Our product range contains a wide range of Ammonia Gas Analyser, Online Stack SPM Analyzer, Portable Oxygen Gas Leak Meter, Portable Oxygen Gas Analyser and Portable Head Space Oxygen Gas Analyzer
Ammonia Gas Analysercontinuously monitors the concentration of Ammonia in PPM and other gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance.
Special gas sample Conditioning systems are used to clean and dry the gas sample for accurate and High performance operation. An Internal Pump draw gas sample into the sensor through a dust particle filter from an intake which can be located at distance up to 40 meter form the monitor.
The Sensor and Electronic component are housed in tough aluminum housing.
Applications:
Metal heat Treatment
Boiler Systems
Cement & Lime Manufacturer
Combustion Process
Hydrogen Cooled Alternators & Turbine
Gasification & Syngas
Pulp & Paper
Metal Heat Treatment Plant
Laboratories & Institutions
Flame Treatment Process & Chemical Industries
Petrochemical & Pharmaceutical Industries
Features:
Microcontroller based embedded intelligent instruments
Continuous Monitoring of CO2 , CH4, CO, O2, SO2, NOX (NO NO2), H2, H2S, N2
Duel wavelength Infra red sensor for Long terms accuracy and stability
Long Life Electro chemical sensor
Six Gas Analysis in Single Analyzer
Multi Parameter Single 320 X 240 Graphics LCD Display
Self diagnostic & Self integrity check
RS 232/RS 485 and USB Computer Interface
Excellent low level capability for NOX and SO2 Measurement
For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
Analog 4-20mA output for each gas
Software solutions for Gas Analysis
Web Based Real time data transfer with GSM/GPRS Technology
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Low Battery Consumption, Mercury-free
Country of OriginIndia
Online Stack SPM AnalyzerManufacture in Mumbai.Process Trend Monitor and Multi -Purpose Dust Alarm with Display A Real time Continuous indicative dust monitor with logging & alarm capability. Low Cost Solution to Monitoring Requirements. Application: The stack Guard is used in most situations where the actual or potential presence of particulates creates an indicative monitoring requirement & also where higher cost of a quantative monitor is not justified. Filter Failure Alarms., Process Control Monitor, Cogeneration Power Plants, Ferrous &Non Ferrous metal Processing Unit, cement Plants & Silos, Petrochemical, Pharma , Boilers & Incinerators Paper Plants etc.
Specification
Measurement Technique: Tribo - Electric Charger transfer
Sensitivity: Adjustable over a wide dynamic range
Operating Temp (Ambient): -15 to 50 deg C
Operating Temp (Gas): -15 to 250 deg C ("T" Model up to 700 deg C)
Ranges: 1-1, 000mg/m3
Response Time: Instantaneous
Installation:Duct Width: 25 mm to 2.2m
Positioning: 90 deg C to Duct wall
Communications path Length: up to 1, 000 meters
Socket : Single 1 flat Flanged fitting
Probe Construction: 316 Grade Stainless Steel
Sensor Length : 25, 100 or 200 mm ( or Customized)
Resolution0.01, 0.1 or 1 PPM, %V/V, % LEL as applicable
Accuracy0.5%
Repeatability+/- 2 %
Response Time< 30 seconds at 95 % variation
AlarmsLow & High Visual and Audible
The Portable Gas Monitor is a compact and durable gas monitoring device designed for industrial use. Its dimensions of 115 X 180 X 60 mm and lightweight design of 300 grams make it highly portable and easy to use. Made with ABS plastic, the device is built to withstand harsh industrial conditions. The device is powered by electricity and can operate in temperatures ranging from -30 to 55 degrees Celsius, ensuring its functionality in various environments. The device has a voltage of 220 volts and comes in a white color for easy visibility. With its accurate monitoring capabilities, this device can detect the presence of gas in the air, providing an essential safety feature for users.
rnrn
rnFAQs of Portable Gas Monitor:rnrn
rnQ: What type of gas can the Portable Gas Monitor detect?rnA:The Portable Gas Monitor can detect a wide range of gases, including methane, carbon monoxide, hydrogen, and more. rnQ: Is the Portable Gas Monitor easy to use?rnA:Yes, the device is extremely user-friendly and can be operated by anyone, regardless of their technical expertise. rnQ: How long does the devices battery last?rnA:The device is powered by electricity, so it does not require batteries. rnQ: What is the range of the devices voltage?rnA:The Portable Gas Monitor operates on a voltage of 220V. rnQ: Is the Portable Gas Monitor suitable for outdoor use?rnA:Yes, the device is designed for industrial use in various environments, including indoor and outdoor settings.
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Light Weight, Low Battery Consumption
Weight0-5kg
Detected gasO2
Range0-25% V/V
Accuracy+/-2%
Display128 x64 Graphics Display
SamplingAuto Suction Through Inbuilt Pump
Power SupplyRechargeable Lithium Battery
Response Time30 seconds at 95% variation
The Portable Oxygen Gas Detector is a compact, battery-operated device designed to measure oxygen (O) levels in ambient air. It is ideal for ensuring personnel safety in confined spaces, hazardous environments, laboratories, and process industries where oxygen levels may drop or exceed safe limits.
Portable Headspace Oxygen Gas Analyzer with Niddle Model ATS 101M. Sensor- Electro chemical Range-0-25%/30% Resolution-0.1% Sampling - Auto Suction Pump. Power- Battery Operated.
Zero CalibrationAutomatic at instrument start up with fresh air sample
Analog output4-20mA
The ATS-502SO2 Continuous Gas Analyzer is designed for the real-time, continuous monitoring of Sulphur Dioxide (SO) in industrial flue gas, stack emissions, and process control environments. It helps industries comply with emission regulations and maintain air quality standards, using reliable non-dispersive UV (UV-DOAS) or NDIR technology.
Technical Specifications:
ParameterDetails
Measured Gas
Sulphur Dioxide (SO)
Detection Principle
UV DOAS / NDIR (based on requirement)
Measurement Range
0200 / 0500 / 01000 / 05000 ppm (configurable)
Resolution
0.1 ppm or better
Accuracy
1% of reading or 2 ppm
Response Time (T90)
30 seconds
Display
LCD / OLED with real-time ppm values
Output Signal
420 mA / RS485 Modbus / Relay
Sample System
Heated sample line, probe with filter, gas cooler
Enclosure Protection
IP65 (outdoor version), Flameproof optional
Power Supply
230VAC / 24VDC
Operating Temp
0C to +50C
Calibration
Manual / Auto with calibration gas
Data Logging
Internal memory / USB / SCADA compatible
Key Features:
Continuous SO gas monitoring in real-time
Stable & accurate performance using UV/NDIR technology
SCADA/PLC connectivity via Modbus or analog output
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyPower Supply 230V AC
The Applied Online CO2 Gas Purity Analyzer Model ATS 208A with digital read out and alarms is a direct reading. Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED/Electrochemical as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature.
OPERATIONS- On start up, the instrument automatically goes through complete self integrity check, calibration check on demand. The press of sampling switch initiates the sampling through inbuilt suction pump and digitally displays the results.
DISCRIPTIONS- Its simple automatic operation, continuous measurement & digital display of purity concentration makes it a valuable aid for on site instant analysis & follow up action. Its data logging & computer interface features can be used for further detailed analysis in the laboratory. FEATURES- Complete Automatic Operation Self Diagnostic Check Proven Sensor Technology Inbuilt Suction Pump. RS 232/RS 485 and USB Computer Interface Single 320 X 240 Graphics LCD Display Intrinsically Safe. Continuous, Stable Alphanumeric Display
SPECIFICATIONS- Range : 0 - 100% V/V.0 to 50, 100, 1000PPM Minimum Resolution : 0.01 % Readout : 128 X 64 Graphics LCD Display Sampling Method : In Built Suction Pump Detection Principle : Thermal Conductivity / Infrared/Electrochemcial Accuracy : +/- 0.1% of Full Scale. Response Time : Less than 10 Seconds. Warm Up Time : 1 Minute. Dimensions : 430(W) X 150(H) X 250(D)mm. Accessories : Flow Meter, Warranty : One Year. A nalog Output : 4-20mA Digital Output : RS 232, RS 485, Relay output
Power SupplyInternal Ni-cad battery pack with external charger 220V 50Hz Ac (Optional 110V 50Hz)
Portable Flue Gas Analyzer
rn
Model ATS 206
rn
Small, Handheld, and an ideal test instrument for determining boiler and furnace combustion efficiency in pharmaceutical, oil and gas, power plant, and chemical industries.
SamplingAuto Suction Sampling through Inbuilt Pump
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyInternal Battery Pack with External Charger 230V / 50 Hz
Response Time30 seconds at 95% variation
Weight1.5kg
ATS Portable Flue Gas Analyzer Model ATS 206A is used to measure the concentration of Flue Gases produced by the combustion process in the Applications like Stack, Furnaces , Boilers & other industrial Applications.
Portable Flue Gas Analyzer ATS 206A measure O2, CO, CO2, SOx, NOx , HC etc. It is a customize instrument so that we can add other parameters as per Applications.
Gas Probes & Sampling System -Flue gas sampling probes with different lengths, shapes and max, operating temperatures Up to 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loaded applications.
OPERATION-On start up, the instrument automatically goes through complete integrity check, calibration cycle before displaying its readings for sampling. With the press of sampling switch, the analyzer automatically extracts the sample, analyses and display the concentrations of various gases in cyclic order. To stop or for further sampling at different locations or clearing with fresh air before switch off, one has to press the sample switch again.
Applications- In Quality Control Labs Process Analysis Stack Gas Analysis Fuel Efficiency Analysis Furnaces Diesel/Petrol Exhaust Emission Engine Exhaust Emission Internal Combustion Engines Burner Performance Monitoring Boiler Corrosion Ambient & Emission Monitoring Atmosphere Monitoring Burner Flame Control Underground Mines Excess Air Measurement
Specifications -
Accuracy : +/-2%.
Display : High quality 128 x 64 Graphics LCD.
Sampling : Auto Suction Sampling through Inbuilt Pump
Zero Calibration: Automatic at instrument start up with fresh air sample.
Power Supply : Internal Battery Pack with external Charger
SamplingAuto Suction Sampling through Inbuilt Pump
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyInternal Battery Pack with External Charger 230V / 50 Hz
Response Time30 seconds at 95% variation
ATS Portable Flue Gas Analyzer Model ATS 206A is used to masure the concentration of Flue Gases produced by the conbution process in the Applications like Stack, Furneces , Biolers & other industrial Applications.
Portable Flue Gas Analyzer ATS 206A measure O2, CO, CO2, SOx, NOx , HC etc. It is a costomise instrument so that we can add other parameters as per Applications.
Gas Probes & Sampling System - Flue gas sampling probes with different lengths, shapes and max, operating temperatures Up to 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications.
OPERATION- On start up, the instrument automatically goes through complete integrity check, calibration cycle before displaying its readings for sampling. With the press of sampling switch, the analyzer automatically extracts the sample, analyses and display the concentrations of various gases in cyclic order. To stop or for further sampling at different locations or clearing with fresh air before switch off, one has to press the sample switch again.
Applications- In Quality Control Labs Process Analysis Stack Gas Analysis Fuel Efficiency Analysis Furnaces Diesel/Petrol Exhaust Emission Engine Exhaust Emission Internal Combustion Engines Burner Performance Monitoring Boiler Corrosion Ambient & Emission Monitoring Atmosphere Monitoring Burner Flame Control Underground Mines Excess Air Measurement
Specifications -
Accuracy : +/-2%.
Display : High quality 128 x 64 Graphics LCD.
Sampling : Auto Suction Sampling through Inbuilt Pump
Zero Calibration: Automatic at instrument start up with fresh air sample.
Power Supply : Internal Battery Pack with external Charger
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Mercury-free
Availability0-5kg
Country of OriginIndia
Detected gasCO, DERIVED CO2, NOx, O2, SO2
Voltge3-6VDC
gas analyzers/flue gas analyzer /5 gas analyzer/ 6 gas analyzer/ exhaust gas analyzer
application :-
theflue gas analysissystem is suitable forflue gas, stack gas, exhaust gasemission sites of relatively clean combustion sites. it can be used forcontinuous monitoring of up to 5 components:nox, so2, co, co2, and o2. ideal for flue gas monitoring in waste incinerators, boilers, and furnaces.
Additional Information:
Payment Terms :
L/C, D/A, D/P, T/T, Western Union,
The Argon Purity Analyzer typically measures argon gas purity in the range of 0 to 100%, with impurity detection thresholds down to 1 ppm depending on the sensor type. It uses technologies such as thermal conductivity detectors (TCD), electrochemical sensors, or zirconia-based oxygen sensors for precise measurement. The device operates at an input gas pressure range of 1 to 10 bar and a flow rate between 0.2 and 2 L/min. Accuracy is usually within 1% of full scale, with repeatability better than 0.5%. Response time (T90) is less than 10 seconds. Operating voltage is 220V AC or 24V DC, and the ambient operating temperature range is 0C to 45C. The unit includes a digital LCD/LED display, RS232 or USB output for data logging, and calibration options for standard reference gases. Housing is typically made of aluminum or stainless steel, and the analyzer can be configured for portable, panel-mounted, or rack-mounted installations. Maintenance is minimal, and the device is factory calibrated with options for annual recalibration.
Additional Information:
Payment Terms :
L/C, D/A, D/P, T/T, Western Union,
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight
Number Of FlowerPortable Gas Analyzer
Country of OriginIndia
Detected gasH2 & CO2
Resolution0.1% of gas measured
Accuracy±0.2% of F.S
Response Time10-15 seconds to 90% step change
MaterialMS
WarrantyOne Year
Ambient Temperature0 to 55 ºC
Linearity±1.0% of F.S. on H 2in Air range ±2% of F.S. in H 2in CO2or Air in CO2ranges
PowerLithium Rechargeable Battery
Turbine Gas AnalyzerFor the Application of Hydrogen Purity.The Hydrogen Purity and Purge Gas analyzer have been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases.
Specifications:
Principle: Thermal Conductivity and NDIR (Non dispersive Infrared )
Range: %V/V
Resolution: 0.1 Unit or 1 Unit (Application based)
Sampling Method: Auto Suction or Direct Plug In
Display: 128 X 64 Graphics LCD
Alarm; Two Levels Low High, Visual and Audible
Power Source: Built in Lithium Rechargeable battery
Power Supplylithium Rechargeable battery with provision for charging with 230 V AC, 50 Hz power source
Display128 x 64 Graphics LCD
Resolution0.1%
Accuracy+/-1% Full scale
Linearity+/- 2 % Full scale
Response TimeLess than 10 seconds
The ATS-203 Turbine Gas Analyzer is a high-performance analyzer designed for the monitoring and analysis of gas composition in turbine systems, particularly in hydrogen-cooled turbo generators. It ensures the purity, efficiency, and safety of turbine operations by providing accurate real-time measurements of gas mixtures.
A Real-Time O Quality Analyzer** is designed tocontinuously monitor the concentration or purity of oxygen gasin various environments or gas mixtures. These analyzers are used in industries whereoxygen purity is critical, such as gas manufacturing, healthcare, food packaging (MAP), steel plants, and combustion control.
rn
The analyzer uses one of the following sensor types based on the required application:
rnrn
rn
rn
Zirconia Sensor Suitable for high-temperature applications and combustion systems
rn
rn
rn
Paramagnetic Sensor Ideal for accurate and stable measurement of O in gas mixtures
rn
rn
rn
Electrochemical Sensor Commonly used in portable and mid-range analyzers
rn
rn
rnApplications:rnrn
rn
rn
Oxygen purity check ingas manufacturing(industrial & medical O)
rn
rn
rn
Modified Atmosphere Packaging (MAP)in the food industry
rn
rn
rn
Combustion efficiencyoptimization in boilers/furnaces
rn
rn
rn
Inerting and blanketingin chemical/pharma sectors
rn
rn
rn
Continuous monitoring insemiconductor and electronics manufacturing
rn
rn
rn
Medical gas systems inhospitals and clinics
rn
rn
rnFeatures:rnrn
rn
rn
Real-time, continuous oxygen purity display
rn
rn
rn
User-friendly interface with live graph & history view
ThePortable Oxygen Purity Analyserhave been design especially for cylindrical and power station to check the Hydrogen Purity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features Simple Low Cost maintenance Microcontroller based embedded intelligent
Specification:
Principle Thermal Conductivity and NDIR (Non dispersive Infrared )
Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In
Display 128 X 64 Graphics LCD
Alarm Two Levels Low High Visual and Audible
Power Source Built in Lithium Rechargeable battery
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyRechargeable Ni-cad Battery Pack with Charger
ThePortable Nitrogen Purity Analyzeris a compact, battery-operated instrument used to measure thepurity of Nitrogen gas (N)in industrial, laboratory, and on-site applications. It offers high accuracy, quick response, and ease of use making it ideal forcylinder verification, nitrogen generation plants, food packaging (MAP), and gas purity validation.
Technical Specifications:
ParameterDetails
Gas Measured
Nitrogen (N) Purity
Measurement Principle
Thermal Conductivity (TCD) / Electrochemical (O balance)
Measuring Range
80% to 99.999% N (or 010, 000 ppm O)
Display
Digital LCD / OLED with backlight
Resolution
0.01% or 1 ppm (based on configuration)
Accuracy
0.1% of full scale
Response Time (T90)
10 seconds
Sampling Method
Built-in sampling pump or diffusion (configurable)
Battery
Rechargeable Li-ion (810 hrs backup)
Data Logging
Optional (USB or SD card)
Alarm Output
Audible + Visual
Operating Temperature
0C to +50C
Calibration
Via certified gas (O or N mix)
Accessories
Tubing, charger, carrying case, calibration cap
Key Features:
Real-time Nitrogen purity checkon-site
Compact, rugged, portable design
Bright display withauto-backlight for low-light use
Audio-visual alarmon low purity detection
Easy calibration andlow maintenance
Optionaldata loggingfor traceability and audits
Applications:
Nitrogen generator (PSA/VPSA) commissioning
Pharmaceutical and biotech labs
MAP (Modified Atmosphere Packaging)in food industry
Number Of FlowerPortable Analyzer, Purity Analyzer
Availability0-5kg
Total CarbohydrateOne Year
Country of OriginIndia
Detected gasCO2
MaterialMild Steel
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry
Range0-100% V/V
Accuracy+/-2%
DisplayHigh quality 128 x 64 Graphics LCD
SamplingDirect Plugin
Power SupplyRechargeable Ni-cad Battery Pack with Charger
SensorNDIR
ThePortable Carbon Dioxide Purity Analyserhave been design especially for cylindrical and power station to check theCarbon dioxidePurity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features Simple Low Cost maintenance Microcontroller based embedded intelligent.
Specification:
Principle Thermal Conductivity and NDIR (Non dispersive Infrared )
Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In
Display 128 X 64 Graphics LCD
Alarm Two Levels Low High Visual and Audible
Power Source Built in Lithium Rechargeable battery
Micro controller based portable NO NO2 and Nox analyzer having measuring range nfrom 0-1000 ant uptop 5000 PPM with electrochemical or NDIR technology having facility of data logging along with the temperature sensor probe Model ATS206A Rechargable Battery Operated Instruments flue Gas Analyzer can use upto 1200 degree cantigrate Flue Gas Analyzer Model ATS206A also used for the measurement of stack efficiency, diffferencial pressure and temperature
ApplicationUED CHECK THE CONCENTRATION OF DIFFRENT PARAMETRS
TheATS 206A Portable Flue Gas Analyzeris used for measuring the total volumetric discharge of particulate matter and gaseous pollutants from the stacks. The kit is used for sampling the gaseous stream effluents that is essential to be measured and monitored for all industrial establishments. These effluents has to be controlled in compliance with Air Prevention and Control of Pollution Act of 1981.
The kit is used for taking isokinetic samples of effluents that are emitted from various industrial processes including chemical and combustion process.
The kit is designed to work and operate in horizontal as well as vertical position with its sampling probe and can be used in round or rectangular stacks and ducts with flow velocity ranging from 1 to 40 m/sec and temperatures up to 600C or higher.
Usage/ApplicationTO CHECH CONCERTRATION OF BIOGAS (O2, CO, CO2, CH4, H2S)
Portable Biogas Analyzer with printer Backed by rich industry experience, we are affianced in providing a qualitative assortment ofBiogas Analyzer. Being a quality-oriented firm, we promise our clients that this Analyzer is the best in quality. Our deft professionals only use fine quality components, while manufacturing the entire range. Moreover, our offered Analyzercan be availed in a wide array of models and other related specifications as per the requirements of our esteemed clients. It is especially for Bio gas Application for the analysis of Biogas CH4, CO2, and He Biogas Analyzer& Oxygen.
Other Details:
Simple Low Cost maintenance
Microcontroller based embedded intelligent instruments
CH4 gas Range : 0-100%V/V
CO2 Range 0-100% V/V
H2S Range 0-1000 PPM (Optional 10000 PPM)
Oxygen 0-25% V/V
User friendly Interface
Direct Plug In Or Auto Suction Sampling
128 x 64 Graphics LCD Display
USB/RS 232 Computer Interface
Long Life Rechargeable Li-IONE Battery
Application:
Hydrogen Cooled Alternators & Turbine
Hydrogen Analysis
MAP (Food Gas Packaging)
Gasification & Syngas
Metal Heat Treatment Plant
Laboratories & Institutions
Treatment Process & Chemical Industries
Petrochemical & Pharmaceutical Industries
Specification:
Principle
NDIR/EC/Thermal Conductivity and NDIR (Non dispersive Infrared )
ApplicationCombustion Gas Anlysis, Flue Gas Analysis
CertificationCE Certified, ISO 9001:2008
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Low Battery Consumption, Mercury-free
Gasification is a process where a fuel or feedstock is cooked in low oxygen conditions. The equipment that carries out this whole process is usually called a gasifier.Different zones inside the gasifier support drying, pyrolysis, combustion, and reduction reactions. The whole process produces gas that contains primarily carbon monoxide and hydrogen. These gases can be carried away before they combust, and then used elsewhere for energy. The gas is often called synthesis gas or syngas for short. It has also been referred to in the past as producer gas or town gas.Producer Gas Analyzerhas been designed considering the flexibility required in the environments that characterize syn gas and bio-mass applications.
The analyzer uses high-stability infrared sensors for the simultaneous measurement of CO, CO2 and CH4 . In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2 and CH4 . This ensures that H2 will always read 2correctly regardless of the background gas composition. Paramagnetic sensor can be used for O2 analysis as an option.
All sensors are temperature-compensated for maximum analytical stability.
ApplicationCombustion Gas Anlysis, Flue Gas Analysis, BIOGAS ANALYSIS
CertificationCE Certified, ISO 9001:2008
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight, Low Battery Consumption, Mercury-free
Gasification is a process where a fuel or feedstock is cooked in low oxygen conditions. The equipment that carries out this whole process is usually called a gasifier.Different zones inside the gasifier support drying, pyrolysis, combustion, and reduction reactions. The whole process produces gas that contains primarily carbon monoxide and hydrogen. These gases can be carried away before they combust, and then used elsewhere for energy. The gas is often called synthesis gas or syngas for short. It has also been referred to in the past as producer gas or town gas.Producer Gas Analyzerhas been designed considering the flexibility required in the environments that characterize syn gas and bio-mass applications.
The analyzer uses high-stability infrared sensors for the simultaneous measurement of CO, CO2 and CH4 . In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2 and CH4 . This ensures that H2 will always read 2correctly regardless of the background gas composition. Paramagnetic sensor can be used for O2 analysis as an option.
All sensors are temperature-compensated for maximum analytical stability.
Online ammonia gas analyzers Model ATS 208A ia a analyzer for monitoring ammonia levels in various industrial and environmental settings. These devices provide real-time, continuous measurements, enabling prompt response to potential hazards and ensuring compliance with regulatory standards.
Applications of Online Ammonia Gas Analyzers:1-Industrial Process- 2-Research & Lab3-Safety Tools Specifications -: Range : .0 to 50, 100, 100PPM Minimum Resolution : 0.01 % Readout : 128 X 64 Graphics LCD Display Sampling Method : In Built Suction Pump Detection Principle : Thermal Conductivity / Infrared/Electrochemcial Accuracy : +/- 0.1% of Full Scale. Response Time : Less than 10 Seconds. Warm Up Time : 1 Minute. Dimensions : 430(W) X 150(H) X 250(D)mm. Accessories : Flow Meter, Warranty : One Year. Analog Output : 4-20mA Digital Output : RS 232, RS 485, Relay output
Applied Techno Systems Online VOC (Volatile Organic Compound) gas analyzer is designed for continuous, real-time Analysis of VOCs present in a gaseous sample medium. Like laboratory, Paint booth Exhaust & in other industrial stream, online analyzers provide immediate data, enabling timely responses to changing conditions and potential hazards. The technology used to measure the VOC is Photoionization Detector ( PID).
Application -; 1-Industrial Emission Monitoring. 2-Air Quality Monitoring. ( Ambient & Indoor) 3-Process Control in manufacturing. 4-Research & Developements
Specifications -: Sensor - PID Range- 0-500 PPM, 1000 PPM, 2000 PPM Display - Graphics Display Sampling - Direct Plugin & Auto Suction Pump Responce Time -< 5 Sec Accuracy - +/- 0.1% at Full Scale Analog Out put - 4-20mA Digital Output - RS485 or RS232
Zero CalibrationAutomatic at instrument start up with fresh air sample
Response Time30 seconds at 95% variation
The Applied Online CO2 Gas Purity Analyzer Model ATS 208A with digital read out and alarms is a direct reading. Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED/Electrochemical as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature. OPERATIONS-On start up, the instrument automatically goes through complete self integrity check, calibration check on demand. The press of sampling switch initiates the sampling through inbuilt suction pump and digitally displays the results. DISCRIPTIONS-Its simple automatic operation, continuous measurement & digital display of purity concentration makes it a valuable aid for on site instant analysis & follow up action. Its data logging & computer interface features can be used for further detailed analysis in the laboratory. FEATURES-Complete Automatic Operation Self Diagnostic Check Proven Sensor Technology Inbuilt Suction Pump. RS 232/RS 485 and USB Computer Interface Single 320 X 240 Graphics LCD Display Intrinsically Safe. Continuous, Stable Alphanumeric Display SPECIFICATIONS- Range : 0 - 100% V/V.0 to 50, 100, 1000PPM Minimum Resolution : 0.01 % Readout : 128 X 64 Graphics LCD Display Sampling Method : In Built Suction Pump Detection Principle : Thermal Conductivity / Infrared/Electrochemcial Accuracy : +/- 0.1% of Full Scale. Response Time : Less than 10 Seconds. Warm Up Time : 1 Minute. Dimensions : 430(W) X 150(H) X 250(D)mm. Accessories : Flow Meter, Warranty : One Year. A nalog Output : 4-20mA Digital Output : RS 232, RS 485, Relay output
• Zero CalibrationAutomatic at instrument start up with fresh air sample
• Power Supply230V AC
The ATS-205A is the ideal solution for measuring trace oxygen in a wide range of applications in a general purpose environment. In a compact size, and at low cost
The MODEL ATS-205A Portable Trace Oxygen Analyzer is the undisputed leader when measuring ppm levels of oxygen in the natural gas industry. Patented innovations and key features are packed into a compact, rugged design. The patented Cell Block and sensor technology combination produce an incredibly fast and reliable O2 measurement. The datalogging feature serves as a critical tool when searching for difficult intermittent leaks in the field.
Single measurement ranges are available from 0-10 PPM, 0-100 PPM, 0-2000 PPM & 0-10000 PPM with values displayed on a front panel 128X64 Graphics.
APPLICATIONS Oil & Gas refineries Chemical & Pharmaceuticals Airospace Industries Laboratory research industries Oxygen and nitrogen generators Storage holds on marine vessels post maintenance Oxygen in tankers during delivery Metal treatment processes Leak checking processes Double glazing manufacture Welding (under N2 or Ar purge) Air Separation Industries
The Applied Online Hydrogen Gas Analyzer Model ATS 208A with digital read out and alarms is a direct reading. Gas Purity Analyzer, designed to serve the demanding field requirements of various gases Producing and using Industry. It is designed to replace the cumbersome and time consuming Or set apparatus and provide quick and accurate reading of gas Purity. It offers the user a distinct advantage in terms of economy, dependability maintenance and ease of operation. The instrument incorporate TCD / INFRARED/Electrochemical as a transducer. It has adjustable visual and audible alarms with Automatic Zero Calibration Feature.
SCRIPTION FEATURES 1-Complete Automatic Operation 2-Self Diagnostic Check 3-Proven Sensor Technology. 4-Inbuilt Suction Pump. 5-Control Unit (FP) Control Unit (WP) 6-RS 232/RS 485 and USB Computer 7-Interface Single 320 X 240 Graphics LCD Display 8-Intrinsically Safe. 9-Continuous, Stable Alphanumeric Display
Producer gas analyzer Model ATS 204A is portable type instrument used to determine the composition of producer gas, which is generated through the gasification of various carbonaceous materials like biomass or coal The primary function is to measure the concentrations of key gases within the producer gas, including:
Carbon monoxide (CO)
Carbon dioxide (CO2)
Hydrogen (H2)
Methane (CH4)
Oxygen (O2)
Nitrogen (N2)
Applications:
Biomass Gasification:
Monitoring the gas quality from biomass gasifiers for heat and power generation.
Coal Gasification:
Analyzing the producer gas from coal gasification plants.
Industrial Processes:
Used in various industrial applications where producer gas is utilized as a fuel or feedstock.
Specification-:
NDIR Sensor for CO, CO2 & CH4 Range 0-100% V/V
TCD Sensor for Hydrogen (H2) Range 0-100% V/V
Electro Chemical Sensor for Oxygen Range 0-100% V/V
A portable trace oxygen analyzer is a device used to measure the concentration of oxygen in a gas sample at very low levels, typically in parts per million (ppm). These analyzers are designed for portable use, which makes them useful in a variety of applications, such as in industrial processes, environmental monitoring, safety checks, and research.
rn
Key Features and Applications:
rnrn
rn
Sensitivity and Accuracy:
rn
rn
Portable trace oxygen analyzers are highly sensitive, capable of detecting oxygen concentrations at very low levels (typically in the range of 0-100 ppm).
rn
They provide accurate and reliable readings, ensuring compliance with environmental standards, quality control, and safety.
rn
rn
rn
rn
Technology:
rn
rn
These analyzers often use technologies such aselectrochemical sensors, paramagnetic sensors, orzirconium oxide sensorsto detect oxygen. The choice of sensor technology can affect the speed, accuracy, and maintenance requirements of the device.
rn
rn
rn
rn
Portable Design:
rn
rn
Compact and lightweight, portable trace oxygen analyzers are designed to be carried and used in various locations, making them suitable for field testing and mobile operations.
rn
rn
rn
rn
Applications:
rn
rn
Environmental Monitoring: Monitoring oxygen levels in air, especially in confined spaces or remote locations.
rn
Industrial Processes: For controlling the oxygen content in processes like welding, gas production, and chemical manufacturing.
rn
Safety: In industries like mining, oil, and gas, ensuring that oxygen levels are safe to prevent asphyxiation or combustion hazards.
rn
Research: Used in laboratories for experiments that require precise oxygen measurements.
rn
rn
rn
rn
Calibration and Maintenance:
rn
rn
Regular calibration is essential to maintain accuracy. Many models offer self-calibration features or come with user-friendly calibration procedures.
rn
rn
rn
rn
Display and Interface:
rn
rn
Most portable trace oxygen analyzers feature digital displays and allow for easy reading of oxygen concentrations. Some models also offer data logging capabilities and interfaces for connecting to external devices for data analysis.
Zero CalibrationAutomatic at instrument start up with fresh air sample
Response Time30 seconds at 95% variation
The ATS-205A is the ideal solution for measuring trace oxygen in a wide range of applications in a general purpose environment. In a compact size, and at low cost
The MODEL ATS-205A Portable Trace Oxygen Analyzer is the undisputed leader when measuring ppm levels of oxygen in the natural gas industry. Patented innovations and key features are packed into a compact, rugged design. The patented Cell Block and sensor technology combination produce an incredibly fast and reliable O2 measurement. The datalogging feature serves as a critical tool when searching for difficult intermittent leaks in the field.
Single measurement ranges are available from 0-10 PPM, 0-100 PPM, 0-2000 PPM & 0-10000 PPM with values displayed on a front panel 128X64 Graphics.
APPLICATIONS Oil & Gas refineries Chemical & Pharmaceuticals Airospace Industries Laboratory research industries Oxygen and nitrogen generators Storage holds on marine vessels post maintenance Oxygen in tankers during delivery Metal treatment processes Leak checking processes Double glazing manufacture Welding (under N2 or Ar purge) Air Separation Industries
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight
Number Of FlowerPortable Analyzer, Analyzer
Country of OriginIndia
Accuracy+/-2% & 0.5%
ColorGrey
ConditionNew
Automation GradeAutomatic
Weight0-5kg
WarrantyOne Year
Detected gasDERIVED CO2, O2, CO2, H2S, CH4 & O2
DisplayHigh quality 128 x 64 Graphics LCD
MaterialMS
SamplingAuto Suction Sampling through Inbuilt Pump
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyLithium Rechargeable Battery
Response Time30 seconds at 95% variation
AlarmTwo Level (Selectable Range)
A continuous surveillance of the produced biogas is necessary to efficiently control the production process of a biogas plant. Methane, Residual oxygen, carbon dioxide & hydrogen sulphide in the gas stream can be measured simultaneously or singularly.
ATS- 201A (Bench Top) Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on site instant analysis and follow up action. Its data logging.
Applications - Process surveillance of the fermentation of biogas. Gas Analysis In Laboratory Optimization of the calorific value. Protection of the gas turbines from high hydrogen sulphide concentrations. Differing customer specific measuring requirements upon request.
Operations -Electrochemical sensor for O2. Data logging and software for data downolad. Date & time stamp. Custom designed sample Conditioning system. Analog / Digital Output (optional). Extra long life oxygen sensor not Poisoned with Co2.
Method of Detection-NDIR infrared sensor for CO2, CH4 Electrochemical sensor for O2, H2S, CO, NH3 TCD or Solid State for H2 (Optional)
SpecialitiesEasy To Use, Eco-Friendly, High Pressure, Light Weight
Extinguisher Capacity1-5kg
Warranty1 Year, One Year
Accuracy+/-2%
DisplayHigh quality 128 x 64 Graphics LCD
SamplingAuto Suction Sampling through Inbuilt Pump
Zero CalibrationAutomatic at instrument start up with fresh air sample
Power SupplyLithium Rechargeable Battery
A continuous surveillance of the produced biogas is necessary to efficiently control the production process of a biogas plant. Methane, Residual oxygen, carbon dioxide & hydrogen sulphide in the gas stream can be measured simultaneously or singularly.
ATS- 201A (Bench Top) Its simple automatic operation, continuous measurement and digital display of gas and makes it a valuable aid for on site instant analysis and follow up action. Its data logging. Applications - Process surveillance of the fermentation of biogas. Gas Analysis In Laboratory Optimization of the calorific value. Protection of the gas turbines from high hydrogen sulphide concentrations. Differing customer specific measuring requirements upon request. Operations -Electrochemical sensor for O2. Data logging and software for data downolad. Date & time stamp. Custom designed sample Conditioning system. Analog / Digital Output (optional). Extra long life oxygen sensor not Poisoned with Co2. Method of Detection-NDIR infrared sensor for CO2, CH4 . Ranges Available:-1-CH4 0-25.0%, 0-50.0%, 0-100.0% 2-CO2 0-10.0%, 0-50.0%, 0-100.0%
SamplingAuto Suction Sampling through Inbuilt Pump
Analogue Output4-20mA
Online Ozone Monitor Model ATS-208A
Model ATS - 208A Gas Analyzer continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. Feature includes a duel wavelength sensor, Remote Sampling, Graphics LCD Display, adjustable level relay output for alarm and 4-20mA output for control purpose and minimal maintenance
The Online NOx Analyzer is designed for the continuous monitoring of Nitrogen Oxides (NO and NO) in industrial flue gas and emissions. It uses NDIR or Chemiluminescence technology to ensure accurate and real-time measurement. Suitable for power plants, boilers, cement, and process industries, the analyzer helps comply with CPCB emission norms. It supports 420 mA / RS485 outputs, making it easy to integrate with SCADA or CEMS systems. The system includes a gas sampling unit, and is available in wall-mount or cabinet type.
TheSulphur Dioxide Gas Analyzeris designed foraccurate and continuous measurement of SO2 gas concentrationin ambient air, industrial stacks, and process gas environments. Ideal for emission monitoring and environmental compliance, this analyzer ensures reliable detection in industries likepower generation, cement, chemicals, and refineries.
Being a quality driven organization, we are actively committed towards offering quality assuredNOX Gas Analyserthat is continuously monitors the concentration of gases ranging from 100%V/V down to PPM level. The offered analyzer is precisely manufactured using best grade raw material and advanced technology. We assure our clients that our range is quality examined against predefined quality parameters, in order to meet international standards. Apart from this, our esteemed clients can avail the entire range, as per their needs, at reasonable price. Features:
Long operational life
Smooth functioning
Rugged design
Other Details:
Microcontroller based embedded intelligent instruments
Continuous Monitoring of CO2 , CH4, CO, O2, SO2, NOX (NO+NO2), H2, H2S, N2
Duel wavelength Infra red sensor for Long terms accuracy and stability
Long Life Electrochemical sensor
Six Gas Analysis in Single Analyser
Multi Parameter Single 320 X 240 Graphics LCD Display
Self diagnostic Self integrity check
RS 232/RS 485 and USB Computer Interface
Excellent low level capability for NOX and SO2 Measurement
For most of the application sample gas is cooled and dried inside the sampling conditioning systems to avoid the Heated Sample Line.
Analog 4-20mA output for each gas
Software solutions for Gas Analysis
Web Based Real time data transfer with GSM/GPRS Technology.
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight
Number Of FlowerStack Gas Analyzers, Analyzer
Availability0-5kg
Country of OriginIndia
MaterialMS
WarrantyOne Year
Accuracy+/-2%
• DisplayHigh quality 128 x 64 Graphics LCD
• SamplingAuto Suction Sampling through Inbuilt Pump
• Zero CalibrationAutomatic at instrument start up with fresh air sample
• Power SupplyInternal Battery Pack with External Charger 230V / 50 Hz
ATS Portable Flue Gas Analyzer Model ATS 206A is used to masure the concentration of Flue Gases produced by the conbution process in the Applications like Stack, Furneces , Biolers & other industrial Applications.
Portable Flue Gas Analyzer ATS 206A measure O2, CO, CO2, SOx, NOx , etc. It is a costomise instrument so that we can add other parameters as per Applications.
Gas Probes & Sampling System -Flue gas sampling probes with different lengths, shapes and max, operating temperatures Up to 1600C are available to match various requirements of different applications. A sintered pre-filter is suggested for severe and having dust loded applications.
OPERATION-On start up, the instrument automatically goes through complete integrity check, calibration cycle before displaying its readings for sampling. With the press of sampling switch, the analyzer automatically extracts the sample, analyses and display the concentrations of various gases in cyclic order. To stop or for further sampling at different locations or clearing with fresh air before switch off, one has to press the sample switch again.
Applications- In Quality Control Labs Process Analysis Stack Gas Analysis Fuel Efficiency Analysis Furnaces Diesel/Petrol Exhaust Emission Engine Exhaust Emission Internal Combustion Engines Burner Performance Monitoring Boiler Corrosion Ambient & Emission Monitoring Atmosphere Monitoring Burner Flame Control Underground Mines Excess Air Measurement
Specifications -
Accuracy : +/-2%.
Display : High quality 128 x 64 Graphics LCD.
Sampling : Auto Suction Sampling through Inbuilt Pump
Zero Calibration: Automatic at instrument start up with fresh air sample.
Power Supply : Internal Battery Pack with external Charger
FeatureAdjustable, Easy Available, Fine Finished, High Quality, High Strength
Packaging TypeBox
Number Of FlowerBroken Bag Detector
Country of OriginIndia
Broken Bag Detectoris a device that is mounted in the discharge stack of a dust collector and continuously monitors the amount of particulate discharge. The particulate monitor uses a technology known as Triboelectric or Triboelectricity. When two different materials come in contact, it is likely that one will leave with more electrons than it started with and the other will leave with less, this is called Triboelectric Effect. The interaction between the probe and particles produces a charge transfer within the probe. The charge is then converted to an output signal.The advanced electronics of the Monitor detect this signal and present it to the operator via a modulating Graphical display.
Accuracy±3% of reading or ±0.02% of range (except for ranges ≤ 100 ppm: ±3% of reading or ±0.05% of range)
Range0 to 2000 ppm
Dimensions(196 x 100 x 40) mm approximately.
A trace oxygen analyzer is an instrument used to measure very low concentrations of oxygen in gases. These analyzers are typically used in industries or research where precise control of oxygen levels is crucial. They can detect oxygen levels in parts per million (ppm) or even parts per billion (ppb), depending on the sensitivity of the analyzer.
Additional Information:
Payment Terms :
Packaging Details :The product will be securely packaged in a Thermocal box, designed to provide thermal insulation and protection during transit. Each unit will be sealed in a protective plastic cover to prevent dust, moisture, and other contaminants from damaging the product during transport and storage. Including Calibration Certificate, Warranty Certificate & Operation Manual
Calibration methodManual or Automatic / Remote Calibration 2-Point calibration span and zero
Display Type320x264 Graphics High Quality LCD
Outputs/InputsIsolated current loops One per gas 4-20 mA
Operating (ambient) Temp.-40deg C to + 50deg C
The HCL Dual-Screen Gas Analyzer** is a high-precision device designed tocontinuously monitor the concentration of hydrogen chloride (HCl) gasin industrial environments. Featuring adual-screen interface, it providesreal-time readings, historical data access, and enhanced operational safety for industries dealing with corrosive or toxic gases.
Usage/ApplicationThe instrument incorporate TCD / INFRARED as a transducer.
Warranty1 Year
Accuracy+/- 2% of Full Scale
An N2 Purity Analyzer is an instrument used to measure the purity or concentration of nitrogen (N) gas in a mixture. Nitrogen is commonly used in industries like chemical manufacturing, food packaging, and pharmaceuticals, and its crucial to maintain specific purity levels in these applications.
Key Features of an N2 Purity Analyzer:
Accuracy: Provides precise measurement of nitrogen purity, often expressed as a percentage.
Measurement Range: It measures nitrogen concentration in a range from low percentages (e.g., 95%) up to high purity (e.g., 99.999%).
Methods of Detection:
Thermal Conductivity Detector (TCD): Most common method for detecting gases, based on the difference in thermal conductivity between nitrogen and other gases in the mixture.
Gas Chromatography (GC): Can be used for more detailed analysis, separating gases before detection.
Optical Methods: Some advanced analyzers use optical sensors or infrared spectroscopy.
Portability: Some models are portable for on-site monitoring, while others are stationary, typically found in industrial settings.
Real-time Monitoring: Allows for continuous measurement of nitrogen purity, providing real-time data for operators.
Applications:
Gas Production: Monitoring nitrogen purity in industrial gas production facilities.
Pharmaceuticals: Ensuring proper nitrogen purity in packaging to avoid oxidation or contamination.
Food & Beverage: Ensuring the purity of nitrogen used for food packaging to extend shelf life.
Laboratories: Measuring nitrogen purity for scientific experiments requiring specific nitrogen concentrations.
Additional Information:
Payment Terms :
Packaging Details :The product will be securely packaged in a Thermocal box, designed to provide thermal insulation and protection during transit. Each unit will be sealed in a protective plastic cover to prevent dust, moisture, and other contaminants from damaging the product during transport and storage. Including Calibration Certificate, Warranty Certificate & Operation Manual
FeatureAccuracy, Durable, Eco Friendly, Portable, In Built Suction Pump
CertificationAn ISO 9001:2015 Company
ApplicationGas Detecting
ConditionNew
Brand NameApplied Techno Engineers Pvt. Ltd.
Number Of FlowerPortable Gas Detector
Display Type128 X 64 Graphics LCD
Power SourceBattery
MaterialABS Plastic
Detector TypeMonitor
Warranty1Year
Power3.7 Lithium rechargeable batteries with
Operating Voltage- 10 Deg. C to 55 Deg. C
Response Time<10 seconds at 95% variant
ThePortable MAP Analyzeris a compact, handheld instrument designed to measureOxygen (O)and indirectlyNitrogen (N)concentrations inModified Atmosphere Packaging (MAP). This is essential for ensuringproduct freshness, shelf life, andregulatory complianceinfood, beverage, pharmaceutical, andbiotechindustries.
Key Features:
Fast and accuratereadings in under 10 seconds
Rechargeable batterywith 812 hours of operation
Compact, portable designideal for field use
Needle-type sampling probefor direct pack testing
LCD display with O and N readings
Optionaldata loggingwith USB or Bluetooth download
Easy to clean and operate ideal for hygienic environments
Built-in filter to protect sensor from dust or particles
FeatureAccuracy, Battery Indicator, Digital Display
Number Of FlowerGas Analyzers
Availability0-5kg
Country of OriginIndia
Detected gasCO, O2, CO2, H2, CH4 & N2
MaterialMS
Method of DetectionNDIR infrared sensor for CO, CO2, CH4 Electrochemical sensor for O2 (Paramagnetic optional) Thermal conductivity cell for H2
Ranges AvailableO 2 0-25.0%, 0-50.0%, 0-100.0% H2 0-5.0%, 0-50.0%, 0-100.0% CO 0-10.0%, 0-50.0%, 0-100.0% CO 2 0-10.0%, 0-50.0%, 0-100.0%
Processor32 - bit
Display128 x 64 Graphics Color LCD Display
Resolution0.01% for all gases
SamplingThrough Inbuilt Auto Suction Pump
Accuracy & Repeatability± 2% of reading for all gases
WarrantyOne Year
Response TimeLess than 30 seconds to 95% step change
Producer Gas Analyzer
Basically, gasification is a process where a fuel or feedstock is cooked in low oxygen conditions. The equipment that carries out this whole process is usually called a gasifier.
Different zones inside the gasifier support drying, pyrolysis, combustion, and reduction reactions. The whole process produces gas that contains primarily carbon monoxide and hydrogen. These gases can be carried away before they combust, and then used elsewhere for energy. The gas is often called synthesis gas or syngas for short. It has also been referred to in the past as producer gas or town gas.
Applied Model ATS 204A Producer Gas Analyzer has been designed considering the flexibility required in the environments that characterize syn gas and bio-mass applications.
The analyzer uses high-stability infrared sensors for the simultaneous measurement of CO, CO2 and CH4 . In addition, the analyzer can also be supplied with a non-consumable, long-life thermal conductivity cell for H2 that compensates for the interference effects of CO, CO2 and CH4 . This ensures that H2 will always read 2correctly regardless of the background gas composition. Paramagnetic sensor can be used for O2 analysis as an option.
All sensors are temperature-compensated for maximum analytical stability.
Applied Techno Systems Advantages
Ensured after sales & service support
Spares and accessories availability guaranteed
Low cost of ownership, maintenance and installation
Combination of technologies and integration under one roof
ATS-202A Oxygen Gas Analyseris single of Multigas Portable Instrument for Bio Gas and process gas Analysis for various industries Institution. Its measure CO2, Oxygen (O2), CH4, H2S Many More Landfill gas and Bio gas is produced by the bio-degradation of waste. Landfill gas is produced from general waste buried in the ground; and bio-gas from plant and animal waste products contained in a sealed digester tank.
Both gases comprise mainly methane (CH4) and carbon dioxide (CO2). The methane component is either burnt as a fuel or flared off as waste.
Additional Information:
Payment Terms :
T/T, Western Union
Packaging Details :ATS-202A Oxygen Gas Analyser is single of Multigas Portable Instrument for Bio Gas and process gas Analysis for various industries Institution. Its measure CO2, Oxygen (O2), CH4, H2S Many More Landfill gas and Bio gas is produced by the bio-degradation of waste. Landfill gas is produced from general waste buried in the ground; and bio-gas from plant and animal waste products contained in a sealed digester tank.
Both gases comprise mainly methane (CH4) and carbon dioxide (CO2). The methane component is either burnt as a fuel or flared off as waste.
Number Of FlowerPortable Analyzer, Purity Analyzer
Availability0-5kg
Total CarbohydrateOne Year
Country of OriginIndia
Detected gasCO2
MaterialMS
FeatureAccuracy, Battery Indicator, Digital Display, Easy To Carry, Highly Competitive, Light Weight
Range0-100% V/V
Accuracy+/-2%
DisplayHigh quality 128 x 64 Graphics LCD
SamplingDirect Plugin
Power SupplyRechargeable Ni-cad Battery Pack with Charger
Response Time30 seconds at 95% variation
ThePortable Carbon Dioxide Purity Analyserhave been design especially for cylindrical and power station to check theCarbon dioxidePurity. The Analyzer is supplied in robust and reliable construction having Li-IONE rechargeable battery with 6 Hour of continuous operation. The integral Pump, Needle valve and Flow meter are used to control the sample through the analyzer during the monitoring of alternator gases. Features Simple Low Cost maintenance Microcontroller based embedded intelligent.
Specification:
Principle Thermal Conductivity and NDIR (Non dispersive Infrared )
Range %V/V Resolution 0.1 Unit or 1 Unit (Application based) Sampling Method Auto Suction or Direct Plug In
Display 128 X 64 Graphics LCD
Alarm Two Levels Low High Visual and Audible
Power Source Built in Lithium Rechargeable battery