Contact SupplierWe are an established Supplier of Multi Line Three Phase Panel Meters. The Meters we make available are designed for accurate and reliable measurement of electrical quantities (voltage, current, power, frequency, etc.) in industrial and commercial applications. We have the expertise to address the bulk requirements of the buyers within the allocated time.
More about Elite 440 Multiline three phase panel meter :
Applications :
Benifits :
Features :
Features
|
Models | |||||||
---|---|---|---|---|---|---|---|---|
441 | 442 | 443 | 444 | 445 | 446 | 447* | 448* | |
P-N Voltage | • | • | • | • | • | • | • | • |
Average P-N Voltage | • | • | • | • | • | • | • | • |
P-P Voltage | • | • | • | • | • | • | • | • |
Average P-P Voltage | • | • | • | • | • | • | • | • |
Line Current (L1, L2, L3 and Average) | • | • | • | • | • | • | • | • |
Active / Reactive Current |
• | • | • | • | • | • | • | • |
Frequency |
• | • | • | • | • | • | • | • |
Power Factor | • | • | • | • | • | • | • | |
Average Power Factor | • | • | • | • | • | • | • | |
Active Power | • | • | • | • | • | • | • | |
Total Active Power | • | • | • | • | • | • | • | |
Reactive Power | • | • | • | • | • | • | ||
Total Reactive Power | • | • | • | • | • | • | ||
Apparent Power | • | • | • | • | • | • | • | |
Total Apparent Power | • | • | • | • | • | • | • | |
Active Total Import/ Export Energy | • | • | • | • | ||||
Reactive Import (Q1+ Q2) / Export (Q3+Q4 Energy) | • | • | ||||||
Reactive (Q1, Q2, Q3, Q4) Energy | • | • | ||||||
Apparent Import / Export Energy | • | • | • | • | ||||
Active / Apparent Forwarded | • | • | • | |||||
Reactive Lag / Lead Forwarded | • | • | ||||||
Cumulative MD | • | • | • | • | • | |||
Phase Angle | • | • | • | • | • | • | ||
Power On/ Off Hours | • | • | • | • | • | • | ||
Load On/ Off Hours | • | • | • | • | • | • | • | |
Feeder Inerupptions Count (When Aux is also off) | • | • | • | • | • | • | ||
Min/ Max Values | • | • | ||||||
THD Voltage | • | • | ||||||
THD Current | • | • | ||||||
THD Power | • | • | ||||||
RPM with Freq and VUnb and IUnb | • | • | • | • | • | • | • | |
Modbus on RS 485 | • | • | • | • | • | • | • | • |
Parameters | Accuracy Class0.2 | Acuracy Class 0.5 |
---|---|---|
Voltage | 0.1 | 0.1 |
Current | 0.1 | 0.1 |
KW | 0.2 | 0.5 |
KVar | 0.2 | 0.5 |
KVA | 0.2 | 0.5 |
KWh | 0.2 | 0.5 |
Kvarh | 0.2 | 0.5 |
Power Factor | 0.2 | 0.5 |
Frequency | 0.1 | 0.1 |
|
|
---|---|
Approvals | IS13779, IS 14697, IEC62052-11 and IEC62053-22, IEC60688, IEC61010 |
|
|
|
|
|
|
|
|