Listing ID #1922064
Company Information
Ask for more detail from the seller
Contact SupplierWe are instrumental in offering our clients highly functional Solar String Combiner Boxes. This Solar String Combiner Boxes, which we offer, are fabricated with the use of latest technology and are suitable for different Solar Power applications. Our Combiner Boxes is properly tested by the experts under strict industry norms to guarantee flawless functioning and durability. Also known as Array Junction Boxes (AJB), these Solar String Combiner Boxes have PV combiner boxes, basically collect DC power from PV strings with blocking diodes on each string for protecting panels from reverse current flow. The collected power is then transferred to power inverter.
Also known as Array Junction Boxes (AJB), these Solar String Combiner Boxes have PV combiner boxes, basically collect DC power from PV strings with blocking diodes on each string for protecting panels from reverse current flow. The collected power is then transferred to power inverter.
GEESYS Solar Junction Boxes
Introduction
Features
Main Functional Features of The Main Junction Box
Features :
Array Junction Box (AJB)
Parameters | Array configuration | String configuration |
---|---|---|
Model | GETCETINV | GETSTRINV |
Maximum DC Input Range | 1000V | 1000V |
No of DC Inputs | 2 - 16 | 2 - 24 |
No of DC Outputs | 1 | 1 - 8 |
Number of Terminal Blocks | 4 - 34 | 4 - 48 |
Reverse Blocking Diode, No's | 2 - 12 | 2 - 24 |
Maximum Input Fuse* Rating, A | 3/5/10/12/15/20/30 | 12/16/32/40/63 |
Maximum string current per fuse holder with all string fuse** | Reduction factor 0.55 | Reduction factor 0.55 |
Maximum DC Current, A | 100 | 192 |
Maximum Continuous Current, A | 160 | 240 |
Isolator/MCB*, A | 16/32/40/63 | 16/32/40/63 |
Maximum Voltage, VDC | 600/1000 | 600/1000 |
+Ve Input Wire Size,1C x sqmm | 2.5 - 10 | 4 - 25 |
-Ve Input Wire Size, 1C x sqmm | 2.5 - 10 | 4 - 25 |
MOV | 110/680V | 110/680V |
Surge Protection Device (SPD)* | 600/1000V, Class II | 600/1000V, Class II |
Operating Temperature | -25 to 55 | -25 to 55 |
Enclosure Type | PS/PC* | PS/PC* |
Protection Type/Protection Class | IP65 | IP65 |
Connectors* @ Output | MC4/MC3 | MC4/MC3 |
Cable gland clamping range, mm | 12 - 32 | 12 - 32 |
Wall mounting | Yes | Yes |
Bus Bar* | Yes | Yes |
Operating conditions | Temp : -20 to +55 Deg. C ; RH :95% non cond | |
Type of Protections(As per Clients requirement) | Short-Circuit, Surge | Short-Circuit, Surge |
International standards followed | IEC 60364 | IEC 60364 |
Disconnection switch | Optional | Optional |
Design Life | 25 years + |
Main Junction Box (MJB)
Parameters | Array configuration | String configuration |
---|---|---|
Model | GETCETINV | GETSTRINV |
Maximum DC Input Range | 1000V | 1000V |
No of DC Inputs | 2 - 16 | 2 - 24 |
No of DC Outputs | 1 | 1 - 8 |
Number of Terminal Blocks | 4 - 34 | 4 - 48 |
Reverse Blocking Diode, No | 2 - 12 | 2 - 24 |
Maximum Input Fuse* Rating, A | 3/5/10/12/15/20/30 | 12/16/32/40/63 |
Maximum string current per fuse holder with all string fuse | Reduction factor 0.55 | Reduction factor 0.55 |
Maximum DC Current, A | 100 | 192 |
Maximum Continuous Current, A | 160 | 240 |
Isolator/MCB*, A | 16/32/40/63 | 16/32/40/63 |
Maximum Voltage, VDC | 600/1000 | 600/1000 |
+Ve Input Wire Size,1C x sqmm | 2.5 - 10 | 4 - 25 |
-Ve Input Wire Size, 1C x sqmm | 2.5 - 10 | 4 - 25 |
MOV | 110/680V | 110/680V |
Surge Protection Device (SPD) | 600/1000V, Class II | 600/1000V, Class II |
Operating Temperature | -25 to 55 | -25 to 55 |
Enclosure Type | PS/PC* | PS/PC* |
Protection Type/Protection Class | IP65 | IP65 |
Connectors* @ Output | MC4/MC3 | MC4/MC3 |
Cable gland clamping range, mm | 12 - 32 | 12 - 32 |
Wall mounting | Yes | Yes |
Bus Bar* | Yes | Yes |
Operating conditions | Temp : -20 to +55 Deg. C ; RH : 0 95% non cond | |
Type of Protections(As per Clients requirement) | Short-Circuit, Surge | Short-Circuit, Surge |
International standards followed | IEC 60364 | IEC 60364 |
Disconnection switch | Optional | Optional |
Design Life | 25 years + |