Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Single Phase Isolation Transformer

Listing ID #1089155

  • Harmonic K-RatingK-4, K-7, K-13, or K-20 rated in accordance with : K = Σ Ih(pu)2 h2
  • Efficiency97% typical.
  • Basic Impulse levelNo less than 10,000 Volts.
  • Output Impedance3-4 % typical.
  • Supply Type Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 11 Years
  • Nature of Business Retailer
  • GST No. 29ACTPY5067E1ZR

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Flux density ≤ 15k gauss.
  • Output Impedance 3-4 % typical.
  • Harmonic K-Rating K-4, K-7, K-13, or K-20 rated in accordance with : K = Σ Ih(pu)2 h2
  • MTBF ≥ 200,000 hours.
  • Transformer Steel Grain oriented, M6 grade, silicon steel.
  • Basic Impulse level No less than 10,000 Volts.
  • Nominal AC Output Voltage Ratings 120/240VAC or 120/208/240 VAC, single phase, 60 hertz.
  • Efficiency 97% typical.

Single Phase Isolation Transformer is available in variegated technical specifications. We hold expertise in manufacturing, exporting and supplying quality transformer that are used on all systems that require grounding on the load. Our isolation transformer is a copper wound, multi-shielded, single phase, K-factor rated, high efficiency, power conditioning isolation transformer. It is duty rated and belongs 600 volt class. This isolation transformer supports harmonic rich non-linear loads while maintaining safe operating temperatures. Easy to install and maintain, this isolation transformer is reckoned for its high quality, efficiency and reliability.
Standards :

  • The power conditioning system is designed in accordance with applicable portions of the following standards:
  • American National Standards Institute (ANSI C57.110 & C62.41-1991)
  • Institute of Electrical and Electronic Engineers (IEEE 519-1992)
  • National Fire Protection Association (NFPA) 70, National Electrical Code (NEC)
  • Federal Information Processing Standards Publication 94 (FIPS Pub 94)
  • UL Listed to Standard 1561
  • C-UL listed to CSA Standard C22.2, No. 47-M90

 
Input Specifications :

  • Nominal AC input voltage ratings: 480 VAC, 240 VAC or 208 VAC, 1 phase, with sufficient margin to sustain a constant input of +10% without saturation.
  • The nominal operating frequency: 60 hertz + 3 hertz.
  • The power conditioning system’s primary is configured single phase, two wire, plus ground, and includes full capacity taps at 2½ % increments, two (2) above and four (4) below the nominal voltage tap.
  • Energizing inrush current will not exceed 10 times the full load input current for ½ cycle.


Performance Specifications :

  • Load Regulation : Maintained within +2.5% or less of nominal, from no load to full load.
  • Overload : 500% for 10 seconds, and 1,000% for one cycle.
  • THD : ≤ 1% added to the output voltage waveform under a linear load.
  • Output Voltage : Sinusoidal with no flat topping when high crest factor (3.0 : 1), non-linear loads are present at the output.
  • Audible Noise Measured at 1 Meter from the Unit : ≤ 50dBA
  • Electrostatic Shielding : Incorporates two, or an optional three, solid copper foil electrostatic shields which minimize inner winding capacitance, transients, and noise coupling between primary and secondary windings.
  • Common Mode Noise Attenuation : 126 dB with two shields, or 146dB with optional three shields.
  • Transverse Mode Noise Attenuation : 3 dB down at 10kHz, decaying 20 dB per decade.
  • Optional TVSS : Incorporates a fused (with front panel mounted, blown fuse lamp indicator), secondary connected, 3 mode spike suppression network. The TVSS is comprised of high energy metal oxide varistors with less than a 5 nanosecond response time and a maximum peak current handling capability of 40,000 amps (8x20μsec) per mode.
  • Thesuppression network system will remain functional when subjected to ANSI/IEEE C62.41 Category B-3 waveforms.
  • The spike suppression network increases the transverse mode noise attenuation to 3 dB down at 10kHz, decaying 40 dB per decade.

 

Main Transformer :

  • Transformer Windings : All copper conductor construction, with separate primary and secondary, isolated windings.
  • The transformer conforms to NEC article 250, that specifies a separately derived power source. The neutral conductor is sized for 200% of the ampacity of the phase conductor.
    Terminals are provided for isolated single phase output conductors, neutral conductor and ground.
  • All leads, wires and terminals are labeled to correspond with the circuit wiring diagram.
    • Basic Impulse level : No less than 10,000 Volts.
    • MTBF : ≥ 200,000 hours.
    • Transformer Steel : Grain oriented, M6 grade, silicon steel.
    • Flux density : ≤ 15k gauss.
    • Core losses : ≤ 0.6% of the KVA rating.
    • Insulation : Class N, 200OC with a maximum temperature rise of 115OC above ambient, not exceeding 130OC under nonlinear
    • loading per UL 1561.
    • Cooling : Natural convection.

 

Cabinet :

  • Enclosure : NEMA type 1, floor mounted, and indoor enclosure.
  • Construction : Cabinets are manufactured from 14 gauge steel with base sub-structure suitable for fork lifting.
  • Paint : Baked on, powder coat paint finish with proper pre-treatment.
  • Provisions exist to hardwire input and output power connections to terminals located within the unit enclosure. Input and output conduit landing locations are available on the rear of the unit enclosure.

 

Environment :

  • Operating Temperature Range : -20OC to +40OC.
  • Humidity : 0 to 95% non-condensing.
  • Altitude : Up to 5000 feet above sea level without de-rating.

 

Warranty : Manufacturer guarantees equipment to be free from defects in material and workmanship for a period of 2 years following shipment from the factory


Output Power Ratings, Dimensions And Weights

Continuous kVA Cabinet Dimensions (in) Weight (lbs)
5 14.75”W x 21”D x 24”H 289
8 14.75”W x 21”D x 24”H 330
10 21.5”W x 29”D x 30”H 380
15 21.5”W x 29”D x 30”H 415
20 21.5”W x 29”D x 30”H 491
25 21.5”W x 29”D x 30”H 554

 

Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Single Phase Isolation Transformer?

Quantity
Seller Contact Details
  • Seller VBK Power Technologies
  • Address Nagarbhavi, Bangalore, Karnataka
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Single Phase Isolation Transformer at Best Price in Bangalore - ID: 1089155
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Single Phase Isolation Transformer

Listing ID #1089155

  • Nominal AC Output Voltage Ratings120/240VAC or 120/208/240 VAC, single phase, 60 hertz.
  • Output Impedance3-4 % typical.
  • Basic Impulse levelNo less than 10,000 Volts.
  • Efficiency97% typical.
  • Supply Type Supplier
Preferred Buyer From : All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 11 Years
  • Nature of Business Retailer
  • GST No. 29ACTPY5067E1ZR

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Efficiency 97% typical.
  • MTBF ≥ 200,000 hours.
  • Nominal AC Output Voltage Ratings 120/240VAC or 120/208/240 VAC, single phase, 60 hertz.
  • Transformer Steel Grain oriented, M6 grade, silicon steel.
  • Flux density ≤ 15k gauss.
  • Harmonic K-Rating K-4, K-7, K-13, or K-20 rated in accordance with : K = Σ Ih(pu)2 h2
  • Basic Impulse level No less than 10,000 Volts.
  • Output Impedance 3-4 % typical.

Single Phase Isolation Transformer is available in variegated technical specifications. We hold expertise in manufacturing, exporting and supplying quality transformer that are used on all systems that require grounding on the load. Our isolation transformer is a copper wound, multi-shielded, single phase, K-factor rated, high efficiency, power conditioning isolation transformer. It is duty rated and belongs 600 volt class. This isolation transformer supports harmonic rich non-linear loads while maintaining safe operating temperatures. Easy to install and maintain, this isolation transformer is reckoned for its high quality, efficiency and reliability.
Standards :

  • The power conditioning system is designed in accordance with applicable portions of the following standards:
  • American National Standards Institute (ANSI C57.110 & C62.41-1991)
  • Institute of Electrical and Electronic Engineers (IEEE 519-1992)
  • National Fire Protection Association (NFPA) 70, National Electrical Code (NEC)
  • Federal Information Processing Standards Publication 94 (FIPS Pub 94)
  • UL Listed to Standard 1561
  • C-UL listed to CSA Standard C22.2, No. 47-M90

 
Input Specifications :

  • Nominal AC input voltage ratings: 480 VAC, 240 VAC or 208 VAC, 1 phase, with sufficient margin to sustain a constant input of +10% without saturation.
  • The nominal operating frequency: 60 hertz + 3 hertz.
  • The power conditioning system’s primary is configured single phase, two wire, plus ground, and includes full capacity taps at 2½ % increments, two (2) above and four (4) below the nominal voltage tap.
  • Energizing inrush current will not exceed 10 times the full load input current for ½ cycle.


Performance Specifications :

  • Load Regulation : Maintained within +2.5% or less of nominal, from no load to full load.
  • Overload : 500% for 10 seconds, and 1,000% for one cycle.
  • THD : ≤ 1% added to the output voltage waveform under a linear load.
  • Output Voltage : Sinusoidal with no flat topping when high crest factor (3.0 : 1), non-linear loads are present at the output.
  • Audible Noise Measured at 1 Meter from the Unit : ≤ 50dBA
  • Electrostatic Shielding : Incorporates two, or an optional three, solid copper foil electrostatic shields which minimize inner winding capacitance, transients, and noise coupling between primary and secondary windings.
  • Common Mode Noise Attenuation : 126 dB with two shields, or 146dB with optional three shields.
  • Transverse Mode Noise Attenuation : 3 dB down at 10kHz, decaying 20 dB per decade.
  • Optional TVSS : Incorporates a fused (with front panel mounted, blown fuse lamp indicator), secondary connected, 3 mode spike suppression network. The TVSS is comprised of high energy metal oxide varistors with less than a 5 nanosecond response time and a maximum peak current handling capability of 40,000 amps (8x20μsec) per mode.
  • Thesuppression network system will remain functional when subjected to ANSI/IEEE C62.41 Category B-3 waveforms.
  • The spike suppression network increases the transverse mode noise attenuation to 3 dB down at 10kHz, decaying 40 dB per decade.

 

Main Transformer :

  • Transformer Windings : All copper conductor construction, with separate primary and secondary, isolated windings.
  • The transformer conforms to NEC article 250, that specifies a separately derived power source. The neutral conductor is sized for 200% of the ampacity of the phase conductor.
    Terminals are provided for isolated single phase output conductors, neutral conductor and ground.
  • All leads, wires and terminals are labeled to correspond with the circuit wiring diagram.
    • Basic Impulse level : No less than 10,000 Volts.
    • MTBF : ≥ 200,000 hours.
    • Transformer Steel : Grain oriented, M6 grade, silicon steel.
    • Flux density : ≤ 15k gauss.
    • Core losses : ≤ 0.6% of the KVA rating.
    • Insulation : Class N, 200OC with a maximum temperature rise of 115OC above ambient, not exceeding 130OC under nonlinear
    • loading per UL 1561.
    • Cooling : Natural convection.

 

Cabinet :

  • Enclosure : NEMA type 1, floor mounted, and indoor enclosure.
  • Construction : Cabinets are manufactured from 14 gauge steel with base sub-structure suitable for fork lifting.
  • Paint : Baked on, powder coat paint finish with proper pre-treatment.
  • Provisions exist to hardwire input and output power connections to terminals located within the unit enclosure. Input and output conduit landing locations are available on the rear of the unit enclosure.

 

Environment :

  • Operating Temperature Range : -20OC to +40OC.
  • Humidity : 0 to 95% non-condensing.
  • Altitude : Up to 5000 feet above sea level without de-rating.

 

Warranty : Manufacturer guarantees equipment to be free from defects in material and workmanship for a period of 2 years following shipment from the factory


Output Power Ratings, Dimensions And Weights

Continuous kVA Cabinet Dimensions (in) Weight (lbs)
5 14.75”W x 21”D x 24”H 289
8 14.75”W x 21”D x 24”H 330
10 21.5”W x 29”D x 30”H 380
15 21.5”W x 29”D x 30”H 415
20 21.5”W x 29”D x 30”H 491
25 21.5”W x 29”D x 30”H 554

 

Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Single Phase Isolation Transformer?

Quantity
Seller Contact Details
  • Seller VBK Power Technologies
  • Address Nagarbhavi, Bangalore, Karnataka
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice