Leading Manufacturer, Supplier & Retailer of Oxygen Gas Sensor Transmitter, Wall Mounted Ethylene Gas Sensor Transmitter, Lel Gas Sensor Transmitter, ATS-109TD Oxygen Gas Sensor Transmitter and Ethylene Gas Sensor Transmitter.
FeatureNon Conductive Liquid, Reservoirs Hoppers, Safety Interlocks, Suitable For Sensing Level, Visual Alarm System
TheATS-109TD Oxygen Gas Sensor Transmitteron 24 VDC power and features LED alarm indicators, 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.
Features:
Detection of combustible, toxic Gases and Oxygen
Non-intrusive calibration
Smart sensors
Programmable relays
2-wire, 3-wire, ModBus
Flame proof Junction Box
Available in stainless steel
Available in wireless version
Flame proof Junction Box Approval CCOE CMRI
Specification:
Principle
Electrochemical, Solid State Semiconductor and Catalytic
The LEL (Lower Explosive Limit) Gas Sensor Transmitter is used to detect the presence of flammable gases like methane, propane, or hydrogen in the air. It continuously monitors gas concentration levels and alerts if the gas reaches a dangerous level. It uses a catalytic bead or infrared sensor, provides 420 mA or RS485 output, and can be connected to control panels or alarms. Suitable for industrial plants, gas storage areas, and chemical factories, this device ensures safety by helping prevent gas explosions.
LEL stands for Lower Explosive Limit. It is the minimum concentration of a flammable gas in air that can ignite.
It can detect flammable gases such as methane (CH), propane, butane, hydrogen, and LPG.
It uses a catalytic bead or infrared sensor to measure the concentration of combustible gases and sends real-time signals to control systems
Standard outputs include 420 mA analog and RS485 Modbus digital for easy integration with SCADA or PLC systems.
Yes, flameproof/ex-proof models are available for Zone 1 and Zone 2 classified areas.
The transmitter can be connected to external audible/visual alarms through relay output or gas controllers.
It is recommended to calibrate every 6 to 12 months depending on usage and environmental conditions.
TheATS-109TD Oxygen Gas Sensor Transmitteron 24 VDC power and features LED alarm indicators, 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.
Features:
Detection of combustible, toxic Gases and Oxygen
Non-intrusive calibration
Smart sensors
Programmable relays
2-wire, 3-wire, ModBus
Flame proof Junction Box
Available in stainless steel
Available in wireless version
Flame proof Junction Box Approval CCOE CMRI
Specification:
Principle
Electrochemical, Solid State Semiconductor and Catalytic
TheCH Gas Detection Systemis designed for thecontinuous monitoring and detection of Methane (CH) gasleaks or buildup in industrial, commercial, and hazardous environments. Methane being ahighly flammable gas, accurate and real-time detection is critical forexplosion prevention, process safety, andregulatory compliance.
Chlorine Gas Tranmsitterwith without Display operates on 24 VDC power and 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.
rn
A Chlorine Gas Transmitter** is a fixed-type gas monitoring device designed to detect and measure the concentration of chlorine gas (Cl) in the ambient air. It provides real-time detection and alerting to ensure safety in environments where chlorine is used or stored.
rn
Most chlorine gas transmitters use electrochemical sensors, which produce an electrical current proportional to the Cl gas concentration when the gas comes in contact with the sensor\'s electrodes.
Sulfur Dioxide Gas Sensor Tranmsitterwith without Display operates on 24 VDC power and 4-20 mA output and optional alarm relay board. This sensor/transmitter can be connected to various applied controllers or computer-based instrumentation, such as PLC or similar instrumentation.
FeatureAccuracy, Alarm System, Durable, Easy To Use, Eco Friendly
Display TypeDigital
Gas TypeLPG Gas
SensorCatalytic
SamplingDiffusion • Power Supply : 24 V DC from control unit
HousingFlame proof
Operating Temp-20 to +50 Deg C
Resolution1% LEL
Model No.ATS 109TD
MountingWall mounting, 2" Pipe (U clamps will be provided)
The LPG Gas Transmitter** is a robust, fixed gas detection device designed to detect the presence of LPG (Propane/Butane mixtures) in industrial or commercial environments. It converts gas concentration into an electrical signal, which can be monitored via control panels or SCADA systems for safety alarms, automatic shut-off, or ventilation activation.
rnrn Key Specifications:rn
rn
rn
rnrn
ParameterDetails
rnrnrn
rn
Gas Detected
rn
LPG (Propane/Butane)
rn
rn
rn
Detection Principle
rn
Catalytic / Semiconductor / Infrared (NDIR)
rn
rn
rn
Measurement Range
rn
0100% LEL (Lower Explosive Limit)
rn
rn
rn
Accuracy
rn
3% of full scale
rn
rn
rn
Response Time (T90)
rn
30 seconds
rn
rn
rn
Output Signal
rn
420 mA / RS-485 Modbus
rn
rn
rn
Power Supply
rn
1230V DC
rn
rn
rn
Alarm Levels
rn
Configurable low & high alarm thresholds
rn
rn
rn
Enclosure
rn
IP65 / IP66 (weatherproof, optionally flameproof)
rn
rn
rn
Operating Temp.
rn
-20C to +60C
rn
rn
rn
Mounting
rn
Wall mount (indoor or outdoor)
rn
rn
rn
Display (optional)
rn
LED or LCD with real-time gas concentration
rn
rnrn
rnrn
rn
rnrn Key Features:rn
rn
rn
Early detection of LPG gas leaks
rn
rn
rn
Continuous real-time gas monitoring
rn
rn
rn
Compatible with control panels, PLCs, and SCADA systems
rn
rn
rn
Low maintenance with long-life sensors
rn
rn
rn
Rugged and flameproof housing available for hazardous zones
rn
rn
rn
Supports RS-485 Modbus communication (optional)
rn
rn
rn
Relay outputs available for direct control (fan, alarm, shutoff)
The Ammonia Gas Sensor Transmitter (without display) is a fixed-installation device used for continuous detection of NH gas leaks or concentration levels in industrial environments. It is designed for integration into control systems (PLC/SCADA) and is ideal for applications where local display is not required, ensuring cost-efficiency and minimal maintenance. Technical Specifications:Parameter DetailsGas Detected Ammonia (NH)Detection Range 050 / 0100 / 0500 ppm (customizable)Sensor Type Electrochemical / Semiconductor / Infrared (as per range)Response Time (T90) 30 secondsOutput Signal 420 mA / RS485 Modbus / Relay (optional)Display Not included (designed for remote monitoring)Power Supply 1230 VDCEnclosure Weatherproof IP65 / Flameproof (optional)Mounting Wall or duct mountingCalibration Manual with span gas, field serviceableOperating Temp Range -10C to +55CHumidity Range 095% RH (non-condensing)Sensor Life 1824 months typical
Key Features:No display suitable for remote or integrated monitoring Reliable detection of low- and mid-range NH gas concentrations Supports analog and digital outputs for system integration Compact and weatherproof enclosure for industrial use Field-replaceable sensor with easy calibration Applications:Chemical and fertilizer manufacturing
Cold storage & refrigeration systems Livestock and poultry farms Industrial safety & ventilation control Water and wastewater treatment plants
Applied Techno Systems manufactures a wide range ofCO Gas TransmitterwithThe sensing and reference elements are self-compensating for temperature integrity. The industry standard 4 -20 mA analog output provides remote alarm, fault and calibration signals.
An Ammonia Gas Transmitter is a fixed gas detection device used to continuously monitor NH gas levels in ambient air or confined environments. It converts the gas concentration into a proportional 420 mA / RS485 signal, ideal for integration into BMS, DCS, PLC, or SCADA systems.
Technical Specifications:
ParameterDetails
Gas Detected
Ammonia (NH)
Measurement Range
050 / 0100 / 0500 ppm (customizable)
Sensor Type
Electrochemical / Infrared (optional)
Output Signal
420 mA / RS-485 Modbus
Accuracy
2% of full scale
Response Time (T90)
30 seconds
Power Supply
1230V DC
Display (optional)
Digital LCD/OLED
Alarm
Optional visual & audible
Operating Temp
-10C to +55C
Enclosure
IP65 weatherproof, optionally flameproof
Mounting Type
Wall or duct mount
Calibration
Manual / Auto via test gas
Features:
Continuous monitoring of Ammonia gas
Real-time output for process control
Optional alarm triggers on high NH levels
Rugged design for industrial use
Field-replaceable sensor and easy calibration
Available in flameproof housing for hazardous zones
The Online Ammonia Gas Sensor Transmitter is a fixed-installation device designed to continuously monitor NH gas concentrations in real-time. Suitable for industrial safety, environmental compliance, and process control applications, it provides analog and digital output signals for easy integration with control systems like SCADA, PLC, or DCS.
Technical Specifications:
ParameterDetails
Gas Detected
Ammonia (NH)
Measurement Range
050 / 0100 / 0500 ppm (customizable)
Sensor Type
Electrochemical / PID (for trace levels)
Output Signal
420 mA / RS485 Modbus RTU / Relay (optional)
Response Time (T90)
30 seconds
Accuracy
2% of full scale
Power Supply
1230 VDC or 220 VAC (with adapter)
Display (Optional)
Digital OLED or LCD
Alarm System
Programmable visual + audible (optional)
Enclosure Protection
IP65 / IP66 / Flameproof (Zone 1 & 2 available)
Operating Temperature
-20C to +55C
Mounting Type
Wall / Pipe Mount
Sensor Life
1824 months (field replaceable)
Key Features:
24x7 online NH gas monitoring
Standard industrial output signals (420 mA / Modbus)
Hydrogen Gas Sensor Transmitterincorporates a pellistor or catalytic bead sensor. This sensor consists of a matched pair of elements, one active and the other for compensation. When in contact with a combustible hydrocarbon or solvent causes the gas or vapor to "burn" or oxidize at concentrations below the Lower Explosive Limit (LEL). This oxidization process raises the temperature of the active bead and increases the resistance of the internal wire coil. The second bead does not have the catalytic coating and provides compensation for environmental conditions including temperature and humidity. When these elements are connected to the circuit, a useable signal is produced that is proportional to the gas concentration . Applications :
Number Of FlowerGas Transmitter, Detector, Transmitter
Country of Origin230V AC
ApplicationMonitoring
ConditionNew
MaterialMetal
Brand NameApplied Techno Engineers Pvt. Ltd.
SamplingDiffusion
DisplayLED
Digital OutputRelay for alarm
Analog Output4-20mA
Working Temp5 to 55 Deg C
Supply Voltage24V DC
Flame Proof Oxygen Gas Sensor Tranamitter- With LED Display Power Supply : 24V DC or 230V AC ( As per requirments). Range : 0-25% V/V/30%V/V. Output : 4-20 mA. Relay Output (Optional). Buzzer ( Optional).
Specification:
Response Time: < 5 Seconds
Zero drift: 0.2% FS
Accuracy : 2%
Operating Voltage: 22-30 V DC or 230VAC
Operating Temp: 0-50 C
Display: Inbuilt 0.5 " LCD
Output : 4-20 mA Linear , Relay, / 0-1 Volts DC (V) / RS 232/ RS485 2 wire (Electochemical Sensor based.
Being a versatile entity in this domain, we are instrumental in manufacturing, exporting and supplying the top grade range ofCombustible Gas Transmitter.Mainly installed at industrial areas, this transmitter is used to detect even traces of gas leakage. With aid of ultra modern techniques, the provided transmitter is manufactured using pristine grade components. Our patrons can avail thisCombustible Gas Transmitterfrom us at economical prices.
Key Points:
Easy to install
Sturdy design
Ruggedness
Low maintenance
Technical Specification
Principle
Electrochemical, Solid State Semiconductor and Catalytic