Our Product / Services
We offer a complete product range of Mechanical Vibrations Unit, Sedimentation Tank, Fiber Optics Trainer, Reflex Klyston Microwave Test Bench and Microwave Test Bench
Simple Pendulum Features Low cost, effective teaching Self-contained Wall mounted Determination of acceleration due to gravity Verification of equation of motion Three year warranty Range of Experiments To determine the gravitational acceleration 'g' To show that the periodic time of swing is proportional to the square root of the pendulum length Description A simple pendulum consisting of a cord with a ring at the top end and a sliding heavy bobweight. The pendulum oscillates on a knife edge bracket attached to the wall at a convenient height. A stopwatch and rule are supplied to time the swing of the pendulum and to measure its length. This equipment is part of a range designed to both demonstrate and experimentally confirm basic engineering principles. Great care has been given to each item so as to provide wide experimental scope without unduly complicating or compromising the design. Each piece of apparatus is self-contained and compact. Setting up time is minimal, and all measurements are made with the simplest possible instrumentation, so that the student involvement is purely with the engineering principles being taught
Separation In Sedimentation Tanks Technical Description In sedimentation tanks, solids are separated out of suspensions under the influence of gravity. For this, the density of the solid particles must be greater than that of the liquid. With , the factors influencing the separation process in sedimentation tanks can be investigated. First a suspension of water and whiting is prepared in a tank. A pump delivers the suspension to the sedimentation tank. In the inlet area of the sedimentation tank the suspension intermingles with fresh water. The mixture flows over an inlet weir. On their way through the sedimentation tank the solids sink to the bottom. The clarified water flows out by way of the weir at the tank outlet. The solid concentrations at the tank inlet and outletare determined by means of two Imhoff hoppers. The mass separated in the tank can be determined from the difference between them. The flow rates of the suspension and the fresh water are adjusted by valves and indicated by flow meters. This enables the mixing ratio - and thus the solid concentration of the mixture - to be adjusted. In order to ensure a uniform mix of the suspension and prevent premature sedimentation, a portion of the suspension is fed back into the tank by way of a bypass. To investigate the flow conditions, ink can be added with a piston burette to the fresh water stream as a tracer substance. The mixed-in volume of ink is entered using keys and indicated on a display. To provide enhanced observation of the flow conditions and settling processes, the sedimentation tank is made of transparent material. A baffle plate can be positioned in the tank to impede the flow. Its horizontal and vertical positioning in the tank is adjustable. This enables the flow conditions and the efficacy of the separation process to be influenced. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.
Automatic Flushing Tank Properly constructed transparent working model. Completeon heavy metal base and provided with over head tank, syphon, float, chain and outlet pipe.
Sedimentation Tank With mechanical sludge scraping and collecting devices. Theproperly constructed model is rectangular In shape, showinginfluent, offluent, scum collector, sludge hopper, sludge pipewith sluice valve. Carriage Is fitted with scrapper andskimmer and with tilting devices.
Reflex Klyston Microwave Test Bench To Study the Characteristic of Reflex Klyston. To Study the frequency, guide wavelength & free space wave length. To measureSWR & reflection co- efficient. To measureimpedance of a load.
|
Component Name |
Qty. |
|
Klystron power supply |
1 |
|
Klystron Tube |
1 |
|
Frequency Meter |
1 |
|
Slotted Section |
1 |
|
Detector Mount |
1 |
|
Matched Termination |
1 |
|
Wave Guide Stands |
1 |
|
BNC Cable |
1 |
|
Fixed Short |
1 |
|
Klystron Mount |
1 |
|
Isolator |
1 |
|
Variable Attenuator |
1 |
|
Tunable Probe |
1 |
|
Movable Short |
1 |
|
VSWR Meter Solid State |
1 |
|
SS Tuner |
1 |
|
Cooling Fan |
1 |
Microwave Test BenchOur customers can avail from us quality range of microwave test bench that is low on cost and high on performance. These test benches are precision-made microwave systems that use standard type rectangular wave-guide components to illustrate the essential elements of this field for study. Our range finds application in academic institutions, educational centers and research institutes.
Fiber Optics Trainer Fiber optic LED's having peak wavelength of Emission 660mm Inbuilt Signal Source : Analog & Digital - Bandwidth : 350KHz - Digital Bandwidth : 2.5MHz - Filters Transmitter : 02 nos. Receiver: 02 Nos. Fiber Optic Photo Detector. Modulation Techniques: - Amplitude Modulation, Frequency Modulation & Pulse width Modulation Drivers : 2 nos. with Analog & Digital modes. Analog : 02 nos. 4th order Butterworth Filter. Cut Off Frequency 3.4 KHz Onboard .Angle : Better than 60 Fiber Dia : 1000mu. Outer Dia. : 2.2mm .