001 is a potentiometric sensor, utilizing four-ring technology to achieve accurate EC measurements. The four-ring technology allows for a wide range of measurement with a single probe as....
View More Details
Send Enquiry

Company Information

  • Member Since 16 Years
  • Nature of Business Retailer
  • Year of Establishment 2005

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The HI3001 is a potentiometric sensor, utilizing four-ring technology to achieve accurate EC measurements. The four-ring technology allows for a wide range of measurement with a single probe as compared to amperometric two-pole probes that have a limited range and can suffer from polarization effects. The platinum sensors are protected by a PEI cover that can easily be removed for quick maintenance.

 

Internal Temperature Sensor

The integrated NTC temperature sensor of the HI3001 probe is crucial for accurate EC measurements. Since the temperature of a solution can drastically change the amount of conductance, obtaining a fast and stable temperature measurement allows for an accurately compensated EC reading.

 

Threaded Connection

The ½” front NPT threaded connection of the HI3001 allows for flow-thru mounting, while the ¾” back threads allow for submersion or pipe mounting without the need for additional hardware.

 

PVDF Body

Polyvinylidene fluoride (PVDF) is a plastic that is resistant to most chemicals and solvents. It has high abrasion resistance, mechanical strength, and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.

 

Multiple Cable Lengths

The HI3001D models feature a DIN connector for use with Hanna’s HI99XX series of wall-mounted controllers, along with varying lengths of cable.

 

HI3001D comes with a DIN connector and 3 meters (9.9’) of cable attached.

HI3001D/5 comes with a DIN connector and 5 meters (16.4’) of cable attached.

HI3001D/10 comes with a DIN connector and 10 meters (32.8’) of cable attached.


Company Details close-icon

Hanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.
The HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g/L, ppb, μg/L, mg/mL, M, mol/L, mmol/L, % w/v, user defined) and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 1010.
Pressing the "AutoHold" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An “out of calibration range” warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.
The log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.
Access help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.
The high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.
The compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 20 - 50
  • Year of Establishment 2005
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Flow-Thru Conductivity Probe sensor?

Quantity
Seller Contact Details
  • Seller hanna Equipments (india) pvt ltd
  • Address Perungudi, Chennai, Tamil Nadu
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice